Dimensions
Ordering Code
Curves
OFC - VILLA ofc@ofc-hydraulics.com - www.ofc-hydraulics.com
Hydraulic Symbol
3 WAY PRIORITY VALVE
EXCESS TO LINE
Pressure (bar)
250 200 150 100 50 0 50 100 150 200 250
Regulated Flow (lpm)
30
25
20
15
10
5
0
S > P
Size 02
P > S
Pressure (bar)
Pressure (bar)
250 200 150 100 50 0 50 100 150 200 250
250 200 150 100 50 0 50 100 150 200 250
Regulated Flow (lpm)
Regulated Flow (lpm)
90
75
60
45
30
15
0
60
50
40
30
20
10
0
S > P
S > P
Size 04
Size 03
P > S
P > S
PVEL - -
Size BSP
02 3/8
03 1/2
04 3/4
Ordering Code Example: PVEL03 = 1/2 BSP.
Size
02 03 04
Max Pressure (bar)
260 260 260
Max Inlet Flow (lpm)
50 85 150
Max Adjustment Flow (lpm)
40 60 90
Materials: Aluminium body, hardened steel inner parts.
+
0
*
9
=
&
'
)
/
1
4
3
6
(
:
Size
E-P-S
BSP
ABCDFGHMN
max
Q R T V Z Weight
kg
02 3/8 130 33 27,5 50 35 10 8,5 22 42,7 35 12 80 10 34 2,78
03 1/2 130 33 27,5 50 35 10 8,5 22 42,7 35 12 80 10 34 2,71
04 3/4 155 55 31,5 47 50 20 8,5 22 38 55 12 100 15 34 5,55
PVEL
Features
Page
140/00