SOLENOID CONTROLLED PILOT OPERATED DIRECTIONAL VALVE
SW-G04 SERIES
FEATURES
Armature operates in system oil. Impact is decreased and cushioning
added, making noise lowered & solenoid life Prolonged.
Wet armature solenoid eliminates push pin seal, reducing seal wear or
leakage for longer valve life.
Molded coil gives maximum insulating properties. They are protected by
a special resin and impervious to moisture and dirt for ease of
maintenance.
Plug-in solenoid, easy to change coil.
Change of pilot and drain can be easily accomplished by plugging or
unplugging.
Spool is designed to avoid creating jet flow or turbulence under high
pressure and flow.
HOW TO ORDER
SW-G04-C2-ET-A220-10-AB-K
K: WITH KNOB
NO CODE: WITHOUT KNOB
NO CODE: STANDARD TYPE
AB: WITH STROKE ADJUSTMENT BOTH ENDS
A: WITH STROKE ADJUSTMENT PORT A END
B: WITH STROKE ADJUSTMENT PORT B END
WIRING:
10: WITH JOINTION BOX WITH INDICATING LIGHT
20: HIRSCHMANN TYPE WITH INDICATING LIGHT
COI L VOLTAGE:
A240: AC240V, 60Hz; AC220V, 50Hz
A220: AC220V, 60Hz; AC200V, 50Hz R220: AC220V 50/60Hz
A120: AC120V, 60Hz; AC110V, 50Hz
A110: AC110V, 60Hz; AC110V, 50Hz R110: AC110V 50/60Hz
D24: DC24V
D12: DC12V
T: EXTERNAL DRAIN (See page 2/8)
NO CODE: FOR STANDARD INTERNAL DRAIN TYPE
E: EXTERNAL PILOT (See page 2/8)
NO CODE: FOR STANDARD INTERNAL PILOT TYPE
SPOOL TYPE
(
(See Application Common Data)
NOMINAL SIZE: 1/2” (D07)
SUBPLATE MOUNTED
HIGH PRESSURE HIGH FLOW SOLENOID DIRECTIONAL VALVE
1/8
SOLENOID CONTROLLED PILOT OPERATED DIRECTIONAL VALVE
SW-G04 SERIES
SPECIFICATIONS
Maximum operating pressure
315 kgf/cm
2
(4500 PSI)
210 kgf/cm
2
(3000 PSI) externally drained
Maximum tank line back pressure
140 kgf/cm
2
(2000 PSI) internally drained
Min. 8 kgf/cm
2
(113 PSI)
Pilot pressure
Max. 250 kgf/cm
2
(3550 PSI)
Maximum flow
300 LPM (80 GPM)
SW-G04-C,D SERIES 8.2 kgs (18 lbs)
Weight
SW-G04-B, SERIES 7.9 kgs (17.5 lbs)
OPTION ET
2/8
SOLENOID CONTROLLED PILOT OPERATED DIRECTIONAL VALVE
SW-G04 SERIES
SOLENOID RATINGS
VOLTAGE (V)
CURRENT & POWER
AT RATED VOLTAGE
ELECTRIC
SOURCE
COIL
TYPE
SOURCE
RATED
H
Z
RANGE
IN-RUSH
CURRENT (A)
HOLDING
CURRENT (A)
WATTAGE
AC100V 50 90-110 1.6 0.46
AC100V 90-110 1.4 0.36
A110
AC110V
60
99-121 1.5 0.39
AC110V 50 99-121 1.3 0.38
A120
AC120V 60 108-132 1.2 0.27
AC200V 50 180-220 0.80 0.23
A220
AC220V 60 198-242 0.75 0.19
AC220V 50 198-242 0.67 0.19
A.C.
A240
AC240V 60 216-264 0.59 0.13
D12 DC12V 10.8-13.2 2.2 2.2
D.C.
D24 DC24V 21.6-26.4 1.1 1.1
26
TECHNICAL DATA:
Solenoid can be used within 10% to + 10% of the rated voltage of the coil.
Withstand voltage 1500 v/sec.
Insulation resistance over 100M.
A momentary signal of approx 0.1 second is required for shifting action.
Pilot pressure of internally drained valves must always exceed tank port pressure by a minimum of 8.0 kgf/cm
2
(113 PSI)
Valve must be externally drained if there is a possibility of tank line persuader surges overcoming this differential.
Open center spools C3, C5, C6, C60 must be externally piloted.
ACCESSORIES:
Mounting bolt kits are supplied with valve socket head cap screws
M6 x 45 L 2 pieces (1/4" 20 UNC 2B x 1 3/4"L) for tightening torque 120-150 kgf-cm.(104-130 lbs-in).
M10 x 50 L 4 pieces (3/8" 16 UNC-2B x 2"L) for tightening torque 580-720 kgf-cm.(502-624 lbs-in).
O-ring P22A 90° 4 pieces, P9 90 ° 2 pieces.
3/8
SOLENOID CONTROLLED PILOT OPERATED DIRECTIONAL VALVE
SW-G04 SERIES
THE MAXIMUM FLOW RATE LPM (GPM) UNDER DIFFERENT PRESSURE kgf/cm
2
(PSI)
SPRING CENTERED
SPOOL TYPE
NORMAL POSITION
50kgf/cm
2
(
735 PSI
)
100 kgf/cm
2
(
1470 PSI
)
150 kgf/cm
2
(
2200 PSI
)
210 kgf/cm
2
(
3000 PSI
)
250 kgf/cm
2
(
3675 PSI
)
315 kgf/cm
2
(
4500 PSI
)
300(80.0) 300(80.0) 300(80.0) 260(69.3) 200(53.3) 140(37.3)
C2
300(80.0) 300(80.0) 260(69.3) 155(41.3) 120(32.0) 110(29.3)
C3
300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0)
300(80.0) 300(80.0) 300(80.0) 260(69.3) 245(65.3) 160(42.7)
C4
300(80.0) 300(80.0) 260(69.3) 185(49.3) 140(37.3) 110(29.3)
300(80.0) 300(80.0) 300(80.0) 260(69.3) 200(53.3) 145(38.7)
C40
300(80.0) 300(80.0) 260(69.3) 155(41.3) 120(32.0) 110(29.3)
C5
260(69.3) 255(68.0) 250(66.6) 245(65.3) 240(64.0) 240(64.0)
C6
300(80.0) 300(80.0) 265(80.0) 255(68.0) 245(65.3) 235(62.7)
300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0)
C60
300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0)
C7
300(80.0) 300(80.0) 300(80.0) 290(80.0) 280(74.7) 255(68.0)
300(80.0) 300(80.0) 285(76.0) 230(61.3) 170(45.3) 135(36.0)
C8
300(80.0) 300(80.0) 255(68.0) 165(44.0) 120(32.0) 110(29.3)
C9
300(80.0) 300(80.0) 270(72.0) 200(53.3) 160(42.7) 140(37.3)
LIST OF SPOOL FUNCTION
NOTE: The upper-side number in table describes the maximum flow for standard type.
The lower-side number in table describes the maximum flow for shock-less type.
4/8
SOLENOID CONTROLLED PILOT OPERATED DIRECTIONAL VALVE
SW-G04 SERIES
THE MAXIMUM FLOW RATE LPM (GPM) UNDER DIFFERENT PRESSURE kgf/cm
2
(PSI)
NO SPRING
SPOOL TYPE
NORMAL POSITION
50kgf/cm
2
(
735 PSI
)
100 kgf/cm
2
(
1470 PSI
)
150 kgf/cm
2
(
2200 PSI
)
210 kgf/cm
2
(
3000 PSI
)
250 kgf/cm
2
(
3675 PSI
)
315 kgf/cm
2
(
4500 PSI
)
N2
300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0)
N3
300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0)
N4
300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0)
N40
300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0)
THE MAXIMUM FLOW RATE LPM (GPM) UNDER DIFFERENT PRESSURE kgf/cm
2
(PSI)
SPRING OFFSET
SPOOL TYPE
NORMAL POSITION
50kgf/cm
2
(
735 PSI
)
100 kgf/cm
2
(
1470 PSI
)
150 kgf/cm
2
(
2200 PSI
)
210 kgf/cm
2
(
3000 PSI
)
250 kgf/cm
2
(
3675 PSI
)
315 kgf/cm
2
(
4500 PSI
)
B2
300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0)
B3
300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0)
B4
300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0)
B40
300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0)
LIST OF SPOOL FUNCTION
5/8
SOLENOID CONTROLLED PILOT OPERATED DIRECTIONAL VALVE
SW-G04 SERIES
PRESSURE DROP AND PERFORMANCE CURVES
TEST CIRCUIT
TEST SYSTEMS
1. Testing Valve
2. Pump
3. Pressure sensor
4. Flow sensor
5. Relief valve
6. Throttle valve
TEST CONDITIONS
Pressure: 70 kgf/cm
2
(1000 PSI)
Flow Rate: 300 LPM(80 GPM)
Viscosity: 35 cSt
CONTRAST CHART BETWEEN FACTORS AND VISCOSITIES
Pressure Drop Curve Number
SPOOL
TYPE
P
A B
T P
B A
T P
T
C2
5 4 5 6
C3
5 3 5 5 7
C4
5 3 5 5
C40
5 4 5 6
C5
7 4 5 5 5
C6
5 3 5 6 1
C60
7 5 7 7 2
C7
5 4 5 6
C8
5 4 5 5
C9
6 4 5 6
PERFORMANCE CURVES
cSt 15 20 30 40 50 60 70 80 90 100
VISCOSITY
SSU 77 98 141 186 232 278 324 371 417 464
FACTOR(G
)
0.81 0.87 0.96 1.03 1.09 1.14 1.19 1.23 1.27 1.30
The pressure drop ( P) can be obtained from the formula
P = P(G/0.85) for other specific gravity (G).
6/8
SOLENOID CONTROLLED PILOT OPERATED DIRECTIONAL VALVE
SW-G04 SERIES
INSTALLATION DIMENSIONS
Mounting Surface: ISO 4401-AD -07 - 4 -A
UNIT: mm(inch)
SW-G04- ∗∗∗ ∗∗ ∗∗∗∗ 10
7/8
SOLENOID CONTROLLED PILOT OPERATED DIRECTIONAL VALVE
SW-G04 SERIES
INSTALLATION DIMENSIONS
Mounting Surface: ISO 4401-AD -07 - 4 -A
UNIT: mm( inch)
SW-G04 ∗∗∗ ∗∗ ∗∗∗∗ 10 AB K