E
E-2
Solenoid Valve
SS-G01 SS-G03
AC Solenoid
DC Solenoid
AC Solenoid
DC Solenoid
Built-in Rectifier Built-in Rectifier
C* E* D* C* E* D*
Maximum
Working
Pressure
P, A, B ports 35(25)MPa{357(255)kgf/cm
2
}(Note1)
Maximum
Allowable
Backpressure
T port 21MPa{214kgf/cm
2
} 16MPa{163kgf/cm
2
}
Switches/min.
Standard Type
300
120
300 300
120
240
Shockless Type
−
120
−
120
Standard
Indicator light R R
Option
Shockless
−
F
−
F
Surgeless G
−
G G
−
G
With manual push-button
N N
Quick Return
−
Q
− −
Q
−
Weight
(kg)
Double Solenoid 1.8 2.0 4.2 5.5
Single Solenoid 1.4 1.5 3.5 4.1
Operating
Environment
Dust Resistance/Water Resistance Rank
JIS C 0920 IP64 (Dust-tight, Splash-proof)
Ambient Temperature
−
20 to 50°C
Operating
Fluid
Temperature Range
−
20 to 70°C
Viscosity Range 15 to 300mm
2
/s
Filtration 25 microns or less
Mounting bolt
Size
×
Length M5 × 45 (Four)
M6 × 70 (Four)
(M8 × 70 (Four))
Tightening Torque M5 5 to 7N
.
m{51 to 71kgf
.
cm}
M6 10 to 13N
.
m{102 to 133kgf
.
cm}
(M8 20 to 25N
.
m{204 to 255kgf
.
cm})
Note) 1. Maximum operating pressure depends on the valve type. For details, see page E-1.
2. For mounting bolts, use 12T or equivalent.
3. Mounting bolts are not included with the 01 size. Bolts are included with the 03 size.
¡Handling
z
In order to realize the full benefits of the
wet type solenoid valve, configure piping
so oil is constantly supplied to the T(R)
port. Never use a stopper plug in the T(R)
port.
x
Ensure that surge pressure in excess of
the maximum allowable back pressure
does not reach the T port.
c
Note that the maximum flow rate is limited
when used as a four-way valve, or by
blocking ports for use as a two-way valve
or one-way valve.
v
Always keep the operating fluid clean.
Allowable contamination is class NAS12
or less.
b
When using petroleum type operating
fluid, use JIS K 2213 Class 1 or Class 2,
or equivalent.
n
For details about using fire-resistant
hydraulic fluid, see page D-1 for more
information.
m
Use this valve only within the allowable
voltage range.
,
Do not allow the AC solenoid to become
charged until you install the coil into the
valve.
.
In the case of operation symbols A2X,
H2X, and E2X, run drain piping from the
valve T port.
⁄0
Maintaining a switching position under
high pressure for a long period can cause
abnormal operation due to hydraulic lock-
up. Contact your agent when you need to
maintain a switching position for a long
period.
⁄1
When using a detent type (E2X, 3X, E3Z),
use constant energization in order to
securely maintain the switching position.
⁄2
Note that manual pin operating pressure
changes in accordance with tank line back
pressure.
⁄3
The series described in the table below
are available for use as RSS and RIS
Series solenoid control relief valves.
⁄4
The coil surface temperature increases if
this valve is kept continuously energized.
Install the valve so there is no chance of it
being touched directly by hand.
⁄5
Use the following table for specification
when a sub plate is required.
15
RSS-***-AR*-(H)-**-
23
RIS-***-AR*-(H)-**-21
SS-G01-AR-R-**-31
15
RSS-***-AQ*-(H)-**-
23
RIS-***-AQ*-(H)-**-21
SS-G01-A3X-R-**-31
15
RSS-***-*-F(H)-**-
23
SS-G01-A8X0-R-**-31
RIS-***-*-F-**-21 SS-G01-A3X-R-**-31
Model No.
Pipe
Diameter
Maximum Working
Pressure
MPa{kgf/cm
2
}
Recommended
Flow Rate
(r/min)
Weight
(kg)
Applicable Valve Type
MSA-01X-10 1/4
25{255}
20
1.2 SS-G01-**-R-**-31
MSA-01Y-10 3/8 40
MSA-03-10 3/8 45
2.3 SS-G03-**-R-**-J21
MSA-03X-10 1/2 80
MS-03-30 3/8 45
2.3 SS-G03-**-R-**-21
MS-03X-30 1/2 80
E Solenoid Valve(P01-12)_E.q 03.11.21 5:38 PM Page 2