E
E-46
Solenoid Valve
FINE SOLENOID VALVE
Fine Solenoid Valve
SF Series
10 to 40
rr
/min
21MPa
q
The function of two valves in one
A two-speed controller provides smooth
speed adjustment from low speed to high,
and from high-speed to low.
w
Quiet starts and stops
A low-speed startup and stop feature
makes startups and stops smooth and
soft.
e
Separate control of forward and back
cylinder movement
There are five volume settings for high-
speed flow rate and acceleration/deceler-
ation times that can be independently
adjusted SOL.a and SOL.b (ON side,
OFF side).
¡Handling
z
Valve differential pressure
Volume adjustment becomes sensitive
when P
→
A (B) and B(A)
→
T differential
pressure is large. Maintain the pressure dif-
ferential so it is no greater than 3.5MPa
{35.7kgf/cm
2
}.
x
Low-speed flow rate
The spool may not move if the low-speed
flow rate is below the minimum. Use this
valve only within the allowable minimum
low-speed flow rate range.
c
Deceleration circuit
¡
Use a C5** spool for the deceleration
circuit. Deceleration is difficult with the
C6S** spool.
¡
When large deceleration is required or
for a system that uses a vertical cylin-
der, equip an external drain type
counter balance valve. See the illustra-
tion below.
v
Pilot check circuit
¡
For a circuit with a pilot check valve,
knocking may occur in the pilot check
valve due to large load inertia and circuit
pressure loss. In cases like this, use an
external drain type pilot check valve. See
the illustration below.
b
Environmental conditions
¡
The IC circuit board is located inside the
central control box, so care must be
exercised concerning water-resistance
and ambient temperature.
•
Water: Cover the box so there is no
direct splashing with water.
•
Ambient Temperature: Use in an area
where the temperature is 5°C to 50°C.
n
Operating Fluid
¡
Always keep the operating fluid clean.
Allowable contamination is class NAS11
or less.
¡
Use oil-based hydraulic operating fluid.
¡
Contact your agent when you want to
use fire-resistant hydraulic fluid.
(Continued on following page)
10– D2 – R – C – G01 – SF
Design number
Power supply D2: 24V DC
Auxiliary symbol
None: Sink
A: Source
Maximum flow rate: 10, 20, 40 /min
Center position: 5,6S
Operation Method: C (Spring center)
With indicator light
Mounting method G: Gasket type
Nominal diameter: 01 (01 size)
Fine solenoid valve
Note) 1.The above high-speed and low-speed flow rates are obtained with a differential pressure
(PA, PB) of 1.0MPa {10.2kgf/cm
2
}. The flow rates depend on differential pressure.
2.Hysteresis and repeatability values are those at maximum flow rate.
3.For mounting bolts, use 12T or equivalent.
4.Mounting bolts are not included.
Features
When large brake pres-
sure is required
(Use an external drain
type counter valve.)
When there is the possibil-
ity of pilot check valve
knocking
(Use an external drain
type pilot check valve.)
Specifications
Model No.
Item
SF-G01
-C*10-D2-10
SF-G01
-C*20-D2-10
SF-G01
-C*40-D2-10
Valve Maximum Operating Pressure MPa{kgf/cm
2
}
21{214}
Maximum Flow Rate R/min(Note1)
10 20 40
High-speed Flow Rate R/min(Note1)
5 to 10 10 to 20 20 to 40
Low-speed Flow Rate R/min(Note1)
0.5 to 4 2 to 8 4 to 16
Maximum Allowable Pressure MPa{kgf/cm
2
}
7{71}
Acceleration/Deceleration Time Adjustment Range SEC
0.1 to 2
Hysteresis (Note 2) 7%
Repeatability (Note 2) 3%
Power Supply Voltage V D2: 24V DC regulated DC power supply
Maximum Power Consumption W
36W
Operating
Environment
Dust Resistance/Water Resistance Rank
JIS C0920 IP63 (Dust-tight, Rain-proof)
Ambient Temperature
5 to 50°C
Operating
Fluid
Temperature Range
5 to 60°C
Viscosity Range
15 to 300mm
2
/s
Filtration 25 microns or less
Mounting
bolt
Size x Length M5 x 45 (four)
Tightening Torque 5 to 7N-m{51 to 71kgf-cm}
Understanding Model Numbers