Modular Valves
D
D-28
PRESSURE REDUCING MODULAR
VALVE
Pressure Reducing
Modular Valve
40 to 300
rr
/min
25,35MPa
Features
qThis modular valve makes the pressure
in part of the circuit lower than that of
the main circuit.
wEven when pressure changes in the
primary main circuit, the reduced sec-
ondary pressure is maintained at a
constant level.
eMaximum Operating Pressure: 25,
35MPa {255, 357kgf/cm
2
}
Specifications
Model No.
Nominal
Diameter
(Size)
Maximum
Working Pressure
MPa{kgf/cm
2
}
Maximum
Flow Rate
r/min
Pressure Adjustment
Range
MPa{kgf/cm
2
}
Weight
kg
Gasket Surface
Dimensions
OG-G01-PC-21
P1
P2
1/8
25
{255}
50
0.15 to 3.5{ 1.5 to 35.7}
0.8 to 7{ 8.2 to 71.4}
3.5 to 16{35.7 to 163}
1.3 ISO 4401-03-02-0-94
OG-G03-PC-(V)-J51
P1
P3
3/8
25
{255}
80
but C : 50
0.25 to 3.5{ 2.5 to 35.7}
0.8 to 7{ 8.2 to 71.4}
3.5 to 21{35.7 to 214}
3.8 ISO 4401-05-04-0-94
OGH-G04-P1-10
P3
1/2
35
{357}
300
0.8 to 7{ 8.2 to 71.4}
3.5 to 25{35.7 to 255}
8.0 ISO 4401-07-06-0-94
z
When using a remote control valve in a
vent circuit, certain vent circuit pipe
capacities can cause vibration. Because
of this, thick steel pipe with an inside
diameter of
φ
4mm that is no longer than
three meters is recommended. Vent pip-
ing cannot be used with the 01 size. If a
vent port is required for the 03 size, add
the auxiliary code "V".
x
For the 03 size, the drainage can be
allowed to escape through the T port. In
the case of a valve with the auxiliary sym-
bol B, however, run a return pipe from the
drain discharge port directly to the tank.
c
With the 04 sizes, piping is not required
because drainage can be allowed to
escape from the gasket side drain port. In
the case of a valve with the auxiliary sym-
bol B, however, run a return pipe from the
drain discharge port directly to the tank.
v
Note that a change in drain back pressure
causes a change in setting pressure.
b
With the 01, 03 sizes, the flow rate is limit-
ed at low pressures. See the Pressure-
Flow Rate Characteristics on pages D-30
for more information.
nNote that a sub plate and installation bolts
are not included. See pages D-90 through
D-95 if these items are required.
m
04 series modular valves do not have an
L (DR
2
) drain port, so they cannot be used
in combination with pressure center type
solenoid valves (D).
,
With the 03, 04 sizes, the control port can
be changed by altering the attachment ori-
entation of the back cover. See the instal-
lation diagram for more information. After
making this change, be sure also to make
the other changes in accordance with the
model number indicated on the name-
plate.
J51–(B)–1P–03G–OG
Pressure adjustment range C, 1, 2, 3
Control port P: P port
Nominal diameter (size) 01, 03
Mounting method G: Gasket type
Pressure reducing modular valve
Design number Note: For 03 size, relationship between mounting bolts and
design number is indicated as J51: M6, 51; M8.
Auxiliary symbol B: See notes 2 and 3 under "Handling."
K: With handle (01, 03 size)
V: With vent port (03 size)
Understanding Model Numbers
01, 03, size
¡Handling