VDS SERIES SMALL VARIABLE
VOLUME VANE PUMP
VDS Series
Small Variable Volume Vane Pump
0.5in
3
/rev
4.0gpm
1000psi
V-1
qHigh efficiency operation
with minimal power loss
All the performance of the original
n e w V D R s e r i e s m e c h a n i s m s
combines with precision machin-
i n g f o r a p u m p t h a t m i n i m i z e s
power loss, especially at full cut-
off.
wQuiet operation
Jo urnal be aring s w ith a p roven
record on IP pumps plus new suc-
tion and discharge port configura-
tions reduce operating noise and
deliver quiet operation with mini-
mal vibration, ev en in th e h igh-
pressure range.
eCompact and simple
design, easy operation
Compact and quiet, VDS Series
variable vane pumps are economi-
cal and easy to handle. A simple
design allows use in a wide range
of hydraulic systems.
rPrecise characteristics,
prompt response
Prompt response at both ON-OFF
and O F F-O N e n su r es i ns t ant a-
neous, stable, high-precision oper-
ation.
tSolidly built for high effi-
ciency and long life
VDS S e rie s p ump s a re b ui l t t o
last, with a design that incorpo-
rates years of NACHI experience
and know-how. Specially selected
ma te ri al s a nd skilled w or km an-
ship provide outstanding durability
along with stable, high-efficiency
operation.
¡Handling
zT h e di re c t i o n of r ot at io n f or t hi s
pump is clockwise (rightward) when
viewed from the shaft side.
xDrain piping must be direct piping up
to a point that is below the tank fluid
level, and back pressure due to pipe
r e s i s t a n c e s h o u l d n o t e x c e e d
0.03MPa.
cWhen adjusting pressure, pressure
is i nc re a se d by c lo ck w is e (r ig ht-
ward) rotation of the adjusting screw
and decreased by counterclockwise
(leftward) rotation.
vWhen a d justing t h e flow ra t e , the
flow rate is decreased by clockwise
(rightward) rotation of the adjusting
sc re w a nd i n cr ea s ed b y c ou n te r-
clock w i se (lef t w ard) rot a tion. Th e
graph on the right provides general
g u i d e l i n e s f o r t h e r e l a t i o n s h i p
between t he rotation a ngle of the
flow rate adjusting screw and the no-
load discharge rate.
bF ac t o r y D ef a u l t P -Q S e t t i ng s
(Standard Model)
•
Flow Rate Setting = Maximum flow
rate for model as indicated in the
catalog
•
Pressure Setting = Pressure shown
in table below
However:Q=q × n × 10
−3
Q : No-load Discharge Rate (r/min)
q : Capacity (cm
3
/rev)
N : Revolution Speed min
−1
Th e v al ue s i nd i ca te d a bo ve ar e a t
m ax i m um p u m p d i s c h a r g e v o lu m e
with the flow volume adjusting screw
at the 0° position.
The broken line shows the flow volume
adjustment range lower limit value.
nThrust Screw
The thrust screw is precision adjust-
ed at the factory during assembly.
Never touch the thrust screw.
See callout 9 in the cross-section
diagram on page V-4.
mInitial Operation
Before operating the pump for the
first time, put the pump discharge
side into the no-load state and then
repeatedly start and stop the motor
to bleed all air from inside the pump
and the suction piping. After confirm-
ing that the pump is discharging oil,
continue the no-load operation for at
least 10 minutes to discharge all the
air from the circuit.
,For the hydraulic operating fluid, use
an R&O type and wear-resistant type
of ISO VG32 to 68 or equivalent (vis-
co si ty in de x o f at le as t 9 0) . U se
hydraulic operating fluid tha t pro-
v id e s k i n e m a ti c v i s c os i ty d u ri n g
o pe r a ti o n in t he r an g e of 2 0 t o
150mm
2
/s.
.The operating temperature range is
15 to 60°C. When the oil temperature
at startup is 15°C or less, perform a
warm-up operation at low pressure
un t il th e oi l t e mpe rat ure rea che s
15°C. Use the pump in an area where
the temperature is within the range
of 0 to 60°C.
(Continued on following page)
Features
Specifications
0.61
0.48
0.36
0.24
0.18
0.12
3
Pump capacity q in /rev
Factory Default
Pressure Settings
MPa{psi}
1 : 2.0 {286}
2 : 3.5 {500}
3 : 7.0 {1000}
Model
Delivery
(r/min (gpm) at No-Load)
Pressure
Adjust Range
kgf/cm
2
(psi)
Drive Speed (rpm)
Max. Setting
Pressure
kgf/cm
2
(psi)
Weight
kgf (rbs)
Foot Mounting Flange Mounting 1800rpm 1500rpm Minimum Maximum
VDS-OA-1A1-E11 VDS-OB-1A1-E11
15
(4.0)
12.5
(3.3)
10
~
20
(143
~
286)
800 1800
20
(286)
A-type 6.5
(14.3)
B-type 4.5
(9.9)
VDS-OA-1A2-E11 VDS-OB-1A2-E11
15
~
35
(214
~
500)
35
(500)
VDS-OA-1A3-E11 VDS-OB-1A3-E11
30
~
70
(429
~
1000)
70
(1000)