13.11
Ordering code
)ORZ30 l/min
0D[ZRUNLQJSUHVVXUH 300 bar
/HDNDJH0,25 cc/min
6HDOV NBR
&DYLW\C220000
&DUWULGJHWKLJKWHQLQJWRUTXH30 Nm
5LQJQXWWKLJKWHQLQJWRUTXH 5 Nm
:HLJKWZLWKFRLO0,32 Kg
)LOWHU280 micron
&RLOCT-9300 to be ordered separately
0 5 6 2 5 0 0 0
1
0
0
4 5
0562.5 NA
Cartridge SAE 8
0 5 10 15 20 25 30 35
350
300
250
200
150
100
50
0
0 5 10 15 20 25 30 35 40 45
20
16
12
8
4
0
1
2
www.nem-hydraulics.com
5.01.021/A
:LWKRXW¿OWHU
:LWK¿OWHU
No emergency
Push
Button
Push and
Twist
1 = Application limits from 2 to 1
2 = Application limits from 1 to 2
 3UHVVXUHGURSIURPWRZLWKRXW¿OWHU
 3UHVVXUHGURSIURPWRZLWK¿OWHU
Pressure [bar]
Flow [l/min]
Pressure [bar]
Flow [l/min]
2 WAYS 2 POSITIONS ELECTRIC VALVE, PILOT POPPET OPERATED NO
42
62,7
27,5
Ø 12,7
1
2
20,50
81)$
Hex.24
1
2
2
1