13.11
Ordering code
Cartridge SAE 8
0 4 6 2 2 0 0 0 0
S2S1
0462.2
0 2 4 6 8 10
16
12
8
4
0
0 2 4 6 8 10 12
250
200
150
100
50
0
3
4
2
1
www.nem-hydraulics.com
5.01.058
)ORZ10 l/min
0D[ZRUNLQJSUHVVXUHLQ 210 bar
0D[ZRUNLQJSUHVVXUHLQ 20 bar
/HDNDJH60 cc/min
6HDOV NBR
&DYLW\ C420000
&DUWULGJHWKLJKWHQLQJWRUTXH 30 Nm
5LQJQXWWKLJKWHQLQJWRUTXH 5 Nm
:HLJKWZLWKFRLO0,70 Kg
&RLOCT-9400 to be ordered separately
Pressure [bar]
Flow [l/min]
Pressure [bar]
Flow [l/min]
2
1
1 = Pressure drop from 2/4 to 3
2 = Pressure drop from 3 to 2/4
Application limits from 3 in 2/4
4 WAYS 3 POSITIONS ELECTRIC ON/OFF SPOOL VALVE DIRECT ACTING
No emergency
Push
Button
0 4
45,2
103
53,4
Ø 12,6
1
2
Ø 15,8
3
Ø 14,2
4
S2
S1
81)$
Hex.24