REV
SIZE
B
APVD ENGRG
APVD PROD ENGRG
TITLE
DWN
X NO
SCALE
North Mankato, Minnesota USA
CUSTOMER COPY
DRAWING NUMBER
DRAWING NUMBER
NPI OR ECN NO
01-JAN-2012
R
TANK PORT
.95
24.2[ ]
4.03
102.4[ ]
2.12
53.8[ ]
.95
24.1[ ]
3.40
86.4[ ]
1.33
33.8[ ]
1.29
32.8[ ]
2.94
74.7[ ]
.95
24.1[ ]
2.25
57.2[ ]
.78
19.9[ ]
5.13
130.3[ ]
.75
19.1[ ]
1.53
38.9[ ]
2.87
72.9[ ]
2.250 .014
57.2 .3[ ]
.94
23.9[ ]
2.85
72.4[ ]
PART
NUMBER
DESCRIPTION REVISION
ALLOWABLE SYSTEM
RELIEF VALVE
PRESSURE (PSI [bar])
ACCUMULATOR
CHARGING LOW
LIMIT (PSI [bar])
ACCUMULATOR
CHARGING HIGH
LIMIT (PSI [bar])
ACCUMULATOR CHARGE
RATE (GPM [LPM])
INTERNAL
FILTRATION
REPAIR KIT
06-463-200 ACV-DMO11-128-159-10 H 2750#250 [189.6#17.2]1850#50 [127.6#3.4]2300#50 [158.6#3.4]2.7#0.5 [10.2#1.9] 54 MICRON OR BETTER 06-400-112
06-463-202 ACV-DMO11-155-190-10 G 3050#50 [210.3#3.4]2250#50 [155.1#3.4]2750#50 [189.6#3.4]2.7#0.5 [10.2#1.9] 54 MICRON OR BETTER 06-400-112
06-463-204 ACV-DMO11-114-138-10 H 2600#400 [179.3#27.6]1650#50 [113.8#3.4]2000#50 [137.9#3.4]2.7#0.5 [10.2#1.9] 54 MICRON OR BETTER 06-400-112
06-463-206 ACV-DMO11-86-124-10 G 2525#475 [174.1#32.8]1250#50 [86.2#3.4]1800#50 [124.1#3.4]2.7#0.5 [10.2#1.9] 54 MICRON OR BETTER 06-400-112
06-463-208 ACV-DMO11-117-145-10 H 2600#400 [179.3#27.6]1700#50 [117.2#3.4]2100#50 [144.8#3.4]2.7#0.5 [10.2#1.9] 54 MICRON OR BETTER 06-400-112
06-463-210 ACV-DMO11-103-128-10 H 2550#450 [175.8#31.0]1500#50 [103.4#3.4]1850#50 [127.6#3.4]2.7#0.5 [10.2#1.9] 54 MICRON OR BETTER 06-400-112
06-463-212 ACV-DMO11-86-103-10 E 2350#650 [162.0#44.8]1250#50 [86.2#3.4]1500#50 [103.4#3.4]2.7#0.5 [10.2#1.9] 54 MICRON OR BETTER 06-400-112
06-463-214 ACV-DMO11-64-83-10 F 2225#775 [153.4#53.4]925#50 [63.8#3.4]1200#50 [82.7#3.4]2.7#0.5 [10.2#1.9] 54 MICRON OR BETTER 06-400-112
06-463-216 ACV-DMO11-93-114-3 E 2450#550 [168.9#37.9]1350#50 [93.1#3.4]1650#50 [113.8#3.4].75#0.25 [2.8#.9] 54 MICRON OR BETTER 06-400-112
06-463-218 ACV-DMO11-95-124-6 E 2525#475 [174.1#32.8]1375#50 [94.8#3.4]1800#50 [124.1#3.4]1.7#0.5 [6.4#1.9] 54 MICRON OR BETTER 06-400-112
06-463-222 ACV-DMO11-148-179-10 E 2925#75 [201.7#5.2]2150#50 [148.2#3.4]2600#50 [179.3#3.4]2.7#0.5 [10.2#1.9] 54 MICRON OR BETTER 06-400-112
06-463-226 ACV-DMO11-86-103-3 E 2350#650 [162.0#44.8]1250#50 [86.2#3.4]1500#50 [103.4#3.4].75#0.25 [2.8#.9] 54 MICRON OR BETTER 06-400-112
06-463-228 ACV-DMO11-145-179-3 E 3050#50 [210.3#3.4]2100#50 [144.8#3.4]2600#50 [179.3#3.4].75#0.25 [2.8#.9] 54 MICRON OR BETTER 06-400-112
06-463-230 ACV-DMO11-114-138-6 E 2600#400 [179.3#27.6]1650#50 [113.8#3.4]2000#50 [137.9#3.4]1.7#0.5 [6.4#1.9] 54 MICRON OR BETTER 06-400-112
06-463-234 ACV-DMO11-138-166-6 E 2800#200 [193.1#13.8]2000#50 [137.9#3.4]2400#50 [165.5#3.4]1.7#0.5 [6.4#1.9] 54 MICRON OR BETTER 06-400-112
06-463-238 ACV-DMO11-124-152-19 C 2700#300 [186.2#20.7]1800#50 [124.1#3.4]2200#50 [151.7#3.4]5.0#1.0 [18.9#3.8] 54 MICRON OR BETTER 06-400-112
06-463-248 ACV-DMO11-114-138-6U B 2850#500 [196.5#34.5]1650#50 [113.8#3.4]2000#50 [137.9#3.4]1.7#0.5 [6.4#1.9] 100 MICRON NOMINAL 06-400-447
06-463-252 ACV-DMO11-45-60-6 A 2063#938 [142.2#64.7]650#50 [45#3.4] 875#50 [60.3#3.4]1.7#0.5 [6.4#1.9] 100 MICRON NOMINAL 06-400-485
06-463-254 ACV-DMO11-55-71-3 B 2138#862 [147.4#59.4]800#38 [55.2#2.6]1025#38 [70.7#2.6].75#0.25 [2.8#.9] 100 MICRON NOMINAL 06-400-485
ECN E000557
06-463-240
SEE CHART
K
2 1
06-463-240
2015-06-24
JJC
0.500
ACV-DMO
COPYRIGHT MICO, INC. ALL RIGHTS RESERVED.
WITHOUT WRITTEN PERMISSION FROM MICO, INC.
AND MAY NOT BE REPRODUCED OR DISCLOSED
THIS DOCUMENT IS PROVIDED IN CONFIDENCE
THE MATERIAL DISCLOSED IN THIS DOCUMENT.
MICO, INC CLAIMS PROPRIETARY RIGHTS TO
AN ACTUAL APPLICATION FOR WHICH SYSTEM WAS DESIGNED.
COMPONENTS AND SYSTEM AFTER TESTING PERFORMANCE ON
DESIGNER MUST MAKE FINAL ACCEPTANCE AND APPROVAL OF
USER AND/OR SYSTEM DESIGNER. THE POTENTIAL USER AND/OR
INC ARE BASED ON INFORMATION SUPPLIED BY POTENTIAL
COMPONENT AND SYSTEM RECOMMENDATIONS MADE BY MICO,
NOTES:
1) FOR USE WITH MINERAL BASE HYDRAULIC OIL.
2) DIMENSIONS MAY VARY BETWEEN UNITS AND ARE FOR REFERENCE
PURPOSES ONLY. MILLIMETER VALUES MAY NOT BE AN EXACT CONVERSION
OF INCH VALUES.
3) REPAIR KIT P/N: SEE CHART
4) SURFACE COATING: OLIVE DRAB PRIMER PER DOD-P-15328 SPECIFICATION.
PERFORMANCE CHARACTERISTICS:
1) SYSTEM RELIEF VALVE NOT INCLUDED.
2) RECOMMENDED SYSTEM FLOW 2 TO 30 GPM [7.6 TO 113.6 LPM].
3) FLOW THRU PRESSURE DROP IS APPROXIMATELY 70 PSI [4.8 bar] AT 15 GPM [56.8 LPM]
WITH 14 CENTISTOKE OIL.
4) EXTERNAL FILTRATION OF 10 MICRON OR BETTER IS REQUIRED.
2X MOUNTING HOLES
3/8-16UNC-B x.56 [14.2]MIN.
PRESSURE PORT (P)
#12 SAE O-RING PORT
PER SAE J1926/1: 1 1/16-12
SWITCH PORT (SW)
#8 SAE O-RING PORT
PER SAE J1926/1: 3/4-16
LOCATION OF P/N AND DATE CODE
ACCUMULATOR #1 PORT (A)
#8 SAE O-RING PORT
PER SAE J1926/1: 3/4-16
ACCUMULATOR #2 PORT
#8 SAE O-RING PORT
PER SAE J1926/1: 3/4-16
TANK PORT (T)
#8 SAE O-RING PORT
PER SAE J1926/1: 3/4-16
CAUTION: TAMPERING WITH SCREW
WILL CHANGE CHARGE LIMITSFLOW THRU PORT (O)
#12 SAE O-RING PORT
PER SAE J1926/1: 1 1/16-12
INCH
[MILLIMETER]
P O
T
A1 A2
SW
CL 2015-06-25
DPD 2015-06-30