FHB series
Maximum working pressure up to 32 MPa (320 bar) - Flow rate up to 485 l/min
High Pressure  lters
Please scan the QR codes to get updated electronic version of the related document:
INSTALLATION, SERVICE AND MAINTENANCE MANUAL AND SAFETY INSTRUCTIONS
FHB050 FHB320FHB065 FHB135
High Pressure  lters
561
GENERAL INFORMATIONFHB
- Head: Phosphatized cast iron
- Housing: Phosphatized steel
- Bypass valve: Steel
- Check valve: Steel
Filter housing materials
- Working pressure: 32 MPa (320 bar)
- Test pressure: 48 MPa (480 bar)
- Burst pressure: 96 MPa (960 bar)
- Pulse pressure fatigue test: 1 000 000 cycles
with pressure from 0 to 32 MPa (320 bar)
Pressure
From -25 °C to +110 °C
Temperature
- Opening pressure 600 kPa (6 bar) ±10%
- Other opening pressures on request.
Bypass valve
- Microbre lter elements - series N: 20 bar
- Microbre lter elements - series H: 210 bar
(not available for FHB050)
- Microbre lter elements - series S: 210 bar (only for FHB050)
- Wire mesh lter elements - series N: 20 bar
- Fluid ow through the lter element from OUT to IN
∆p element type
- Standard NBR series A
- Optional FPM series V
Seals
FHB lters are provided
for vertical mounting
Note
Manifold mounting
Connections
Weights [kg] and volumes [dm
3
]
Weights [kg]
FHB 050
FHB 065
FHB 135
FHB 320
Volumes [dm
3
]
Length Length
0.21
0.20
0.40
0.91
0.52
-
-
3.59
0.30
0.27
0.73
1.63
0.81
-
-
-
0.40
0.49
0.94
2.40
1 42 53
2.61
3.33
6.61
12.95
3.86
-
-
26.77
2.98
3.69
8.21
15.08
5.04
-
-
-
3.39
4.90
9.21
17.37
1 42 53
Filter series
High Pressure lters
Manifold
Maximum working pressure up to 32 MPa (320 bar)
Flow rate up to 485 l/min
FHB is a range of high pressure filter for protection of sensitive
components in high pressure hydraulic systems in the mobile machines.
They are directly connected to the side of the manifold, through the
proper anged interface.
Available features:
- Manifold connections up to Ø30 mm, for a maximum ow rate of 485 l/min
- Fine ltration rating, to get a good cleanliness level into the system
- Bypass valve, to relieve excessive pressure drop across the lter media
- Check valve, to protect the system against reverse ow
- Low collapse filter element “N”, for use with filters provided with
bypass valve
- High collapse lter element “H”, for use with lters not provided with
bypass valve
- High collapse lter element with external support “S”, for lter element
protection against the back pressure caused by the check valve in lters
not provided with the bypass valve
- Visual, electrical and electronic differential clogging indicators
Common applications:
Delivery lines, in any high pressure industrial equipment or mobile machines
Description Technical data
High Pressure lters
562
GENERAL INFORMATION FHB
Flow rates [l/min
]
Hydraulic symbols
Filter series
FHB 050
FHB 065
FHB 135
FHB 320
Style S Style B Style T Style D
1
2
3
4
5
1
2
3
FHB 050
FHB 065
1
2
3
4
FHB 320
1
2
3
FHB 135
Length
Length
Filter series
Filter series
Maximum ow rate for a complete pressure lter with a pressure drop ∆p = 1.5 bar.
The reference uid has a kinematic viscosity of 30 mm
2
/s (cSt) and a density of 0.86 kg/dm
3
.
For different pressure drop or uid viscosity we recommend to use our selection software available on www.mpltri.com.
You can also calculate the right size using the formulas present on the FILTER SIZING paragraph at the beginning of the full catalogue or at the beginning of the lter family brochure.
Please, contact our Sales Department for further additional information.
Filter element design - N Series
Filter element design - N Series
Filter element design - S Series
Filter element design - H Series
A03 A06 A10 A16 A25
A03 A06 A10 A16 A25
30 40 58 60 74
46 50 76 86 108
59 62 87 95 115
74 80 101 103 119
90 92 105 113 126
23 25 49 58 81
33 38 66 75 94
60 68 95 102 116
49 55 97 100 160
90 110 137 140 182
126 142 175 187 207
110 117 192 201 304
200 230 319 325 392
269 312 381 389 432
311 334 388 394 437
A03 A06 A10 A16 A25 M25
A03 A06 A10 A16 A25 M25
43 42 79 81 101 131
53 58 84 93 112 132
67 70 94 101 119 133
82 87 106 108 122 134
102 104 119 122 127 136
25 33 55 62 87 133
33 51 70 76 101 134
60 71 97 103 118 138
67 72 120 129 177 212
109 116 152 154 224 250
153 155 201 205 226 253
130 143 238 286 343 442
259 281 391 409 454 468
332 368 441 455 463 476
368 390 446 462 481 488
OUT
D.I.
IN
OUT
D.I.
IN
OUT
D.I.
IN
OUT
D.I.
IN
High Pressure lters
563
GENERAL INFORMATIONFHB
Pressure drop
The curves are plotted using mineral oil with density of 0.86 kg/dm
3
in compliance with ISO 3968. ∆p varies proportionally with density.
Filter housings ∆p pressure drop
Bypass valve pressure drop
0.90
0.60
0.30
0.00
0 40
80
120 160
200
0.90
0.60
0.30
0.00
0 20
40
60 80
100
FHB 050 - 065
0.90
0.60
0.30
0.00
0 75
150
225 300
375
FHB 135
FHB 320
266
15
10
5
0
0 18
36
54 72
90
15
10
5
0
0 12
24
36 48
60
FHB 050 - 065
FHB 135
15
10
5
0
0 50
100
150 200
250
FHB 320
Valves
Bypass valve pressure drop
0.90
0.60
0.30
0.00
0 40
80
120 160
200
0.90
0.60
0.30
0.00
0 20
40
60 80
100
FHB 050 - 065
0.90
0.60
0.30
0.00
0 75
150
225 300
375
FHB 135
FHB 320
266
15
10
5
0
0 18
36
54 72
90
15
10
5
0
0 12
24
36 48
60
FHB 050 - 065
FHB 135
15
10
5
0
0 50
100
150 200
250
FHB 320
Valves
Bypass valve pressure drop
0.90
0.60
0.30
0.00
0 40
80
120 160
200
0.90
0.60
0.30
0.00
0 20
40
60 80
100
FHB 050 - 065
0.90
0.60
0.30
0.00
0 75
150
225 300
375
FHB 135
FHB 320
266
15
10
5
0
0 18
36
54 72
90
15
10
5
0
0 12
24
36 48
60
FHB 050 - 065
FHB 135
15
10
5
0
0 50
100
150 200
250
FHB 320
Valves
Bypass valve pressure drop
0.90
0.60
0.30
0.00
0 40
80
120 160
200
0.90
0.60
0.30
0.00
0 20
40
60 80
100
FHB 050 - 065
0.90
0.60
0.30
0.00
0 75
150
225 300
375
FHB 135
FHB 320
266
15
10
5
0
0 18
36
54 72
90
15
10
5
0
0 12
24
36 48
60
FHB 050 - 065
FHB 135
15
10
5
0
0 50
100
150 200
250
FHB 320
Valves
Bypass valve pressure drop
0.90
0.60
0.30
0.00
0 40
80
120 160
200
0.90
0.60
0.30
0.00
0 20
40
60 80
100
FHB 050 - 065
0.90
0.60
0.30
0.00
0 75
150
225 300
375
FHB 135
FHB 320
266
15
10
5
0
0 18
36
54 72
90
15
10
5
0
0 12
24
36 48
60
FHB 050 - 065
FHB 135
15
10
5
0
0 50
100
150 200
250
FHB 320
Valves
Bypass valve pressure drop
0.90
0.60
0.30
0.00
0 40
80
120 160
200
0.90
0.60
0.30
0.00
0 20
40
60 80
100
FHB 050 - 065
0.90
0.60
0.30
0.00
0 75
150
225 300
375
FHB 135
FHB 320
266
15
10
5
0
0 18
36
54 72
90
15
10
5
0
0 12
24
36 48
60
FHB 050 - 065
FHB 135
15
10
5
0
0 50
100
150 200
250
FHB 320
Valves
Bypass valve pressure drop
Flow rate l/min
Flow rate l/min
Flow rate l/min
Flow rate l/min
Flow rate l/min
Flow rate l/min
∆p bar
∆p bar
∆p bar
∆p bar
∆p bar
∆p bar
Check Valve
Check Valve
Check Valve
High Pressure lters
564
FHB
High Pressure lters
565
Designation & Ordering code
COMPLETE FILTER
FHB FHB050
Valves
DTBS
-
-
-
-
Element ∆p
N
S
20 bar
210 bar
Series and size
Conguration example:
FHB050 A2 SF1T A06 P01
FHB050
Valves
Length
Seals
A
V
NBR
FPM
Connections
F1 Manifold
S
B
T
Without bypass
With bypass 6 bar
With check valve, without bypass
D With check valve, with bypass 6 bar
Execution
P01
Pxx
MP Filtri standard
Customized
Element series and size
HP050
Conguration example:
Execution
P01
Pxx
MP Filtri standard
Customized
HP050 A2 SA06 P01
Element ∆p
N
S
20 bar
210 bar
Element length
Seals
A
V
NBR
FPM
FILTER ELEMENT
1 2 3 4 5
1 2 3 4 5
Filtration rating (lter media)
Filtration rating (lter media)
A03
A03
A10
A10
A06
A06
Inorganic microber
Inorganic microber
3 µm
3 µm
Inorganic microber
Inorganic microber
10 µm
10 µm
Inorganic microber
Inorganic microber
6 µm
6 µm
M25
M25
A16
A16
A25
A25
Wire mesh
Wire mesh
25 µm
25 µm
Inorganic microber
Inorganic microber
16 µm
16 µm
Inorganic microber
Inorganic microber
25 µm
25 µm
CLOGGING INDICATORS
See page
T2 Plug (not included)
PLUGS
See page
723
743
DEA
DEU
DEM
DLA
DLEElectrical differential pressure indicator
Electrical differential pressure indicator
Electrical differential pressure indicator
Electrical / visual differential pressure indicator
Electrical / visual differential pressure indicator
DVA
DTA
DVM
Visual differential pressure indicator
Electronic differential pressure indicator
Visual differential pressure indicator
High Pressure lters
566
Dimensions
FHBFHB050
FHB050
Filter
length
H
[mm]
1
2
3
4
5
185
222
264
312
434
Ø68
Ø10.5
OUT
IN
Recommended
clearance space
for maintenance
Drain plug
only length 5
Nr. 2 holes
Connection for
diff. pressure indicator
T2 plug not included
High Pressure lters
567
Designation & Ordering code
COMPLETE FILTER
FHB FHB065 - FHB135 - FHB320
FILTER ELEMENT
Element series and size
Conguration example:
Execution
P01
Pxx
MP Filtri standard
Customized
HP320 A4 HA06 P01
Element ∆p
N
H
20 bar
210 bar
Seals
A
V
NBR
FPM
HP065 HP135 HP320
Element length
1
2
3
4
HP320HP135HP065
-
-
Series and size
Conguration example:
FHB320 A4 HF1S A06 P01
Valves
Seals
A
V
NBR
FPM
Connections
F1 Manifold
FHB065 FHB135 FHB320
Length
1
2
4
3
FHB320FHB135FHB065
-
-
S
B
T
Without bypass
With bypass 6 bar
With check valve, without bypass
D With check valve, with bypass 6 bar
Valves
DTBS
-
-
-
-
Element ∆p
N
H
20 bar
210 bar
Execution
P01
P02
Pxx
MP Filtri standard
Maintenance from the bottom of the housing
Customized
4321
-
-
-
Filtration rating (lter media)
Filtration rating (lter media)
A03
A03
A10
A10
A06
A06
Inorganic microber
Inorganic microber
3 µm
3 µm
Inorganic microber
Inorganic microber
10 µm
10 µm
Inorganic microber
Inorganic microber
6 µm
6 µm
M25
M25
A16
A16
A25
A25
Wire mesh
Wire mesh
25 µm
25 µm
Inorganic microber
Inorganic microber
16 µm
16 µm
Inorganic microber
Inorganic microber
25 µm
25 µm
CLOGGING INDICATORS
See page
T2 Plug (not included)
PLUGS
See page
723
743
DEA
DEU
DEM
DLA
DLEElectrical differential pressure indicator
Electrical differential pressure indicator
Electrical differential pressure indicator
Electrical / visual differential pressure indicator
Electrical / visual differential pressure indicator
DVA
DTA
DVM
Visual differential pressure indicator
Electronic differential pressure indicator
Visual differential pressure indicator
High Pressure lters
568
Dimensions
FHBFHB065 - FHB135 - FHB320
FHB065
Filter
length
H
[mm]
1
2
3
194
225
327
Ø68
Ø10.5
OUT
IN
Recommended
clearance space
for maintenance
Nr. 2 holes
Connection for
diff. pressure indicator
T2 plug not included
High Pressure lters
569
FHB
FHB135
Filter
length
H
[mm]
1
2
3
268
381
456
Ø77
FHB065 - FHB135 - FHB320
Dimensions
OUT
IN
Recommended
clearance space
for maintenance
Nr. 4 holes
Connection for
diff. pressure indicator
T2 plug not included
High Pressure lters
570
FHB
Ø133
FHB320
Length 1 - 2 - 3 Length 4
Filter
length
H
[mm]
H2 [mm]
Execution
P01 P02
1
2
3
4
301
424
556
709
150
150
150
150
-
-
-
550
FHB065 - FHB135 - FHB320
Dimensions
OUT
IN
Recommended
clearance space
for maintenance
Recommended
clearance space
for maintenance
Drain
plug
Nr. 4 holes
Connection for
diff. pressure indicator
T2 plug not included
High Pressure lters
571
Order number for spare parts
FHB SPARE PARTS
Item:
Filter
series
Seal Kit code numberFilter
element NBR FPM
See
order
table
2
Q.ty: 1 pc. Q.ty: 1 pc. Q.ty: 1 pc. Q.ty: 1 pc.Q.ty: 1 pc.
(3a ÷ 3n)
3 4 5 6
Indicator connection plug Bypass assembly Non-bypass assembly
NBR NBR NBRFPM FPM FPM
T2H T2V
02050412 02001312 0200131402050413 02001385 02001386
FHB 050
02050266
02050273
02001312
02001381
02001314
02001383
02050270 02001312 02001314
02050277
02050284
02001385
02001382
02001386
02001384
02050281 02001385 02001386
FHB 065
FHB 320
FHB 135
FHB 050 - 065 - 135 - 320
3n
3e
3d
3a
3b
3c
2
3h
3m
3h
3m
6
5
3g
3f
4
High Pressure  lters
572
HIGH PRESSURE FILTERS
Designation & Ordering code
CLOGGING INDICATORS
Series
Series
DE
T2
DL
DV
DT
Conguration example 1:
DE HM 50F12 P01
Conguration example
T2 H
Conguration example 3:
DL VE 71A20 P01
Conguration example 4:
DT HA 70F50 P01
Conguration example 5:
DV VM 70 P01
Type
A A
U
E
M M
Pressure setting
50
70
95
5.0 bar
7.0 bar
9.5 bar
Standard type With automatic reset
Electrical differential pressure indicator
Plug
Standard type 210 bar, UL certied
For high power supply
Electronic differential pressure indicator
With wired electrical connection With manual reset
Electrical/Visual differential pressure indicator
Visual differential pressure indicator
DIFFERENTIAL PRESSURE INDICATORS
PLUGS
Seals
H
V
HNBR
FPM
-
-
-
-
-
-
DLDE DT DV
Conguration example 2:
DE HU 50A50 P01 UL
Certications
Without
UL certication
OTHERSDEU
-
-
UL
DEMDEA DVADTADEU DVMDLA DLE
-
Seals
H
V
HNBR
FPM
-
DEA DVADTADEM DVMDLADEU DLE
DEA DEM
-
DLE DTDLADEU
--
-
Thermostat
A
F
Without thermostat
With thermostat
Electrical connections
20
10
30
50
52
35
51
70
71
DEA DEUDEM
-
- -
- -
- -
- -
-- -
-- -
-- -
-- -
DLE DTDLA
--
---
---
---
---
--
--
--
--
Connection Deutsch DT-04-2-P
Connection AMP Timer Junior
Connection AMP Superseal series 1.5
Connection Deutsch DT-04-3-P
Connection EN 175301-803
Connection EN 175301-803, transparent base with lamps 110 Vdc
Connection EN 175301-803, transparent base with lamps 24 Vdc
Connection IEC 61076-2-101 D (M12)
Connection IEC 61076-2-101 D (M12), black base with lamps 24 Vdc
Option
P01
Pxx
MP Filtri standard
Customized
Clogging Indicators
723