2 Technical data
Flange-mounted motor
DMVA 108 to 370
Date: 09/2015
Version: 1.1
ID No.: 11378482
11
2.7 Hydraulic fluids
2.7.1 General
The selection of the suitable hydraulic fluid is substantially influenced by the expected operating temperature
depending on the ambient temperature that is equivalent to the tank temperature.
Use the comparative oil values for the selection of the suitable hydraulic fluid. See chapter 2.7.5.
ATTENTION
Mixing various mineral oil press
ure fluids is prohibited!
2.7.2 Operating limits
Depending on the operating temperature, the appropriate oil must be selected taking into account the viscosity
c
haracteristics according to the following conditions:
- Cold start: max. approx. 1600 mm
2
/s *
- Normal operation: at or above approx. 500 mm
2
/s *
- Optimal range of application: 16-36 mm
2
/s *
- At max. leakage-oil temperature, the viscosity must not be below 8 mm
2
/s (short term,
meaning < 3 min., 7 mm
2
/s).
- The shear stability (KRL) has to be
observed for multigrade oils.
*) Open circuit: relative to reservoir temperature
Closed circuit: relative to circuit temperature
In addition to the viscosity characteristics, the Liebherr GSP specification ID No. 10465804 must be observed.
2.7.3 Filling quantity
The required filling quantity can be customized; v
alues upon request.
Note
The hydraulic unit must be filled with oil and bled prior to initialization.
This must be inspected during operation and after extended downtime, and must be repeated as
necessary!
2.7.4 Filtering
- To maintain the specified pu
rity class “21/17/14 according to ISO 4406” under all circumstances, it is
necessary to filter the hydraulic fluid.
- The hydraulic fluid is filtered by means of the device-specific use of oil filters in the hydraulic system.
- Cleaning and maintenance interva
ls of the oil filter and for the entire oil circuit depend on the device usage,
and are found in the device-specific operating manual.