K3VLS Series
Swash Plate Type Axial Piston Pump
1
. Applications / Product Usage 2
. Safety Precautions 3
. Handling Precautions 4
. Conversion Factors, Formula and Denition 8
K3VLS Series Swash Plate Type Axial Piston Pump
Specications, General Descriptions, and Features 10
1. Ordering Code
1-1. Pump Options 11
1-2. Regulator Options 12
2. Technical Information
2-1. Specications 14
2-2. Functional Description of Regulator
Load Sensing and Pressure Cut-off 16
Electric Inverse Proportional Pressure Control 17
w/o Any Additional Control, w/cover plate for torque Limit 18
Pressure Cut-off 20
Torque Limiter 21
Torque Limiter with Power Shift 23
Electric Displacement Control (Positive Control) 25
2-3. Functional Description of Pump 27
3. Dimensions
3-1. Installation Dimensions
K3VLS50 28
K3VLS65 37
K3VLS85 47
K3VLS105 54
K3VLS150 63
3-2. Installation of Auxiliary Pumps 69
K3VLS Series Inquiry Form 71
CONTENTS
2
K3VLS Series
. Applications / Product Usage
The following must be taken into consideration before use.
1. The operating condition of the products
shown in this catalog varies depending
upon each application. Therefore, the
product suitability must be judged by the
designer of the hydraulic system and/
or the person who nalizes the technical
specications of the machine after analysis
and testing. The product specication shall
be determined based on the latest catalog
and technical documents. The system
must be designed taking into account the
possibility of machine failure to ensure
that all safety, warning, and application
requirements are met.
2. For the proper use of the products,
descriptions given in the SAFETY
PRECAUTIONS must be observed.
3. The technical information in this catalog
represents typical characteristics and
performance of the products as of the
published date.
4. If the intended use of the products is
included in the following, please consult
with Kawasaki in advance.
(1) Use the product in the operating
conditions or environments other
than those described in the technical
documents.
(2) Use the product in the nuclear sector,
aviation sector, medical sector, and/or
food sector.
(3) Use the product in applications which
may cause substantial harm to others
and their property, and especially in
applications where ensuring safety is a
requirement.
5. The information described in this catalog
is subject to change without notice. For the
latest information, please contact Kawasaki.
3
. Safety Precautions
Before using the product, you MUST read this catalog and MUST fully understand how
to use the product. To use the product safely, you MUST carefully read all Warnings and
Cautions in this catalog.
1. Cautions related to operation
2. Warnings and cautions related to
installation and removal of the product
3. Warnings and cautions for operation
4. Cautions related to maintenance
- Use the personal protective equipment to
prevent injury when the product is in operation.
- Some components are heavy. Handle the
product carefully not to hurt your hands and
lower back.
- Do not step on, hit or drop , or apply strong
force to the product, as these actions may
cause operation failure, product damage, or oil
leakage.
- Wipe off any oil on the product or the oor
completely, as oil can create slippery conditions
that may cause drop of the product and
personal injury.
- Installation, removal, piping, and wiring must
be done by a qualied technician.
- Make sure that the hydraulic power unit
is turned off and that the electric motor or
engine has completely stopped before starting
installation or removal. You must also check
that the system pressure has dropped to zero.
- Make sure that the power source is turned off
before installing electric components to reduce
the risk of electric shock.
- Clean the threads and the mounting surface
to prevent damage or oil leakage. Inadequate
cleaning may cause insufcient torque and
broken seals.
- Use the designated bolts and fasten them with
prescribed torque when installing the product.
Use of undesignated bolts, and excessive or
insufcient tightening torque may induce
operation failure, damage, or oil leakage.
- Always equip the product with explosion or
ignition protection if it is used in potentially
explosive or combustible atmospheres.
- Shield rotary parts, such as the motor and
pump shaft, to avoid injury.
- Stop operation immediately, and take proper
measures when the abnormality such as
unusual noise, oil leakage, and smoke is found.
Continuing operation under such condition may
bring about damage, a re hazard, or injury.
- Make sure that all pipes, hoses, and
connecting points with pipes or hoses, are
correctly connected and tightened before
starting operation.
- Use the product under the operating
conditions and limitations described in the
catalog, drawings, and specication sheets.
- Do not touch the product in operation. to
reduce the risk of skin burn.
- Use the proper hydraulic oil and maintain the
ltration at the recommended level to prevent
premature wear and damage.
- Never modify the product without approval
from Kawasaki.
- Disassembly of the product may void the
warranty.
- Keep the product clean and dry when storing
or transporting.
- The seals may need to be replaced if the
product has been stored for an extended period
of time.
- Making adjustments of this product will result
in the warranty being null and void.
Viscosity [mm
2
/s(cSt)]
Fluid temperature
[
C ( F)]
Normal operating
range
Allowable range
10 to 200 10
to 1,000
20 to 95 ( 4 to 203)
1000
600
400
200
100
80
60
40
20
10
20 20 40 60 80 95
100
0
Normal operating range
kinematic viscosity (cSt)
allowable temperature range
uid temperature ( )
4
K3VLS Series
. Handling Precautions
1. Operating Fluid and
Temperature Range
1) Operating uid
Values shown in this catalog are based upon using
mineral oil based anti-wear hydraulic uid. To
ensure optimal performance use of mineral oil
based anti-wear hydraulic uid is recommended.
2) Viscosity and temperature range
To minimize both oil and seal deterioration, a
maximum operating temperature of 60
should
be considered. Please note that the regulator
may become slow to respond when operating
at low temperatures (below 20
) in extreme
cold environments. At such low temperature it
is strongly suggested that a warm up cycle is
introduced until an operating temperature of 20
is achieved.
2. Filtration and Contamination
Control
1) Filtration of working oil
The most important means to prevent premature
damage to the pump and associated equipment
and to extend its working life, is to ensure that
hydraulic uid contamination control of the system
is working effectively.
This begins by ensuring that at the time of
installation that all piping, tanks etc. are rigorously
cleaned in a sanitary way. Flushing should be
provided using an off line ltration system
and after ushing the lter elements should be
replaced.
A full ow return line lter of 10 micron nominal
should be utilised to prevent contaminant ingress
from the external environment, a 5 to 10 micron
lter with the tank's breather is also recommended.
2) Suggested acceptable contamination
level
The relationship between contamination level and
pump life is very difcult to predict as it depends
on the type and nature of the contaminant present
in the system. Sand or Silica in particular, due to
its abnrasive nature, does signicantly reduce the
expected life of a pump. Based on the precondition
that there is no signicant presence of Silica type
substances then a minimum Cleanliness level of
-/18/15 ISO 4406 or SAE AS 4059E Table 1 Class 9
(NAS 1638 Class 9).
5
3. Drive Shaft Coupling
Alignment between the prime mover and the pump shaft should be within 0.05 mm TIR*. In case the pump is
directly coupled to the engine ywheel, use a exible coupling.
*TIR = Total Indicator Reading
4. Oil Filling and Air Bleeding
1) Pump case lling
Be sure to ll the pump casing with oil through the drain port, lling only the suction line with oil is totally
in-sufcient. The pump contains bearings and high-speed sliding parts including pistons with shoes and a
spherical bush that need to be continuously lubricated. Part seizure or total premature failure will occur
very quickly if this procedure is not rIgidly followed.
2) Air bleeding
Run the pump unloaded for a period to ensure that all residual air within the system is released.
3) Long term out of usage
It is undesirable to leave the pump out of use for a long period e.g. a year or more. In such a situation it is
recommended that the pump is run for a short period on a more frequent basis even if it is just unloaded.
With regard to a pump held in storage then rotating the shaft on a frequent basis is sufcient. If the pump is
left out for more than the suggested time it will require a service inspection.
. Handling Precautions
dial gauge
(
reading a
)
dial gauge
(
reading b
)
datums
datums
D
b
a/2
0.025mm
SIN
-1
(b/D)
0.2
P dr
0.1sec
0.4MPa
peak
0.1MPa
normal
6
K3VLS Series
5. Drain Piping
1) Installation of drain line
It is the preferred option to mount the pump with the case drain piping initially rising above the pump
before continuing to the tank. Do not connect the drain line to the inlet line.
The uppermost drain port should be used and the drain piping must be larger in size than the drain port
to minimise pressure in the pump case. The pump case pressure must not exceed 0.1 MPa as shown in the
illustration below. (Peak pressure must never exceed 0.4 MPa.)
Cautions
A) Inlet and drain pipes must be immersed by
200 mm minimum from the lowest level under
operating conditions.
B) Height from the oil level to the centre of the
shaft must be within 1 meter maximum.
C) The oil in the pump case must be relled when
the pump has not been operated for one month
or longer.
. Handling Precautions
Fluid level
200mm
top of pump case.
minimum depth
Must be higher than
2) Size of drain hose or drain pipe
The internal bore size of the drain hose or drain pipe must be larger than that of the drain port. Arrange the
drain line as short as possible.
7
7. Shaft Loading and Bearing Life
Although K3VLS pumps are equipped with bearings that can accept some external thrust and radial forces,
application of such loads will affect bearing life. Depending on the load magnitude , the load position, and
the load orientation, bearing life may be signicantly reduced.
. Handling Precautions
within 1m
200mm
minimum depth
Fluid level
200mm
minimum depth
within
1m
6. Mounting the Pump Above the Tank
Suction line
Formula Note
Displacement
1 cm
3
= 0.061 in
3
Pressure 1 MPa = 145 psi
Flow
1 L/min = 0.264 gpm US gallon
Torque
1 Nm = 0.74 lb ft
Power
1 kW = 1.341 hp
Weight
1 kg = 2.205 lb
8
K3VLS Series
Conversion Factors
Formula
Denition
. Conversion Factors,
Formula and Denition
q = Pump displacement / rev. cm
3
(in
3
)
L = Input power kW (hp)
N = Speed min
-1
(rpm)
P = P
d
- P
s
MPa (psi)
P
d
= Pump delivery pressure MPa (psi)
P
s
= Pump suction pressure MPa (psi)
P
L
= Load sensing pressure MPa (psi)
P
dr
= Pump case pressure MPa (psi)
P
f
= Power shift pressure MPa (psi)
P
sv
= Servo pressure MPa (psi)
T = Input torque Nm (lbf-ft)
T
max
= Maximum input torque Nm (lbf-ft)
v
= Pump volumetric efciency
m
= Pump mechanical efciency
t
= Pump total efciency
Metric system Imperial system
Output ow Q = q x N x
v
/ 1000 L/min Q = q x N x
v
/ 231 gal/min
Input torque T = q x
P / 2 /
m
Nm T = q x P / 24 /
m
lbf ft
Input power L = T x N / 9550 = Q x
P / 60 /
t
kW L = T x N / 5252 = Q x P / 1714 /
t
hp
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
MEMO
9
10
K3VLS Series
Swash Plate Type Axial Piston Pump
K3VLS Series
General Descriptions
The K3VLS are variable displacement axial piston
pumps of swash plate design, suitable for use in
mobile applications and industrial vehicles with
medium pressure hydraulic systems.
The K3VLS pumps enable exible conguration in a
wide range of applications with their compact size
and light weight design.
The K3VLS series pumps are available in size (rated
displacement) ranging from 50 to 150 cm
3
/rev
with various control options, such as load sensing,
pressure cut-off, and horsepower controls.
Specications
Size : 50, 65, 85, 105, 150
Rated Pressure : 28 MPa
Peak Pressure : 35 MPa
Features
• Variable axial piston pump of swash plate design
in open circuits
• High overall efciency
• Compact size
• Light weight
• Excellent reliability
• Numerous control options
• High stability
• Highly responsive controls
1. K3VLS Series Pump
K
3VLS Series, Variable Displacement,
Axial Piston, Open Loop Pump
2
. Pump Size
50 65 85 105 150
M
aximum Displacement cm
3
5
. Through Drive and Porting
50 65 85 105 150
0 w/o Through Drive, Side Ported
A
SAE-A Through Drive, Side Ported
B
SAE-B Through Drive, Side Ported
BB SAE-BB Through Drive, Side Ported
C
SAE-C, 2/4 bolt, Through Drive, Side Ported
CC SAE-CC, 2/4 bolt, Through Drive, Side Ported
N
w/ Through Drive Shaft, w/o Coupling,
Closed w/ Steel Cover, Side Ported
R
w/o Through Drive, Rear Ported
7
. Mounting Flange and Shaft
50 65 85 105 150
B
SAE-B Mount & SAE B Spline
BB SAE-B Mount & SAE BB Spline
C
SAE-C Mount & SAE C Spline
(
Only SAE C-
4
mount for K
3
VLS
65
&
150
)
CC
SAE-C Mount & SAE CC Spline
(Only SAE C-4 mount for K3VLS150)
D
SAE-D Mount & SAE D Spline
(for K3VLS150, w/ Torque Limit Control is not available)
K
2
SAE-B Mount & SAE BB Keyed Shaft (for K3VLS50 & 65)
K
3
SAE-C Mount & SAE C Keyed Shaft (for K3VLS65 & 85)
K
4
SAE-C Mount & SAE CC Keyed Shaft (for K3VLS105)
8
. Flange / Mounting Fixing Thread (Suction-Delivery, Through Drive)
Flange Thread Suction- Delivery
Mounting Thread Through Drive
50 65 85 105 150
S
Unied Metric
H
Metric Metric
6
. Direction of Rotation
50 65 85 105 150
R
Clockwise
L
Counterclockwise
3
. O-ring Material
-
NBR (Orings:Nitrile rubber, Oil Seal: Fluoro rubber)
V
Viton (Orings: Fluoro rubber, Oil Seal: Fluoro rubber)
4
. Series Type Code
1 Standard Type
K3VLS 105 - 1 BB R CC S - L1 A A M1
Model Code
1235678910 12114
: Available
: Please contact Kawasaki
: Not available
:
Only available in Europe/US
11
1
Ordering Code
1-1 Pump Options
12
K3VLS Series
1. Ordering Code
1-2 Regulator Options
9
. Flow Control
Load Sense Pressure Cut-Off Control
50
65
85
105
150
L
0 w/ LS, w/ Bleed-off Orice w/ Pressure Cut-Off
L
1
w/ LS, w/o Bleed-off Orice w/ Pressure Cut-Off
P
0 w/o LS w/ Pressure Cut-Off
K3VLS 105 - 1 BB R CC S - L1 A A M1
- T***
10
. Differential Pressure Setting Range (For the details see page
14
)
50
65
85
105
150
Blank
In case PR
2
is chosen at "
9
"
A
Standard Setting Range (1.0 - 3.0MPa)
C
High Setting Range (1.5 - 4.0MPa)
Torque Limit Control
50
65
85
105
150
00
w/o Any Additional Control, w/ cover plate for Torque Limit
A
w/o Power Shift Control
B
w/ Power Shift Control Pilot Operated
w/ Electric Proportional Reducing Valve,
C
2 Voltage:24V, Deutsch Connector
C
3 Voltage:12V, Deutsch Connector
Electric Displacement Control (Positive Control) 50 65 85 105 150
w/ Fail-safe Function
E
2 Voltage:24V, Deutsch Connecter
E
3
Voltage:
12
V, Deutsch Connecter
w/o Fail-safe Function,
F
2 Voltage:24V, Deutsch Connecter
F
3 Voltage:12V, Deutsch Connecter
11
. Additional Control Options
(For the additional control options "
11
", only one option per column is acceptable.)
50
65
85
105
150
Blank
w/o Any Additional Control or in case PR
2
is chosen at "
9
"
Model Code
1235678910 12 13114
: Available
: Please contact Kawasaki
: Not available
: Only available in Europe/US
Electric Inverse Proportional Pressure Control 50 65 85 105 150
PR
2
PR
2
: w/o LS, w/ Pressure Cut-Off – Electric Inverse Proportional
Pressure Control (
24
V, Deutsch Connector)
K3VLS 105 - 1 BB R CC S - L1 A A M1
- T***
12
. Torque Limit Setting (Available only with the attachment of Torque Limiter)
50
65
85
105
150
Blank
w/o Any Torque Limit Setting
H
1
H Spring, Corner Torque
85
%
H
2 H Spring, Corner Torque 75%
H
3 H Spring, Corner Torque 65%
H
4 H Spring, Corner Torque 55%
M
1 M Spring, Corner Torque 70%
M
2 M Spring, Corner Torque 60%
M
3 M Spring, Corner Torque 50%
M
4 M Spring, Corner Torque 40%
M
5 M Spring, Corner Torque 30%
13
. Special Sufx
T*** Special Sufx
Model Code
1235678910 12 13114
: Available
: Please contact Kawasaki
: Not available
: Only available in Europe/US
Code H1 to H4: for torque limit control with power shift control (Additional Control Option Code [11]: "B", "C2", and "C3")
Code M
1 to M5: for torque limit control without power shift control (Additional Control Option Code [11]:"A")
13
1. Ordering Code
1-2 Regulator Options
14
K3VLS Series
2
Technical Information
2-1 Specications
Size 50 65 85 105 150
Displacement cm
3
50 65 85 105 150
Pressure
Rated MPa 28
Peak MPa 35
Allowable case pressure MPa 0.1 continuous / 0.4 peak
Speed
Self prime
1
min
–1
2,700 2,600 2,500 2,300 2,200
Maximum
2
min
–1
3,250 3,000 3,000 2,640 2,400
Case volume L 0.8 1.0 1.2 1.7 2.3
Temperature range
C 20 to 95
Viscosity range cSt 10 to 1,000
Maximum contamination level ISO 4406 -/18/15
Allowable through
drive torque
Nm
SAE A 123 123 123 123
SAE B 380 380 380 380 380
SAE BB 435 435 435 435 435
SAE C 435 435 558 435
SAE CC 702 899
SAE D
Mass kg 21 25 31 37 52
Moment of inertia kg m
2
2.89 10
3
5.30 10
3
6.77 10
3
9.85 10
3
1.82 10
2
Torsional stiffness Nm/rad 4.56 10
4
5.26 10
4
6.79 10
4
1.32 10
5
1.99 10
5
Coating Red synthetic resin primer
1 Self prime speed is the maximum operating speed under the self priming condition at maximum displacement. Steady state inlet
pressure should be greater or equal to 0 MPa gauge.
2 Maximum speed is the maximum operating speed that can run without damage to the pump under restriction of operating conditions.
Allowable maximum input torque
1. SAE spline shaft
SAE B SAE BB SAE C SAE CC SAE D
Spline specications
13T
16/32 DP
15T
16/32 DP
14T
12/24 DP
17T
12/24 DP
13T
8/16 DP
Allowable maximum
input torque (Nm)
200 315 630 1,060 1,490
Pump size
K3VLS50
K3VLS65
K3VLS50
K3VLS65
K3VLS65
K3VLS85
K3VLS105
K3VLS150
K3VLS105
K3VLS150
K3VLS150
(Note) Maximum pressure must be reduced to operate within the allowable maximum input torque as below when the torque limit
control is not used.
SAE B spline K3VLS50: 24 MPa K3VLS65: 18 MPa
SAE C spline K3VLS150: 25 MPa
For above options, if 28 MPa is needed, use the torque limit control.
(Note) Maximum pressure must be reduced to operate within allowable maximum input torque as
below when the torque limit control is not used.
SAE BB Key K3VLS65: 22 MPa
For above options, if 28 MPa is needed, use the torque limit control.(Power shift H1 & H2 not available)
15
2. SAE keyed shaft
SAE BB SAE C SAE CC
Keyed Width (mm) 6.35 7.94 9.53
Allowable maximum
input torque (Nm)
230 430 700
Pump size
K3VLS50
K3VLS65
K3VLS65
K3VLS85
K3VLS105
2. Technical Information
2-1 Specications
16
K3VLS Series
2-2 Functional Description of Regulator
Load Sensing and Pressure
Cut-off
(Ordering Code [9]: L0 / L1)
This regulator has function of ow and pressure
control (i.e. load sensing control and pressure cut-
off control.)
To control ow a variable orice is used. (A
variable orice is not included in the pump and
shall be prepared separately.) Pump displacement
is controlled to maintain the differential pressure
across the orice constant. The ow is controlled
to a required ow regardless of pump delivery
pressure. In addition, there is a pressure cut off
function incorporated into the control. The pressure
cut-off function overrides the ow control function.
L0 control: with a bleed off orice
L1 control: without a bleed off orice
Releasing the pressure at port PL results in standby
condition, which provides zero ow at unloading
condition. The unloading pressure is typically
0.1 to 0.2 MPa higher than differential pressure
setting.
Differential pressure setting
Standard setting at factory : 1.5
+0.3/-0.2 MPa
Load sensing differential pressure range can be selected
from two setting ranges.
unit: MPa
Code Adjustment range Adjustment sensitivity
A 1.0 to 3.0 1.3 / turn
C 1.5 to 4.0 2.5 / turn
Pressure cut-off setting
Standard setting at factory
28 0/-1.5 MPa
Pressure cut –off setting range is from 5 MPa to 28 MPa.
unit: MPa
Adjustment range Adjustment sensitivity
5.0 to 28.0 8.0 / turn
Hydraulic circuit
Flow, Pressure control curve
2. Technical Information
Discharge pressure
Flow
Dr
B
A
a
PL
Variable
orice
Spool
1
Spool 2
Spool 1: Differential spool
Spool
2: Cut-off spool
Plugged at L
1 control
17
2-2 Functional Description of Regulator
Electric Inverse Proportional
Pressure Control
-Voltage:24V, Deutsch Connecter
(Ordering Code [9]: PR2)
This regulator is Electro-hydraulic pressure
control type of regulator. A current is input from
the controller to the solenoid of the regulator,
and the pressure is controlled by the inverse
proportional solenoid valve. Since the regulator
tries maintaining the pressure which is set by the
valve, the pump discharge is controlled according
to the load of the actuator. Thus, the pump supplies
only the amount of hydraulic oil required by the
actuator. Even if the input current to the solenoid
becomes zero at the electric failure of the machine,
the pressure set will be maximum, and the pump
displacement will be also maximum, so it functions
as electric fail-safe.
The pressure of cut-off valve can be set between
28MPa and 10MPa. The control effective range of
the solenoid is decided by the cut-off valve setting.
(e.g. in case the cut-off setting is 20MPa, the
control range is 230mA - 500mA.)
2. Technical Information
Input current
Discharge pressure
Max. pressure setting Input current control range
28 MPa 120 - 500 mA
26 MPa 150 - 500 mA
24 MPa 180 - 500 mA
22 MPa 210 - 500 mA
20 MPa 230 - 500 mA
18 MPa 250 - 500 mA
16 MPa 275 - 500 mA
14 MPa 300 - 500 mA
12 MPa 325 - 500 mA
10 MPa 350 - 500 mA
Control effective range
Input current – Discharge pressure curve
Hydraulic circuit
a2
Dr
B
A
a
Recommended dither condition for the input current
Dither frequency: 200 Hz
Dither amplitude: 200 mA
p-p
PR2
Rated current [mA] 700
Coil resistance (at 20
) [ ] 26.2
Power consumption (at cold) [W] 22
Connector type
Ladd Distribution
DT04-2P
Water proof IP69K
18
K3VLS Series
Dr
B
A
a
PL
2-2 Functional Description of Regulator
w/o Any Additional Control,
w/cover plate for Torque Limit
(Ordering Code [11]: 00)
When the "00" option is selected in section 11 of
the model code the K3VLS pump is supplied as a
torque limit ready pump. The pump has a blanking
plate tted instead of the torque limiter. This offers
better exibility to congure the pump as required.
The pump as ordered will function as a load sense
or pressure compensated pump depending on your
selection of ow control in section 9 of the model
code. If the torque limit blanking cover is then
replaced with a torque limit regulator the pump
has the torque limit control functionality. Note that
the torque limit regulator would need to be set.
2. Technical Information
Hydraulic circuit
19
2-2 Functional Description of Regulator
w/o Any Additional Control,
w/cover plate for Torque Limit
(Ordering Code [11]: 00)
2. Technical Information
a B
K3VLS50 168 68
K3VLS65 180 74
K3VLS85 182 81
K3VLS105 200 81
K3VLS150 210 94
b
a
Discharge pressure
Flow
Relief valve for
remote pressure control
Dr
B
A
a
Pc
(Out of scope of supply)
20
K3VLS Series
2-2 Functional Description of Regulator
Pressure Cut-off
(Ordering Code [9]: P0)
This regulator has function of pressure control.
As discharge pressure rises to the cut-off setting,
the pump displacement is reduced to prevent the
discharge pressure from exceeding and keep the
set pressure. It is imperative that a safety relief
valve be installed in the system.
By connecting the Pc port to a remote pressure
control relief valve, variable pump pressure control
can be achieved.
The remote pressure control relief valve is to
be set to 1.5 MPa below to the required system
pressure.
The remote control relief valve is out of scope of
supply.
Differential pressure setting
Standard setting at factory : 1.5
+0.3/-0.2 MPa
Load sensing differential pressure range can be selected
from two setting ranges.
unit: MPa
Code Adjustment range Adjustment sensitivity
A 1.0 to 3.0 1.3 / turn
C 1.5 to 4.0 2.5 / turn
Pressure cut-off setting
Standard setting at factory
28 0/-1.5 MPa
Pressure cut –off setting range is from 5 MPa to 28 MPa.
unit: MPa
Adjustment range Adjustment sensitivity
5.0 to 28.0 8.0 / turn
Hydraulic circuit
Flow, Pressure control curve
2. Technical Information
Discharge pressure
Flow
Dr
B
A
a
PL
Torque limiter
21
2-2 Functional Description of Regulator
Torque Limiter
(Ordering Code [11]: A)
L0/L1 control functions as previously noted. In
response to a rise in delivery pressure the swash
plate angle is decreased, restricting the input
torque. This regulator prevents excessive load
against the prime mover.
The torque limiter is comprised of two springs that
oppose the spool force generated by the system
pressure. By turning the adjustment screws, the
appropriate input torque limit can be set.
Torque limiter control setting is shown in the
attached table, and the torque limiter can be
adjusted by the torque value of the table. Refer to
the instruction manual for adjustment.
Hydraulic circuit
Torque limiter control curve
2. Technical Information
Flow
Flow
Input torque
Discharge pressure (MPa)
Input torque
Torque setting
22
K3VLS Series
2-2 Functional Description of Regulator
Torque Limiter Settings
(Ordering Code [11]: A)
2. Technical Information
Pump control curve (sample)
Torque setting without power shift function
Ordering code [12]
Pump size
M1 M2 M3 M4 M5
K3VLS50 155 135 110 90 65
K3VLS65 200 175 145 115 85
K3VLS85 265 227 190 150 115
K3VLS105 330 281 235 190 140
K3VLS150 470 400 335 265
Unit Nm
Discharge pressure
Flow
B
Dr
A
a
Pf
PL
Dr
B
A
a
1
PL
a
2
Psv
23
2-2 Functional Description of Regulator
Torque limiter is available with variable torque
limit control. Torque limit setting can be varied by
the external pilot pressure supply (code
B ) or
the integrated electric proportional control valve
with the external servo pressure supply (code
C ).
Code
B and C enable to shift the power control
setting as shown in the following torque limiter
control characteristic curve.
See the table (page 19) for torque setting according
to the external pilot pressure or the input current
to the integrated proportional valve. Required
servo pressure to the solenoid is 3.5 to 4.5 MPa.
Torque Limiter with Power Shift
(
Ordering Code [11]: B, C2, C3
)
Torque limiter control curve
Hydraulic circuit, code CHydraulic circuit, code B
External pilot pressure (Pf) range: 0 to 4.0 MPa Required servo pressure (Psv): 3.5 to 4.5 MPa
2. Technical Information
Flow
Input torque
Flow
Discharge pressure
Input torque
Ordering code [11] Code : B
Code : C2, C3
Ordering code [12]
Pump size
Pf
(MPa)
Current (mA) Max. Input torque (Nm)
24V
C2
12V
C3
H1 H2 H3 H4
K3VLS50
0.00 0 220 200 170 150
0.75 290 570 190 170 145 125
2.00 490 970 165 140 120 100
3.30 690 1,370 135 115 95 80
K3VLS65
0.00 0 285 250 220 190
0.75 290 570 245 215 185 160
2.00 490 970 210 180 150 130
3.30 690 1,370 175 145 120 100
K3VLS85
0.00 0 375 330 290 245
0.75 290 570 325 285 245 205
2.00 490 970 280 240 200 165
3.30 690 1,370 230 195 160 125
K3VLS105
0.00 0 455 405 360 310
0.75 290 570 395 350 305 260
2.00 490 970 340 295 250 210
3.30 690 1,370 280 235 200 160
K3VLS150
0.00 0 655 585 510 440
0.75 290 570 570 500 435 370
2.00 490 970 475 410 355 295
3.30 690 1,370 385 330 275 225
24
K3VLS Series
2-2 Functional Description of Regulator
Torque Limiter and Power Shift Settings
(
Ordering Code[11] : B, C2, C3
)
2. Technical Information
Pump control curve with power shift
(sample)
Table. Torque Setting with power-shift function
Input torque in the above table is planned value and for reference.
Displacement ratio (%) = Displacement / Max. Displacement
Recommended dither condition for the input current
Dither frequency: 100 Hz
Dither amplitude: for C2 200 mA
p-p
for C3 400 mA
p-p
C2 C3
Rated current [mA] 750 1,500
Coil resistance [
] 20.8 4.7
Power consumption (at 100
) [W] 19
Connector type
Ladd Distribution
DT04-2P
Water proof IP6K6/IPX9K
Flow
Input CurrentI
1
I
2
25
2-2 Functional Description of Regulator
The electric displacement control enables the
pump displacement to be changed according to the
change of input current to the solenoid. The pump
displacement can be adjusted in proportion to the
input current between the input current of I
1
and I
2
(refer to control curve).
With fail-safe function, at loss of input current in
such case of brakage of electric wires, the pump
displacement becomes maximum automatically.
Even under this condition the load sensing and
pressure cut-off control can be operated.
The fail-safe function is designed only for usage in
short period for emergency. Necessary repair is to
be made in the soonest opportunity.
For the hydraulic circuit refer to page 26.
Electric Displacement Control (Positive Control)
- With Fail-safe Function (Ordering Code[11]: E2, E3)
- Without Fail-safe Function (Ordering Code[11]: F2, F3)
2. Technical Information
Unit: mA
Ordering code I
1
I
2
E2, F2 200 600
E3, F3 400 1,200
Recommended dither condition for the input current
Dither frequency: 150 Hz
Dither amplitude: for E2, F2 200 mA
p-p
for E3, F3 400 mA
p-p
E2, F2 E3, F3
Rated current [mA] 700 1,400
Coil resistance (at 20
) [ ] 22.6 5.7
Power consumption (at 20
) [W] 11.2 11.2
Connector type
Ladd Distribution
DT04-2P
Water proof IP67
Note for start up
Due to its structure, the electric displacement control
requires larger input current than I
2
at start up, then
normal proportional control can be achieved between I
1
and I
2
.
Minimum operating pressure
With fail-safe function, in order to ensure safety and
repeatability of control the minimum operating pressure
of 5 MPa is to be secured. This avoids switching the
pump to fail-safe mode unexpectedly.
Input current ramp time requirement
With fail-safe function (Ordering code: E2, E3), ramp time
of 200 msec or larger is to be secured.
Control curve
Note for pumps with fail-safe
PL
Spool
2
Spool 1
Spool 3
Plugged at
L
1 Control
Dr
B
A
a
Spool 1: Electric Flow Control Valve
Spool
2: Differential Spool
Spool
3: Cut-off Spool
Dr
B
A
a
PL
Spool
2
Spool 1
Spool 3
Spool 1: Electric Flow Control Valve
Spool
2: Differential Spool
Spool
3: Cut-off Spool
Plugged at
L
1 Control
26
K3VLS Series
2-2 Functional Description of Regulator
Electric Displacement Control (Positive Control)
- With Fail-safe Function (Ordering Code[11]: E2, E3)
- Without Fail-safe Function (Ordering Code[11]: F2, F3)
2. Technical Information
Hydraulic Circuit With Fail-safe Function Hydraulic Circuit Without Fail-safe Function
27
2-3 Functional Description of Pump
Change Pump Maximum Displacement Ordering Code None
2. Technical Information
Qmax. Stopper (for Standard type with Horsepower control)
Pump Size
Default - 5 cm³ - 10 cm³ - 15 cm³ - 20 cm³ - 25 cm³
K3VLS50 50 45 40 35
K3VLS65 65 60 55
K3VLS85 85 80 75 70
K3VLS105 105 100 95 90
K3VLS150 150 145 140 130 125
Unit cm³
Pump Maximum displacement can be changed to the below list by the replacement of the Qmax. stopper.
It can be applied to Standard type and with Horsepower control. Refer to the instruction manual for
replacement procedures.
A
PL(Pc)
Dr
Dr
See port details
B
See port details
Dr
B
a
A
PL(Pc)
B
A
(Dr)
(Dr)
(Dr)
a
SAE
BB 30 Involute Spline Shaft
SAE J
744-25-4 15T 16/32DP
157.5
123
35
116
177
52.4
0.2
26.2
0.2
25
73
172
73
2-14.3
15
116
163
181
214
35
69
.8
0.2
35.7
0.2
53
108
101.6 h7
0
-0.035
25.4
0
-0.127
33
38
9
.7
0
-0.5
46
100
38
35
8080
77 135
15986
48.5
73 73
7272
( 91)
69
Adjustment screw for cut-off pressure
Adjustment screw for differential pressure
28
K3VLS Series
3
Dimensions
3-1 Installation Dimensions
K3VLS50 with Cut-off/Load Sense Control, Side Port
(Clockwise Rotation)
Model Code K3VLS 50 – 1 0 R BB – L0 A
K3VLS 50 – 1 0 R BB – L1 A
K3VLS 50 – 1 0 R BB – P0 A
Involute spline according to ANSI B92.1a, 30
pressure angle, at root, side t.
Dimensions in mm.
A
PL(Pc)
Dr
See port details
B
See port details
Dr
B
a
A
PL(Pc)
B
A
(Dr)
(Dr)
Dr
Dr
a
SAE
BB 30 Involute Spline Shaft
SAE J
744-25-4 15T 16/32DP
157.5
123
35
116
177
52.4
0.2
26.2
0.2
25
73
172
73
2-14.3
15
116
163
181
214
35
69
.8
0.2
35.7
0.2
64
101.6 h7
0
-0.035
25.4
0
-0.127
33
38
9
.7
0
-0.5
46
38
35
8080
77 158
86
48.5
73 73
7272
( 91)
75.4
69
61
168.5
179
.5
29
3-1 Installation Dimensions
K3VLS50 with Torque Limit Control, Side Port
(Clockwise Rotation)
Model Code K3VLS 50 – 1 0 R BB – L0 A A
K3VLS 50 – 1 0 R BB – L1 A A
K3VLS 50 – 1 0 R BB – P0 A A
Dimensions in mm.
3. Dimensions
PL(Pc)
Pf
85.6168
9.7
0
-0.5
46
116
181
249
25.4
0
-0.127
101.6
h
7
0
-0.035
33
35
35.7
0
.
2
69.8
0.2
38
15
69
2-14.3
73 73
72
61
35
158
48.5
80
77
72
80
172
38
73 73
91
116
177
52.4
0.2
35
25
163
179.5
157.5
123
26.2
0.2
116.3
34.3
57.5
30
K3VLS Series
3-1 Installation Dimensions
K3VLS50 Torque Limit with Power Shift Control, Side Port
(Clockwise Rotation)
Model Code K3VLS 50 – 1 N R BB – L0 A B
K3VLS 50 – 1 N R BB – L1 A B
K3VLS 50 – 1 N R BB – P0 A B
3. Dimensions
Dimensions in mm.
73
172
72
2-14.3
25.4
0
-0.127
101.6 h7
0
-0.035
116
181
21446
9
.7
0
-0.5
15
35
.7
0.2
69.8
0.2
48.5
158
35
116
177
163
26
.2
0.2
52.4
91
7373
35
77
85
.
6
(153)
72
79
.979.9
35
100
53
33
38
38
73
25
87
(247.5)
123
147.5
69
PL
PL
0.2
31
3-1 Installation Dimensions
K3VLS50 Electric Displacement Control , Side Port
(Clockwise Rotation)
Model Code K3VLS 50 – 1 0 R BB – L0 A E or – L0 A F
K3VLS 50 – 1 0 R BB – L1 A E or – L1 A F
K3VLS 50 – 1 0 R BB – P0 A E or – P0 A F
3. Dimensions
Dimensions in mm.
Dr
(Dr)
PL(Pc)
(Dr)
B
a
A
A,B
a
See port detailsSee port details
15
116
163
188
35
53
108
101.6 h7
0
-0.035
25.4
0
-0.127
33
38
9
.7
0
-0.5
46
100
48.5
69
3544
77 135
15985
.6
26.2
0.2
35.7
0.2
38
52.4
0.2
25
69.8
0
.
2
86 70
A,B
Dr
B
a
A
PL(Pc)
(Dr)
a
See port detailsSee port details
15
116
163
188
35
64
101.6 h7
0
-0.035
25.4
0
-0.127
33
38
9
.7
0
-0.5
46
3544
77 158
168
.585.6
48.5
69
26
.2
0.2
35.7
0.2
38
52.4
0.2
25
69.8
0
.
2
86 70
32
K3VLS Series
K3VLS50 Rear Port (Clockwise Rotation)
Model Code K3VLS 50 – 1 R R BB – L0 A
K3VLS 50 – 1 R R BB – L1 A
K3VLS 50 – 1 R R BB – P0 A
K3VLS50 Torque Limit Control, Rear Port
(Clockwise Rotation)
Model Code K3VLS 50 – 1 R R BB – L0 A A
K3VLS 50 – 1 R R BB – L1 A A
K3VLS 50 – 1 R R BB – P0 A A
3-1 Installation Dimensions
Dimensions in mm.
3. Dimensions
146
25.4
0
-0.127
33
38
9
.7
0
-0.5
46
22.225
0
-0.127
28
33
41
SAE BB 30 Involute Spline Shaft
SAE J
744-25-4 15T 16/32 DP
SAE
B 30 Involute Spline Shaft
SAE J
744-22-4 13T 16/32 DP
33
K3VLS50 Mounting Flange and Shaft Options
3-1 Installation Dimensions
Dimensions in mm.
3. Dimensions
SAE BB Spline Shaft
Ordering Code ”7. Mounting Flange and Shaft”: BB
SAE BB Keyed Shaft
Ordering Code “7. Mounting Flange and Shaft”: K2
SAE B Spline Shaft
Ordering Code ”7. Mounting Flange and Shaft”: B
Involute spline according to ANSI B92.1a, 30 pressure angle, at root, side t.
25.4
0
-0.05
34
38
M8
6.35
+0.025
+0.005
SAE "BB" Straight Shaft
SAE J
744-25-1
28.1
46
0
-0.3
34
K3VLS Series
K3VLS50 Porting Details
Main SAE Flanged Ports
Des Port name Port size Flange threads
Tightening torque (Nm)
UNF Threaded Version ('S' in position 8 of model code)
A Delivery port SAE J518C std pressure (code 61) 1" 3/8-16UNC-2B-18 57
B Suction port SAE J518C std pressure (code 61) 1-1/2" 1/2-13UNC-2B-22 98
Metric Version ('H' in position 8 of model code
A Delivery port PORT ISO 6162-1: 2012 P25M M10-17 57
B Suction port PORT ISO 6162-1: 2012 P38M M12-20 98
Auxiliary Ports
Des Port name Port size
Tightening torque (Nm)
SAE Version
Dr Drain port 3/4-16UNF-2B-14.3 (ISO 11926-1: 1995) 98
PL Load sensing port 7/16-20UNF-2B-11.5 (ISO 11926-1: 1995) 12
Pc Pressure control port 7/16-20UNF-2B-11.5 (ISO 11926-1: 1995) 12
a Gauge port 9/16-18UNF-2B-12.7 (ISO 11926-1: 1995) 59
Psv Servo pressure port 7/16-20UNF-2B-11.5 (ISO 11926-1: 1995) 12
Pf
Power shift pressure port
7/16-20UNF-2B-11.5 (ISO 11926-1: 1995) 12
Dr
(Dr)
a
SAE
A 2 hole
SAE J
744-82-2
8
-M10 Depth 17
SAE A 30 Involute Spline
SAE J
744-16-4 9T 16/32DP
15
116
163
234
35
53
108
101.6 h7
0
-0.035
25.4
0
-0.127
33
38
9
.7
0
-0.5
46
100
82.55
+
0
.
035
0
8
16
36
106
45
45
Dr
(Dr)
a
SAE
B 2 hole
SAE J
744-101-2
6
-M12 Depth 18
SAE B 30 Involute Spline
SAE J
744-22-4 13T 16/32DP
15
116
163
261
35
53
108
101.6 h7
0
-0.035
25.4
0
-0.127
33
38
9
.7
0
-0.5
46
100
101.6
+0.035
0
11
17
59
146
45
45
35
3. Dimensions
K3VLS50 Through Drive Options
3-1 Installation Dimensions
Dimensions in mm.
Through Drive SAE A
Ordering Code "5. Through Drive and Porting": A
Through Drive SAE B
Ordering Code "5. Through Drive and Porting": B
Involute spline according to ANSI B92.1a, 30 pressure angle, at root, side t.
Dr
(Dr)
a
SAE
BB 2 hole
SAE J
744-101-2
6
-M12 Depth 18
SAE "BB" 30 Involute Spline
SAE J
744-25-4 15T 16/32DP
15
116
163
261
35
53
108
101.6 h7
0
-0.035
25.4
0
-0.127
33
38
9
.7
0
-0.5
46
100
101.6
+0.035
0
11
17
59
146
45
45
36
K3VLS Series
K3VLS50 Through Drive Options
3-1 Installation Dimensions
Dimensions in mm.
Through Drive SAE BB
Ordering Code "5. Through Drive and Porting": BB
3. Dimensions
Involute spline according to ANSI B92.1a, 30 pressure angle, at root, side t.
73 73
172
84
14.3
14
.3
84 68
112
131
178
201
239
35
111
42.9
0.2
77.8
0
.
2
50
131
192
26
.2
0.2
52.4
0.2
25
76 76
35
168.5
125
73
41
.
5
82 163
137
50.5
71
15
8484
25.4
0
-0.127
101.6 h7
0
-0.035
33
38
9
.7
0
-0.5
46
PL(Pc)
Dr
Dr
A
PL(Pc)
A
a
B
Dr
Dr
A
B
B
(Dr)
Dr
Adjustment screw for cut-off pressure
Adjustment screw for differential pressure
See port details
See port details
SAE
BB 30 Involute Spline Shaft
SAE J
744-25-4 15T 16/32 DP
37
3-1 Installation Dimensions
K3VLS65 with Cut-off / Load Sense Control, Side Port
(Clockwise Rotation)
Model Code K3VLS 65 – 1 0 R BB – L0 A
K3VLS 65 – 1 0 R BB – L1 A
K3VLS 65 – 1 0 R BB – P0 A
Dimensions in mm.
Involute spline according to ANSI B92.1a, 30 pressure angle, at root, side t.
3. Dimensions
PL(Pc)
PL(Pc)
6377.4
146
172
76
84
2-14.3
25.4
0
-0.127
101.6 h7
0
-0.035
33
38
131
201
23946
9
.7
0
-0.5
15
42
.9
0
.
2
77.8
0.2
50.5
160
191
168.5
125
35
131
192
178
26
.2
0.2
52.4
0.2
91
7676
41.5
73
81
.6 180
76
84 71
50
25
35
38
K3VLS Series
3-1 Installation Dimensions
K3VLS65 Torque Limit Control, Side Port
(Clockwise Rotation)
Model Code K3VLS 65 – 1 0 R BB – L0 A A
K3VLS 65 – 1 0 R BB – L1 A A
K3VLS 65 – 1 0 R BB – P0 A A
Dimensions in mm.
3. Dimensions
Pf
PL(Pc)
6371
146
172
76
2-14.3
25.4
0
-0.127
101.6 h7
0
-0.035
131
201
239
46
9
.7
0
-0.5
15
42
.9
0.2
77.8
0.2
50.5
160
191
168.5
125
35
131
192
178
26
.2
0.2
52.4
0.2
91
7676
41.5
73
81
.
6180
76
84 84
50
25
35
127
.8
40.9
33
38
59.5
PL(Pc)
39
3. Dimensions
3-1 Installation Dimensions
K3VLS65 Torque Limit with Power Shift Control, Side Port
(Clockwise Rotation)
Model Code K3VLS 65 – 1 0 R BB – L0 A B
K3VLS 65 – 1 0 R BB – L1 A B
K3VLS 65 – 1 0 R BB – P0 A B
Dimensions in mm.
84
71 76
7676
31.75
0
-0.127
68
112
131
178
201
239
35
111
42.9
0.2
77.8
0.2
50
131
192
26
.2
0.2
52.4
0.2
25
76 76
35
168.5
125
73
41.5
82 163
137
50.5
148
114
.5
84
114.5
4-
14.
5
127
0
-0.05
56
12
.7
0
-0.5
42.5
51
15
116
a
AB
Dr
Dr
A
B
B
Dr
(Dr)
PL(Pc)
Dr
Dr
A
SAE
C 30 Involute Spline Shaft
SAE J
744-32-4 14T 12/24 DP
See port details
Adjustment screw for cut-off pressure
Adjustment screw for differential pressure
See port details
PL(Pc)
40
K3VLS Series
3. Dimensions
3-1 Installation Dimensions
K3VLS65 with Cut-off Load Sense Control, Side Port
(Clockwise Rotation, SAE C-4 Mount Type)
Model Code K3VLS 65 – 1 0 R C – L0 A
K3VLS 65 – 1 0 R C – L1 A
K3VLS 65 – 1 0 R C – P0 A
Dimensions in mm.
Involute spline according to ANSI B92.1a, 30 pressure angle, at root, side t.
146
172
76
2-14.3
25.4
0
-0.127
101.6
h7
0
-0.035
131
201
23946
9
.7
0
-0.5
15
42
.9
0.2
77.8
0.2
50.5
160
35
131
192
178
26
.2
0.2
52.4
0.2
91
7676
41.5
73
81
.6
(158)
76
84 84
50
25
35
111
63
33
38
88
(262)
125
168.5
71
PL
PL
41
3. Dimensions
3-1 Installation Dimensions
K3VLS65 Electric Displacement Control , Side Port
(Clockwise Rotation)
Model Code K3VLS 65 – 1 0 R BB – L0 A E or – L0 A F
K3VLS 65 – 1 0 R BB – L1 A E or – L1 A F
K3VLS 65 – 1 0 R BB – P0 A E or – P0 A F
Dimensions in mm.
178
207
44
52
.4
0.2
26.2
0.2
77.8
0.2
4536
42
.9
0.2
73
79 75
50
25
See port details
See port details
PL(Pc)
131
207
35
50.576
84 71
36 45
42
.9
0.2
26.2
0.2
77.8
0.2
52.4
0.2
160
180
25
50
See port details
See port details
PL(Pc)
42
K3VLS Series
K3VLS65 Rear Port (Clockwise Rotation)
Model Code K3VLS 65 – 1 R R BB – L0 A
K3VLS 65 – 1 R R BB – L1 A
K3VLS 65 – 1 R R BB – P0 A
K3VLS65 Torque Limit Control, Rear Port
(Clockwise Rotation)
Model Code K3VLS 65 – 1 R R BB – L0 A A
K3VLS 65 – 1 R R BB – L1 A A
K3VLS 65 – 1 R R BB – P0 A A
3-1 Installation Dimensions
Dimensions in mm.
3. Dimensions
146
25.4
0
-0.127
33
38
9
.7
0
-0.5
46
22.225
0
-0.127
28
33
41
SAE BB 30 Involute Spline Shaft
SAE J
744-25-4 15T 16/32 DP
SAE
B 30 Involute Spline Shaft
SAE J
744-22-4 13T 16/32 DP
43
K3VLS65 Mounting Flange and Shaft Options
3-1 Installation Dimensions
Dimensions in mm.
3. Dimensions
SAE BB Spline Shaft
Ordering Code ”7. Mounting Flange and Shaft”: BB
SAE C Keyed Shaft
Ordering Code “7. Mounting Flange and Shaft”: K3
SAE B Spline Shaft
Ordering Code ”7. Mounting Flange and Shaft”: B
Involute spline according to ANSI B92.1a, 30 pressure angle, at root, side t.
44
51
M8
7.94
+0.025
+0.005
SAE "C" Straight Shaft
SAE J
744-32-1
31.75 h7
0
-0.025
35.2
56
0
-0.3
SAE BB Keyed Shaft
Ordering Code “7. Mounting Flange and Shaft”: K2
25.4
0
-0.05
34
38
M8
6.35
+0.025
+0.005
SAE "BB" Straight Shaft
SAE J
744-25-1
28.1
46
0
-0.3
44
K3VLS Series
K3VLS65 Porting Details
Main SAE Flanged Ports
Des Port name Port size Flange threads
Tightening torque (Nm)
UNF Threaded Version ('S' in position 8 of model code)
A Delivery port SAE J518C std pressure (code 61) 1" 3/8-16UNC-2B-18 57
B Suction port SAE J518C std pressure (code 61) 2" 1/2-13UNC-2B-22 98
Metric Version ('H' in position 8 of model code
A Delivery port PORT ISO 6162-1: 2012 P25M M10-17 57
B Suction port PORT ISO 6162-1: 2012 P51M M12-20 98
Auxiliary Ports
Des Port name Port size
Tightening torque (Nm)
SAE Version
Dr Drain port 3/4-16UNF-2B-14.3 (ISO 11926-1: 1995) 98
PL Load sensing port 7/16-20UNF-2B-11.5 (ISO 11926-1: 1995) 12
Pc Pressure control port 7/16-20UNF-2B-11.5 (ISO 11926-1: 1995) 12
a Gauge port 9/16-18UNF-2B-12.7 (ISO 11926-1: 1995) 59
Psv Servo pressure port 7/16-20UNF-2B-11.5 (ISO 11926-1: 1995) 12
Pf
Power shift pressure port
7/16-20UNF-2B-11.5 (ISO 11926-1: 1995) 12
6-M10 Depth 17
SAE "A" 2 hole
SAE J
744-82-2
SAE "A" 30 Involute Spline
SAE J
744-16-4 9T 16/32 DP
45
82.55
+0.035
0
8
37
253
16
106
8-M12 Depth 18
SAE "B" 2 hole
SAE J
744-101-2
SAE "B" 30 Involute Spline
SAE J
744-22-4 13T 16/32 DP
45
45
146
101.6
+0.035
0
11
280
17
64
45
3. Dimensions
K3VLS65 Through Drive Options
3-1 Installation Dimensions
Dimensions in mm.
Through Drive SAE A
Ordering Code "5. Through Drive and Porting": A
Through Drive SAE B
Ordering Code "5. Through Drive and Porting": B
Involute spline according to ANSI B92.1a, 30 pressure angle, at root, side t.
8-M12 Depth 18
SAE "BB" 2 hole
SAE J
744-101-2
SAE "BB" 30 Involute Spline
SAE J
744-25-4 15T 16/32 DP
45
45
146
101.6
+
0
.
035
0
11
64
280
17
(C-2)
(C-4)
(C-4)
SAE "C"
2/4 hole
SAE J
744-127-2/4
SAE "C" 30 Involute Spline
SAE J
744-32-4 14T 12/24 DP
4-M12 Depth 22.5
(C-4)
2-M16 Depth 22.5
(C-2)
114.5
114.5
181
127
+0.04
0
14
61
.5
286
17
46
K3VLS Series
K3VLS65 Through Drive Options
3-1 Installation Dimensions
Dimensions in mm.
Through Drive SAE BB
Ordering Code "5. Through Drive and Porting": BB
Through Drive SAE C
Ordering Code "5. Through Drive and Porting": C
3. Dimensions
Involute spline according to ANSI B92.1a, 30 pressure angle, at root, side t.
114.5
181
83
74 83
31.75
0
-0.127
75
122
138
192
224
271
55
112
50.8
0.2
88.9
0.2
138
215
31
.8
0.2
66.7
0.2
83 83
42
182.5
128
78
44
87 165.5
140
53.5
18
215
2
-
17
.
5
4
-
14
.5
32
127
0
-0.05
12.7
0
-0.5
56
56
42
.5
60
9191
PL(Pc)
Dr
Dr
A
a
A
B
Dr
Dr
A
B
B
Dr
(Dr)
116
Adjustment screw for cut-off pressure
Adjustment screw for differential pressure
PL(Pc)
See port details
SAE
C 30 Involute Spline Shaft
SAE J
744-32-4 14T 12/24 DP
See port details
47
3-1 Installation Dimensions
Dimensions in mm.
3. Dimensions
K3VLS85 with Cut-off / Load Sense Control, Side Port
(Clockwise Rotation)
Model Code K3VLS 85 – 1 0 R C – L0 A
K3VLS 85 – 1 0 R C – L1 A
K3VLS 85 – 1 0 R C – P0 A
Involute spline according to ANSI B92.1a, 30
pressure angle, at root, side t.
(**) With a through drive is 86 mm
31.75
0
-0.127
127
0
-0.05
42.5
56
138
224
271
56
12
.7
0
-0.5
18
50
.8
0.2
88.9
0.2
60
80.463
91
83
114
.5
4-
14
.5
181
2
-
17
.
5
53.5
163
193
.5
182.5
128
42
138
215
192
31
.8
0.2
66.7
0.2
32
116
8383
44
78
86
.6 182.5
83
91 74
215
45
PL(Pc)
PL(Pc)
48
K3VLS Series
3-1 Installation Dimensions
Dimensions in mm.
3. Dimensions
K3VLS85 Torque Limit Control, Side Port
(Clockwise Rotation)
Model Code K3VLS 85 – 1 0 R C – L0 A A
K3VLS 85 – 1 0 R C – L1 A A
K3VLS 85 – 1 0 R C – P0 A A
Pf
PL(Pc)
PL(Pc)
31.75
0
-
0
.
127
127
0
-0.05
138
224
27156
12
.7
0
-0.5
18
50
.8
0
.
2
88.9
0
.
2
60
74 63
83
114
.5
4
-14.
5
181
2
-
17
.
5
53.5
163
193
.5
182.5
128
42
138
215
192
31
.8
0.2
66.7
0.2
32
116
8383
44
78
86
.6 182.5
83
91 91
215
45
130
.2
47.7
42
.5
56
59.5
49
3-1 Installation Dimensions
Dimensions in mm.
3. Dimensions
K3VLS85 Torque Limit with Power Shift Control, Side Port
(Clockwise Rotation)
Model Code K3VLS 85 – 1 0 R C – L0 A B
K3VLS 85 – 1 0 R C – L1 A B
K3VLS 85 – 1 0 R C – P0 A B
See port details
See port details
PL(Pc)
138
232
45
53.583
91 74
50 45
50
.8
0.2
31.8
0.2
88.9
0.2
66.7
0.2
60
32
163
182
.5
192
232
48
31.8
0.2
78
50
.8
0.2
80
50 45
97
88.9
0.2
66.7
0.2
60
32
See port details
A
B
See port details
PL(Pc)
50
K3VLS Series
3-1 Installation Dimensions
Dimensions in mm.
3. Dimensions
K3VLS85 Rear Port (Clockwise Rotation)
Model Code K3VLS 85 – 1 R R C – L0 A
K3VLS 85 – 1 R R C – L1 A
K3VLS 85 – 1 R R C – P0 A
K3VLS85 Torque Limit Control, Rear Port
(Clockwise Rotation)
Model Code K3VLS 85 – 1 R R C – L0 A A
K3VLS 85 – 1 R R C – L1 A A
K3VLS 85 – 1 R R C – P0 A A
51
3-1 Installation Dimensions
3. Dimensions
K3VLS85 Porting Details
Main SAE Flanged Ports
Des Port name Port size Flange threads
Tightening torque (Nm)
UNF Threaded Version ('S' in position 8 of model code)
A Delivery port SAE J518C high pressure (code 62) 1-1/4" 1/2-13UNC-2B-22 98
B Suction port SAE J518C std pressure (code 61) 2-1/2" 1/2-13UNC-2B-22 98
Metric Version ('H' in position 8 of model code
A Delivery port PORT ISO 6162-2: 2012 P32M M12-23 98
B Suction port PORT ISO 6162-1: 2012 P64M M12-22 98
Auxiliary Ports
Des Port name Port size
Tightening torque (Nm)
SAE Version
Dr Drain port 3/4-16UNF-2B-14.3 (ISO 11926-1: 1995) 98
PL Load sensing port 7/16-20UNF-2B-11.5 (ISO 11926-1: 1995) 12
Pc Pressure control port 7/16-20UNF-2B-11.5 (ISO 11926-1: 1995) 12
a Gauge port 9/16-18UNF-2B-12.7 (ISO 11926-1: 1995) 59
Psv Servo pressure port 7/16-20UNF-2B-11.5 (ISO 11926-1: 1995) 12
Pf
Power shift pressure port
7/16-20UNF-2B-11.5 (ISO 11926-1: 1995) 12
44
51
M8
7.94
+0.025
+0.005
SAE "C" Straight Shaft
SAE J
744-32-1
31.75 h7
0
-0.025
35.2
42.5
56
SAE "C" Straight Shaft
SAE J
744-32-1
181
2
-
17
.
5
4
-14.
5
61
56
0
-0.3
31.75
0
-0.127
K3VLS85 Mounting Flange and Shaft Options
SAE C Spline Shaft
Ordering Code “7. Mounting Flange and Shaft”: C
SAE C Keyed Shaft
Ordering Code “7. Mounting Flange and Shaft”: K3
6-M10 Depth 17
SAE "A" 2 hole
SAE J
744-82-2
SAE "A" 30 Involute Spline
SAE J
744-16-4 9T 16/32 DP
106
45
82.55
+0.035
0
8
37
281
16
8-M12 Depth 18
SAE "B" 2 hole
SAE J744
-
101
-
2
SAE "B" 30 Involute Spline
SAE J744-22-4 13T 16/32 DP
45
45
146
101
.
6
+0.035
0
11
64
308
17
52
K3VLS Series
K3VLS85 Through Drive Options
3-1 Installation Dimensions
Dimensions in mm.
Through Drive SAE A
Ordering Code "5. Through Drive and Porting": A
Through Drive SAE B
Ordering Code "5. Through Drive and Porting": B
3. Dimensions
Involute spline according to ANSI B92.1a, 30 pressure angle, at root, side t.
8-M12 Depth 18
SAE "BB" 2 hole
SAE J
744-101-2
SAE "BB" 30 Involute Spline
SAE J
744-25-4 15T 16/32 DP
45
45
146
101.6
+0.035
0
11
64
308
17
(C-2)
(C-4)
(C-4)
4-M12 Depth 22.5
(C-4)
2-M16 Depth 22.5
(C-2)
SAE "C"
30 Involute Spline
SAE J
744-32-4 14T 12/24 DP
SAE "C"
2/4 hole
SAE J
744-127-2/4
114
.5
114.5
181
127
+0.04
0
14
61
.5
314
17
53
3-1 Installation Dimensions
Dimensions in mm.
K3VLS85 Through Drive Options
Through Drive SAE BB
Ordering Code "5. Through Drive and Porting": BB
Trough Drive SAE C
Ordering Code "5. Through Drive and Porting": C
3. Dimensions
Involute spline according to ANSI B92.1a, 30 pressure angle, at root, side t.
114.5
181
88
77 88
72
124
143
197
228
274
45
130
50.8
0.2
88.9
0.2
143
221
31
.8
0.2
66.7
0.2
88 93
42
187.5
137
85
46.5
94 183.5
149
56.5
18
215
2
-
17
.
5
4-14
.
5
127
0
-0.05
12.7
0
-0.5
32
64
9898
PL(Pc)
a
A
B
Dr
Dr
A
B
Dr
Dr
A
B
Dr
(Dr)
116
38.1
0
-0.127
62
48
54
Adjustment screw for cut-off pressure
Adjustment screw for differential pressure
See port details
See port details
SAE
CC 30 Involute Spline Shaft
SAE J
744-38-4 17T 12/24 DP
PL(Pc)
54
K3VLS Series
3-1 Installation Dimensions
Dimensions in mm.
3. Dimensions
Involute spline according to ANSI B92.1a, 30 pressure angle, at root, side t.
K3VLS105 with Cut-off / Load sense Control, Side Port
(Clockwise Rotation)
Model Code K3VLS 105 – 1 0 R CC – L0 A
K3VLS 105 – 1 0 R CC – L1 A
K3VLS 105 – 1 0 R CC – P0 A
94
88
114
.5
215
2-17.5
4-
14
.
5
80.265.5
181
38.1
0
-
0
.
127
127
0
-0.05
143
228
27462
12
.7
0
-0.5
18
45
48
54
50
.8
0.2
88.9
0.2
64
56.588
94 77
17285
46.5
90 200
9388
116
211
.1
137
42
143
221
198
31
.8
0.2
66.7
0.2
32
187.5
PL(Pc)
PL(Pc)
55
3-1 Installation Dimensions
Dimensions in mm.
3. Dimensions
K3VLS105 Torque Limit Control, Side Port
(Clockwise Rotation)
Model Code K3VLS 105 – 1 0 R CC – L0 A A
K3VLS 105 – 1 0 R CC – L1 A A
K3VLS 105 – 1 0 R CC – P0 A A
Pf
PL(Pc)
PL(Pc)
88
114
.5
215
2-17.5
4-14
.5
77 65.5
181
38.1
0
-0.127
127
0
-0.05
143
27462
12
.7
0
-0.5
18
45
48
54
56
.588
98 98
172
200
116
211
.1
137
42
143
221
197
187
.5
88.9
0.2
85
148
47.7
62
64
50.8
0.2
31.8
0.2
66.7
0.2
46.5
32
56
K3VLS Series
3-1 Installation Dimensions
Dimensions in mm.
3. Dimensions
K3VLS105 Torque Limit with Power Shift Control, Side Port
(Clockwise Rotation)
Model Code K3VLS 105 – 1 0 R CC – L0 A B
K3VLS 105 – 1 0 R CC – L1 A B
K3VLS 105 – 1 0 R CC – P0 A B
See port details
See port details
PL(Pc)
143
237
45
56.588
94 77
172
84
200
50 45
50
.8
0.2
31.8
0.2
89
66.7
0.2
88.9
0.2
32
64
See port details
A
B
See port details
197
237
48
66
.7
0.2
32
88.9
0.2
64
50.8
0.2
31.8
0.2
4550
84
8697
PL(Pc)
57
3-1 Installation Dimensions
Dimensions in mm.
3. Dimensions
K3VLS105 Rear Port (Clockwise Rotation)
Model Code K3VLS 105 – 1 R R CC – L0 A
K3VLS 105 – 1 R R CC – L1 A
K3VLS 105 – 1 R R CC – P0 A
K3VLS105 Torque Limit Control, Rear Port
(Clockwise Rotation)
Model Code K3VLS 105 – 1 R R CC – L0 A A
K3VLS 105 – 1 R R CC – L1 A A
K3VLS 105 – 1 R R CC – P0 A A
58
K3VLS Series
3-1 Installation Dimensions
3. Dimensions
38.1
0
-0.127
62
181
2
-
17
.
5
4-
14
.
5
48
54
Ø31.75
0
-0.127
56
42
.5
48
SAE CC 30 Involute Spline Shaft
SAE J
744-38-4 17T 12/24 DP
SAE
C 30 Involute Spline Shaft
SAE J
744-32-4 14T 12/24 DP
K3VLS105 Mounting Flange and Shaft Options
Dimensions in mm.
Involute spline according to ANSI B92.1a, 30 pressure angle, at root, side t.
SAE CC Spline Shaft
Ordering Code "7.Mounting Flange and Shaft": CC
SAE CC Keyed Shaft
Ordering Code “7. Mounting Flange and Shaft”: K4
SAE C Spline Shaft
Ordering Code "7.Mounting Flange and Shaft": C
50
54
7/16-14UNC-2B
9.53
+0.030
+0.015
SAE "CC" Straight Shaft
SAE J
744-38-1
38.1
0
-0.025
42.92
62
0
-0.3
59
3-1 Installation Dimensions
3. Dimensions
K3VLS105 Porting Details
Main SAE Flanged Ports
Des Port name Port size Flange threads
Tightening torque (Nm)
UNF Threaded Version ('S' in position 8 of model code)
A Delivery port SAE J518C high pressure (code 62) 1-1/4" 1/2-13UNC-2B-22 98
B Suction port SAE J518C std pressure (code 61) 2-1/2" 1/2-13UNC-2B-22 98
Metric Version ('H' in position 8 of model code
A Delivery port PORT ISO 6162-2: 2012 P32M M12-23 98
B Suction port PORT ISO 6162-1: 2012 P64M M12-22 98
Auxiliary Ports
Des Port name Port size
Tightening torque (Nm)
SAE Version
Dr Drain port 1-1/16-12UN-2B-19 (ISO 11926-1: 1995) 167
PL Load sensing port 7/16-20UNF-2B-11.5 (ISO 11926-1: 1995) 12
Pc Pressure control port 7/16-20UNF-2B-11.5 (ISO 11926-1: 1995) 12
a Gauge port 9/16-18UNF-2B-12.7 (ISO 11926-1: 1995) 59
Psv Servo pressure port 7/16-20UNF-2B-11.5 (ISO 11926-1: 1995) 12
Pf
Power shift pressure port
7/16-20UNF-2B-11.5 (ISO 11926-1: 1995) 12
SAE "A"
2
hole
SAE J
744-82-2
6
-M10 Depth 17
SAE "A" 30 Involute Spline
SAE J
744-16-4 9T 16/32 DP
82.55
+0.035
0
8
37
286
106
45
16
SAE "B" 2 hole
SAE J
744-101-2
8
-M12 Depth 18
SAE "B" 30 Involute Spline
SAE J
744-22-4 13T 16/32 DP
101.6
+0.035
0
11
64
313
45
45
146
17
60
K3VLS Series
K3VLS105 Through Drive Options
3-1 Installation Dimensions
Dimensions in mm.
Through Drive SAE A
Ordering Code "5. Through Drive and Porting": A
Through Drive SAE B
Ordering Code "5. Through Drive and Porting": B
3. Dimensions
Involute spline according to ANSI B92.1a, 30 pressure angle, at root, side t.
(C-2)
(C-4)
(C-4)
4
-M
12
Depth
22
.
5
(C-4)
2-M16 Depth 22.5
(C-2)
SAE "C"
30 Involute Spline
SAE J
744-32-4 14T 12/24 DP
SAE "C"
2
/
4
hole
SAE J
744
-
127
-
2
/
4
127
+0.04
0
14
61
.5
319
114
.5
114.5
181
17
SAE "BB" 2 hole
SAE J
744-101-2
SAE "BB" 30 Involute Spline
SAE J
744-25-4 15T 16/32 DP
8-M12 Depth 18
101.6
+0.035
0
11
64
313
45
45
146
17
61
K3VLS105 Through Drive Options
3-1 Installation Dimensions
Dimensions in mm.
Through Drive SAE C
Ordering Code "5. Through Drive and Porting": C
3. Dimensions
Involute spline according to ANSI B92.1a, 30 pressure angle, at root, side t.
Through Drive SAE BB
Ordering Code "5. Through Drive and Porting": BB
(C-2)
(C-4)
(C-4)
4-M12 Depth 22.5
(C-4)
2-M16 Depth 22.5
(C-2)
SAE "CC"
2/4 hole
SAE J
744-127-2/4
SAE "CC" 30 Involute Spline
SAE J
744-38-4 17T 12/24 DP
127
+0.04
0
14
61
.5
319
114
.5
114.5
181
17
62
K3VLS Series
K3VLS105 Through Drive Options
3-1 Installation Dimensions
Dimensions in mm.
Through Drive SAE CC
Ordering Code "5. Through Drive and Porting": CC
3. Dimensions
Involute spline according to ANSI B92.1a, 30 pressure angle, at root, side t.
SAE D 30 Involute Spline Shaft
SAE J
744-44-4 13T 8/16 DP
191.542
166
255
31
.8
0.2
66.7
0.2
231
32
58
78
.
5
146
158
98
103
200
161.6
81
.7
200
4-20
211
44.45
0
-0.127
12.7
0
-0.5
23
166
255
301
45
50.8
0.2
88.9
0.2
137
64
98
104
46
.5
95
80
147
98
97 97
152.4
0
-0.05
60
67
PL(Pc)
PL(Pc)
Adjustment screw for cut-off pressure
Adjustment screw for differential pressure
A
B
See port details
See port details
63
3. Dimensions
Involute spline according to ANSI B92.1a, 30 pressure angle, at root, side t.
3-1 Installation Dimensions
Dimensions in mm.
K3VLS150 with Cut-off/Load Sense Control, Side Port
(Clockwise Rotation)
Model Code K3VLS 150 – 1 0 R D – L0 A
K3VLS 150 – 1 0 R D – L1 A
K3VLS 150 – 1 0 R D – P0 A
4- 14.5
SAE CC 30 Involute Spline Shaft
SAE J
744-38-4 17T 12/24 DP
114.5
114.5
81.7
152
191.5
42
205
285
31
.8
0.2
66.7
0.2
240.5
261
32
127
0
-0.05
12.7
0
-0.5
23
285
331
48
50.8
0.2
88
.
9
0.2
137
205
64
58
78
.5
146
158
98
98
104
103
46.5
200
114
104
98
110
97 97
Through
PL(Pc)
PL(Pc)
64
K3VLS Series
Involute spline according to ANSI B92.1a, 30 pressure angle, at root, side t.
3-1 Installation Dimensions
Dimensions in mm.
3. Dimensions
K3VLS150 with Cut-off/Load Sense Control, Side Port
(Clockwise Rotation, SAE C-4 Mount Type)
Model Code K3VLS 150 – 1 0 R CC – L0 A
K3VLS 150 – 1 0 R CC – L1 A
K3VLS 150 – 1 0 R CC – P0 A
See port details
See port details
PL(Pc)
205
300
48
114
98
88
.9
0
.
2
31.8
0.2
57 51
50
.8
0.2
66.7
0.2
106.6
100
32
46.5
98
108
.3
64
PL(Pc)
166
270
31
.8
0.2
57 51
50
.8
0.2
46.5
98
66
.7
0.2
106.6
100
88
.9
0.2
32
64
45
98
108
.3
See port details
See port details
65
3. Dimensions
3-1 Installation Dimensions
Dimensions in mm.
K3VLS150 Rear Port
(Clockwise Rotation, SAE C-4 Mount Type)
Model Code K3VLS 150 – 1 R R C – L0 A
K3VLS 150 – 1 R R C – L1 A
K3VLS 150 – 1 R R C – P0 A
K3VLS150 Rear Port
(Clockwise Rotation, SAE D Mount Type)
Model Code K3VLS 150 – 1 R R D – L0 A
K3VLS 150 – 1 R R D – L1 A
K3VLS 150 – 1 R R D – P0 A
Through
38.1
0
-0.127
62
48
54
31.75
0
-0.127
56
42
.5
48
114
.5
114.5
4- 14.5
SAE "CC" 30 Involute Spline Shaft
SAE J
744-38-4 17T 12/24 DP
SAE "C"
30 Involute Spline Shaft
SAE J
744-32-4 14T 12/24 DP
66
K3VLS Series
3-1 Installation Dimensions
3. Dimensions
K3VLS150 Mounting Flange and Shaft Options
Dimensions in mm.
Involute spline according to ANSI B92.1a, 30 pressure angle, at root, side t.
SAE CC Spline Shaft
Ordering Code "7. Mounting Flange and Shaft": CC
SAE C Spline Shaft
Ordering Code "7. Mounting Flange and Shaft": C
K3VLS150 Porting Details
Main SAE Flanged Ports
Des Port name Port size Flange threads
Tightening torque (Nm)
UNF Threaded Version ('S' in position 8 of model code)
A Delivery port SAE J518C high pressure (code 62) 1-1/4" 1/2-13UNC-2B-22 98
B Suction port SAE J518C std pressure (code 61) 2-1/2" 1/2-13UNC-2B-22 98
Metric Version ('H' in position 8 of model code
A Delivery port PORT ISO 6162-2:2012 P32M M12-23 98
B Suction port PORT ISO 6162-1:2012 P64M M12-23 98
Auxiliary Ports
Des Port name Port size
Tightening torque (Nm)
SAE Version
Dr Drain port 1-1/16-12UN-2B-19 (ISO 11926-1: 1995) 167
PL Load sensing port 7/16-20UNF-2B-11.5 (ISO 11926-1: 1995) 12
Pc Pressure control port 7/16-20UNF-2B-11.5 (ISO 11926-1: 1995) 12
a Gauge port 9/16-18UNF-2B-12.7 (ISO 11926-1: 1995) 59
Psv Servo pressure port 7/16-20UNF-2B-11.5 (ISO 11926-1:1995) 12
Pf
Power shift pressure port
7/16-20UNF-2B-11.5 (ISO 11926-1:1995) 12
347.5
101.6
+0.035
0
46.5
11
11
.5
317
.5
101
.
6
+
0
.
035
0
46.5
11
11
.5
146
45
45
SAE "B" 30 Involute Spline
SAE J
744-22-4 13T 16/32 DP
SAE "B"
2 hole
SAE J
744
-
101
-
2
SAE "B" 30 Involute Spline
SAE J
744-22-4 13T 16/32 DP
6-M12 Depth 18
SAE "B" 2 hole
SAE J
744
-
101
-
2
347.5
101.6
+0.035
0
46.5
11
11
.5
317
.5
101.6
+0.035
0
46.5
11
11
.5
146
45
45
SAE "BB" 30 Involute Spline
SAE J
744-25-4 15T 16/32 DP
SAE "BB"
30 Involute Spline
SAE J
744-25-4 15T 16/32 DP
6-M12 Depth 18
SAE "BB" 2 hole
SAE J
744-101-2
SAE "BB" 2 hole
SAE J
744-101-2
67
3. Dimensions
K3VLS150 Through Drive Options
3-1 Installation Dimensions
Dimensions in mm.
Through Drive SAE B
Ordering Code "5. Through Drive and Porting": B
Through Drive SAE BB
Ordering Code "5. Through Drive and Porting": BB
Involute spline according to ANSI B92.1a, 30 pressure angle, at root, side t.
374.5
127
+0.04
0
73.5
14
15
.5
344
.5
73
.5
14
15
.5
114.5(C-4)
114.5(C-4)
127
+
0
.
04
0
181(C-2)
SAE "C" 30 Involute Spline
SAE J
744-32-4 14T 12/24 DP
SAE "C"
2/4 holes
SAE J
744-127-2/4
4
-M
12
Depth
27
SAE "C" 2/4 holes
SAE J
744-127-2/4
2
-M16 Depth 27
(C-4)
(C-
2)
SAE "C"
30 Involute Spline
SAE J
744-32-4 14T 12/24 DP
374.5
127
+0.04
0
73.5
14
15
.5
344
.5
73
.5
14
15
.5
114.5(C-4)
114.5(C-4)
127
+0.04
0
181(C-2)
SAE "CC" 30 Involute Spline
SAE J
744-38-4 17T 12/24 DP
SAE "CC"
2/4 holes
SAE J
744-127-2/4
4
-M12 Depth 27
SAE "CC" 2/4 holes
SAE J
744-127-2/4
2
-M16 Depth 27
(C-4)
(C-
2)
SAE "CC"
30 Involute Spline
SAE J
744-38-4 17T 12/24 DP
68
K3VLS Series
K3VLS150 Through Drive Options
3-1 Installation Dimensions
Dimensions in mm.
Through Drive SAE C
Ordering Code "5. Through Drive and Porting": C
Through Drive SAE CC
Ordering Code "5. Through Drive and Porting": CC
3. Dimensions
Involute spline according to ANSI B92.1a, 30 pressure angle, at root, side t.
L1
L
m
1 m2
L2
69
3. Dimensions
Allowable mass moment for combination pump
K3VLS series can consist of multiple pumps using through
drive mounting. The second pump can be attached up to
the same size of the rst pump. The table below shows
the maximum allowable mass moment to the mounting
ange of the rst pump under the dynamic acceleration
of 10G. The moment can be calculated by the formula
shown below.
K3VLS50 K3VLS65 K3VLS85 K3VLS105 K3VLS150
SAE B
mount
SAE B
mount
SAE C
mount
SAE C-2
mount
SAE C-4
mount
SAE C-2
mount
SAE C-4
mount
SAE C
mount
SAE D
mount
Allowable mass
moment Tm (Nm)
(dynamic
acceleration
of 10G)
180 210 330 280 410 280 410 500 680
Calculation formula for mass moment
Tm = (m1
L1 + m2 L2 + m3 L3 + ) 1 / 102
m1, m2, m3
: Weight of pump [kg]
L1, L2, L3
: Center of gravity [mm]
See next page for values.
3-2 Installation of Auxiliary Pumps
70
K3VLS Series
Values for calculation of mass moment
Through drive
size ported
Length, weight 50
65
SAE B
mount
65
SAE C
mount
85 105
150
SAE C
mount
150
SAE D
mount
Without through
drive,
side ported
Total length L (mm) 214 239 239 271 274 331 301
Center of gravity L1
(from mounting face: mm)
107 117 113 126 131 166 139
Weight
(kg)
with torque limiter 24 28 29 34 40 57 55
without torque limiter 21 25 26 31 37 54 52
Without through
drive,
rear ported
Total length L (mm) 188 207 207 232 237 300 270
Center of gravity L1
(from mounting face: mm)
101 111 108 120 123 161 134
Weight
(kg)
with torque limiter 23 27 28 33 39 56 54
without torque limiter 20 24 25 29 35 53 51
SAE A
Total length L (mm) 234 253 253 281 286
Center of gravity L1
(from mounting face: mm)
116 129 126 136 137
Weight
(kg)
with torque limiter 26 31 32 37 42
without torque limiter 23 28 29 33 39
SAE B
SAE BB
Total length L (mm) 261 280 280 308 313 348 318
Center of gravity L1
(from mounting face: mm)
133 146 142 152 152 182 155
Weight
(kg)
with torque limiter 29 35 35 41 46 63 61
without torque limiter 26 31 32 37 43 60 58
SAE C
SAE CC
Total length L (mm)
278 314 319 375 345
Center of gravity L1
(from mounting face: mm)
150 157 156 198 171
Weight
(kg)
with torque limiter
37 42 47 69 67
without torque limiter
35 38 44 66 64
3. Dimensions
3-2 Installation of Auxiliary Pumps
71
K3VLS Inquiry Form
Please go to the page below link. An Inquiry Form which is formed by excel is available at the download section.
https://global.kawasaki.com/en/industrial_equipment/hydraulic/pumps/k3vls.html
72
K3VLS Series
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
K3VLS Series
MEMO
Kawasaki Precision Machinery (UK) Ltd.
Ernesettle Lane, Ernesettle, Plymouth, Devon, PL5 2SA United Kingdom
Phone +44-1752-364394 Fax. +44-1752-364816
http://www.kpm-eu.com
Kawasaki Precision Machinery (U.S.A.), Inc.
3838 Broadmoor Avenue S.E. Grand Rapids, Michigan 49512, U.S.A.
Phone +1-616-975-3100 Fax. +1-616-975-3103
http://www.kpm-usa.com
Kawasaki Precision Machinery (Suzhou) Ltd.
668 JianLin Rd, New District, Suzhou, 215151 China
Phone +86-512-6616-0365 Fax. +86-512-6616-0366
Kawasaki Precision Machinery Trading (Shanghai) Co., Ltd.
17th Floor (Room 1701), The Headquarters Building, No168, XiZang Road (M), Huangpu
District, Shanghai, 200001, China
Phone +86-21-3366-3800 Fax. +86-21-3366-3808
Kawasaki Chunhui Precision Machinery (Zhejiang) Ltd.
No.200 Yasha Road Shangyu Economic Development Zone, Shansyu, Zhejiang, 312300,
China
Phone +86-575-8215-6999 Fax. +86-575-8215-8699
Flutek, Ltd.
98 GIL 6, Gongdan-Ro, Seongsan-Ku, Changwon-Si, Kyungnam, 51567, Korea
Phone +82-55-210-5900 Fax. +82-55-286-5557
Wipro Kawasaki Precision Machinery Private Limited
No. 15, Sy. No. 35 & 37, Kumbalgodu Industrial Area, Kumbalgodu Village, Kengeri Hobli,
Bangalore, – 560074 ,India
Tokyo Head Ofce
1-14-5 Kaigan, Minato-ku, Tokyo 105-8315, Japan
Phone +81-3-3435-6862 Fax. +81-3-3435-2023
Kobe Head Ofce
Kobe Crystal Tower, 1-3 Higashikawasaki-cho 1-chome, Chuo-ku, Kobe 650-8680,
Japan
Phone +81-78-360-8607 Fax. +81-78-360-8609
Nishi-kobe Works
234, Matsumoto, Hasetani-cho, Nishi-ku, Kobe 651-2239, Japan
Phone +81-78-991-1160 Fax. +81-78-991-3186
Precision Machinery Business Division
OVERSEAS SUBSIDIARIES
http://www.khi.co.jp/kpm/
Cat. No. KPM2203 Feb. '22
M
Printed in Japan
Materials and specications are subject to change without manufacturer's obligation.
QR code
Precision Machinery
Business Division