Directional Valve Size 10 Installation dimensions ISO 4401 / DIN 24340 A10
KRACHT GmbH · Gewerbestr. 20 · 58791 Werdohl, Germany · Phone +49(0)23 92/935-0 · Fax +49 (0) 23 92 /935 209 · www.kracht-hydraulik.de · info@kracht-hydraulik.de
2
Nominal size 10
Maximum flow see p-Q characteristics
Max. operating pressure
at ports P, A, B 5076 psi (350 bar)
Max. operating pressure
at port T 3045 psi (210 bar)
Pressure losses see ∆p-Q characteristics
Hydraulic fluid Hydraulic oils of DIN 51524/25
other Hydraulic fluids on request
Fluid temperature range
(NBR) --22 ... + 176 °F (--30 ... +80 °C)
(FKM) -- 4 ... +176 °F (--20 ... +80 °C)
Ambient temperature max. ... +122 °F (... + 50 °C)
Viscosity range 98 ... 1840 SUS (20 ... 400 mm
2
/s)
Maximum degree of fluid
contamination Class 21/18/15 to ISO 4406.
Therefore we recommend a filter
with a retention rate β
10
≥ 75.
Permissible rated voltage variation AC: ± 10 %
DC: ± 10 %
Max. switching frequency 15000 1/h
Switching time, on;
at ν = 166 SUS (35 mm
2
/s) AC: 80 ... 330 ms
DC: 50 ... 120 ms
Switching time, off;
at ν = 166 SUS (35 mm
2
/s) AC: 100 ... 280 ms
DC: 30 ... 90 ms
Duty cycle 100 %
Service life 10
7
cycles
Enclosure type to DIN 40 050 IP 65
Weight-valve with 1 Solenoid 3.9 kg
valve with 2 Solenoids 5.4 kg
Mounting position optional
Technical Data
The directional control valves WL 4/10 consist of housing
(1), control spool (5), centering springs (4) and operating
solenoids (2, 3).
The three-position directional valves are fitted with two
solenoids and two springs. The two-position directional
valves have one solenoid and one return spring.
The operating solenoids are DC solenoids and are supplied
through connectors A, B (6, 7) without rectifiers. For AC
supply the solenoids are provided with rectifiers, which are
integrated directly into the connectors A, B (6, 7). The
connectors do not belong to delivery and must be ordered
Functional Description
separately. By loosening the fixing nut (8), the solenoid can
be turned on its axis and fixed in three positions 90° apart.
Provided that the pressure in T-port does not exceed
363 psi (25 bar), the spool of the valve can be repositioned
by manual override (9).
The basic surface treatment of the valve housing (1) is
phosphate coated, whereas the operating solenoids (2, 3)
are zinc coated.