©2020 ADACONN
®
+ INSERTA
®
All rights reserved. www.adaconn.com / www.inserta.com
Inserta Products, Inc.
Blue Bell, Pa. 19422
CHECK VALVES
SLIP-IN TYPE
CHECK VALVES
In applications where the valve is
subject to sudden shock opening or
closing(e.g. Accumulator System),
the nominal rated fl ow must not be
exceeded and a minimum cracking
pressure of 15 PSI is required.
NOMINAL FLOW RATES
ARE WITH A P OF
20 TO 40 PSI
MOUNTING POSITION:
OPTIONAL
MAXIMUM OPERATING PRESSURE:
5000 PSI (Contact the Factory for
pressures up to 7250 PSI)
TEMPERATURE RANGE:
–22°F (–30°C) To 175°F (80°C)
OPERATING MEDIUM: HYDRAULIC FLUID
VALVE NOMINAL A B B1* Rø 0-RING SIZE
SIZE FLOW (GPM) –.002 –.002 –.002 MAX NO. (mm)
02 2 .333 .531 .728 .024 (6.2 x 1.0)
04 5 .451 .571 .846 .039 (8.5 x 1.5)
06 10 .589 .669 .866 .078 (12.0 x 1.5)
08 18 .746 .787 .945 .078 (16.0 x 1.5)
12 24 .963 .906 1.220 .140 116
16 45 1.199 1.102 1.535 .218 213
20 75 1.553 1.653 2.434 .315 219
24 110 1.770 2.007 2.500 .394 222
32 200 2.391 2.858 3.582 .394 227
40 300 2.883 3.407 3.532 .394 231
48 400 3.385 3.507 4.119 .394 235
CAUTION
Care must be exercised when
installing check valve to insure the
free fl ow path of the slip-in check
valve is correct for the system in
which it is installed.
02 .3346 / .3360 .433 .157 .197 .531 .728 .220
04 .4528 / .4545 .551 .236 .236 .571 .846 .256
06 .5906 / .5923 .709 .315 .354 .669 .866 .374
08 .7480 / .7500 .866 .433 .433 .787 .945 .453
12 .9646 / .9666 1.102 .591 .551 .906 1.220 .571
16 1.2008 / 1.2032 1.378 .787 .787 1.102 1.535 .787
20 1.5551 / 1.5575 1.811 1.031 1.102 1.653 2.434 1.102
24 1.7717 / 1.7741 2.204 1.250 1.250 2.007 2.500 1.375
32 2.3927 / 2.3960 2.968 1.750 1.750 2.858 3.582 1.875
40 2.884 / 2.887 3.546 2.062 2.062 3.407 3.532 1.750
48 3.386 / 3.389 4.203 2.500 2.500 3.507 4.119 2.000
VALVE G H J K L L1* M
SIZE MAX. MAX. MAX. +.002 +.002 MAX.
–.000 –.000
VISCOSITY RANGE:
50 SSU TO 2000 SSU
CRACKING PRESSURE:
3 PSI, 7 PSI, 15 PSI (STANDARD)
OR 30 PSI.
* 60 PSI & 90 PSI, OPTIONAL WITH
LONGER CHECK VALVE.
NOTE: MINIMUM ORIFICE=.016 DIAMETER
45
©2018 ADACONN
®
+ INSERTA
®
All rights reserved. www.adaconn.com / www.inserta.com
Inserta Products, Inc.
Blue Bell, Pa. 19422
CHECK VALVES
SLIP-IN TYPE
CHECK VALVES
In applications where the valve is
subject to sudden shock opening or
closing(e.g. Accumulator System),
the nominal rated fl ow must not be
exceeded and a minimum cracking
pressure of 15 PSI is required.
NOMINAL FLOW RATES
ARE WITH A P OF
20 TO 40 PSI
MOUNTING POSITION:
OPTIONAL
MAXIMUM OPERATING PRESSURE:
5000 PSI (Contact the Factory for
pressures up to 7250 PSI)
TEMPERATURE RANGE:
–22°F (–30°C) To 175°F (80°C)
OPERATING MEDIUM: HYDRAULIC FLUID
VALVE NOMINAL A B B1* Rø 0-RING SIZE
SIZE FLOW (GPM) –.002 –.002 –.002 MAX NO. (mm)
02 2 .333 .531 .728 .024 (6.2 x 1.0)
04 5 .451 .571 .846 .039 (8.5 x 1.5)
06 10 .589 .669 .866 .078 (12.0 x 1.5)
08 18 .746 .787 .945 .078 (16.0 x 1.5)
12 24 .963 .906 1.220 .140 116
16 45 1.199 1.102 1.535 .218 213
20 75 1.553 1.653 2.434 .315 219
24 110 1.770 2.007 2.500 .394 222
32 200 2.391 2.858 3.582 .394 227
40 300 2.883 3.407 3.532 .394 231
48 400 3.385 3.507 4.119 .394 235
CAUTION
Care must be exercised when
installing check valve to insure the
free fl ow path of the slip-in check
valve is correct for the system in
which it is installed.
02 .3346 / .3360 .433 .157 .197 .531 .728 .220
04 .4528 / .4545 .551 .236 .236 .571 .846 .256
06 .5906 / .5923 .709 .315 .354 .669 .866 .374
08 .7480 / .7500 .866 .433 .433 .787 .945 .453
12 .9646 / .9666 1.102 .591 .551 .906 1.220 .571
16 1.2008 / 1.2032 1.378 .787 .787 1.102 1.535 .787
20 1.5551 / 1.5575 1.811 1.031 1.102 1.653 2.434 1.102
24 1.7717 / 1.7741 2.204 1.250 1.250 2.007 2.500 1.375
32 2.3927 / 2.3960 2.968 1.750 1.750 2.858 3.582 1.875
40 2.884 / 2.887 3.546 2.062 2.062 3.407 3.532 1.750
48 3.386 / 3.389 4.203 2.500 2.500 3.507 4.119 2.000
VALVE G H J K L L1* M
SIZE MAX. MAX. MAX. +.002 +.002 MAX.
–.000 –.000
VISCOSITY RANGE:
50 SSU TO 2000 SSU
CRACKING PRESSURE:
3 PSI, 7 PSI, 15 PSI (STANDARD)
OR 30 PSI.
* 60 PSI & 90 PSI, OPTIONAL WITH
LONGER CHECK VALVE.
NOTE: MINIMUM ORIFICE=.016 DIAMETER
45
©2018 ADACONN
®
+ INSERTA
®
All rights reserved. www.adaconn.com / www.inserta.com
Inserta Products, Inc.
Blue Bell, Pa. 19422
CHECK VALVES
SLIP-IN TYPE
CHECK VALVES
In applications where the valve is
subject to sudden shock opening or
closing(e.g. Accumulator System),
the nominal rated fl ow must not be
exceeded and a minimum cracking
pressure of 15 PSI is required.
NOMINAL FLOW RATES
ARE WITH A P OF
20 TO 40 PSI
MOUNTING POSITION:
OPTIONAL
MAXIMUM OPERATING PRESSURE:
5000 PSI (Contact the Factory for
pressures up to 7250 PSI)
TEMPERATURE RANGE:
–22°F (–30°C) To 175°F (80°C)
OPERATING MEDIUM: HYDRAULIC FLUID
VALVE NOMINAL A B B1* Rø 0-RING SIZE
SIZE FLOW (GPM) –.002 –.002 –.002 MAX NO. (mm)
02 2 .333 .531 .728 .024 (6.2 x 1.0)
04 5 .451 .571 .846 .039 (8.5 x 1.5)
06 10 .589 .669 .866 .078 (12.0 x 1.5)
08 18 .746 .787 .945 .078 (16.0 x 1.5)
12 24 .963 .906 1.220 .140 116
16 45 1.199 1.102 1.535 .218 213
20 75 1.553 1.653 2.434 .315 219
24 110 1.770 2.007 2.500 .394 222
32 200 2.391 2.858 3.582 .394 227
40 300 2.883 3.407 3.532 .394 231
48 400 3.385 3.507 4.119 .394 235
CAUTION
Care must be exercised when
installing check valve to insure the
free fl ow path of the slip-in check
valve is correct for the system in
which it is installed.
02 .3346 / .3360 .433 .157 .197 .531 .728 .220
04 .4528 / .4545 .551 .236 .236 .571 .846 .256
06 .5906 / .5923 .709 .315 .354 .669 .866 .374
08 .7480 / .7500 .866 .433 .433 .787 .945 .453
12 .9646 / .9666 1.102 .591 .551 .906 1.220 .571
16 1.2008 / 1.2032 1.378 .787 .787 1.102 1.535 .787
20 1.5551 / 1.5575 1.811 1.031 1.102 1.653 2.434 1.102
24 1.7717 / 1.7741 2.204 1.250 1.250 2.007 2.500 1.375
32 2.3927 / 2.3960 2.968 1.750 1.750 2.858 3.582 1.875
40 2.884 / 2.887 3.546 2.062 2.062 3.407 3.532 1.750
48 3.386 / 3.389 4.203 2.500 2.500 3.507 4.119 2.000
VALVE G H J K L L1* M
SIZE MAX. MAX. MAX. +.002 +.002 MAX.
–.000 –.000
VISCOSITY RANGE:
50 SSU TO 2000 SSU
CRACKING PRESSURE:
3 PSI, 7 PSI, 15 PSI (STANDARD)
OR 30 PSI.
* 60 PSI & 90 PSI, OPTIONAL WITH
LONGER CHECK VALVE.
NOTE: MINIMUM ORIFICE=.016 DIAMETER
45
©2018 ADACONN
®
+ INSERTA
®
All rights reserved. www.adaconn.com / www.inserta.com
CHECK VALVES
VALVE
SIZE
NOMINAL
FLOW
(GPM)
A
-.002
B
-.002
B1*
-.002
RO
MAX
O-RING SIZE
NO. (MM)
DESIGN
CODE C
O-RING SIZE
NO. (MM)
DESIGN
CODE D
02
2 .333 .531 .728 .024 (6.2 X 1.0) N/A
04 5 .451 .571 .846 .039 (8.5 X 1.5) (8.0 X 1.8)
06 10 .589 .669 .866 .078 (12.0 X 1.5) (11.2 X 1.8)
08 18 .746 .787 .945 .078 (16.0 X 1.5) 016
12 24 .963 .906 1.220 .140 116 N/A
16 45 1.199 1.102 2.434 .218 213 213
20 75 1.553 1.653 2.500 .275 219 218
24 110 1.770 2.007 2.500 .394 222 222
32 200 2.391 2.858 3.582 .394 227 227
40 300 2.883 3.407 3.532 .394 231 230
48 400 3.385 3.507 4.119 .394 235 234
VALVE
SIZE
G
H
MAX.
J
MAX.
K
MAX.
L
+.002
-.000
L1*
+.002
-.000
M
MAX.
02
.3346 / .3360 .433 .157 .197 .531 .728 .220
04 .4428 / .4545 .551 .236 .236 .571 .846 .256
06 .5906 / .5923 .709 .315 .354 .669 .866 .374
08 .7480 / .7500 .866 .433 .433 .787 .945 .453
12 .9646 / .9666 1.102 .551 .551 .906 1.220 .571
16 1.2008 / 1.2032 1.378 .787 .787 1.102 1.535 .787
20 1.5551 / 1.5575 1.811 1.102 1.102 1.653 2.434 1.102
24 1.7717 / 1.7741 2.204 1.250 1.250 2.007 2.500 1.375
32 2.3927 / 2.3960 2.968 1.750 1.750 2.858 3.582 1.875
40 2.884 / 2.887 3.546 2.062 2.062 3.407 3.532 1.750
48 3.386 / 3.389 4.205 2.500 2.500 3.507 4.119 2.000
NOTE: MINIMUM ORIFICE=.016 DIAMETER
In applications where the valve is subject
to sudden shock opening or closing (e.g.
Accumulator System), the nominal rated
ow must not be exceeded and a minimum
cracking pressure of 15 PSI is required.
MACHINED CAVITY DIMENSIONS
SURFACE FINISH TO BE 63
TEE BRANCH RIGHT ANGLE STRAIGHT THRU
(COMBINATIONS OF THESE CAVITIES CAN BE USED)
MOUNTING POSITION:
OPTIONAL
MAXIMUM OPERATING PRESSURE:
5000 PSI (Contact the Factory for
pressures up to 7250 PSI)
TEMPERATURE RANGE:
-22°F (-30°C) TO 175°F (80°C)
OPERATING MEDIUM: HYDRAULIC FLUID
VISCOSITY RANGE:
50 SSU TO 2000 SSU
CRACKING PRESSURE:
3 PSI, 7 PSI, 15 PSI (STANDARD)
OR 30 PSI.
* 60 PSI & 90 PSI, OPTIONAL WITH
LONGER CHECK VALVE.
NOMINAL FLOW RATES
ARE WITH A rP OF
20 TO 40 PSI
CAUTION
Care must be exercised when
installing check valve to insure the
free ow path of the slip-in check
valve is correct for the system in
which it is installed.
47