DMP 333
Industrial Pressure Transmitter Technical Data
pressure and level
1
[bar]
60 100 160 250 400 600
1
measurement starts with ambient pressure
2-wire: 4 ... 20 mA / V
S
= 8 ... 32 V
DC
2-wire: 4 ... 20 mA / V
S
= 10 ... 28 V
DC
S
DC
0 ... 10 V / V
S
= 14 ... 30 V
DC
option 1: ≤ ± 0.25 % FSO
max
S
S
current 3-wire: R
max
= 500 Ω
voltage 3-wire: R
min
= 10 kΩ
supply: 0.05 % FSO / 10 V
load: 0.05 % FSO / kΩ
≤ ± 0.1 % FSO / year at reference conditions
2-wire: ≤ 10 msec
3-wire: ≤ 3 msec
2
accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)
Thermal effects (Offset and Span)
electronics / environment: -40 ... 85 °C
Reverse polarity protection
no damage, but also no function
Electromagnetic compatibility
emission and immunity according to EN 61326
10 g RMS (25 ... 2000 Hz) according to DIN EN 60068-2-6
100 g / 11 msec according to DIN EN 60068-2-27
stainless steel 1.4404 (316 L)
stainless steel 1.4404 (316 L)
Option compact field housing
stainless steel 1.4305 (303), cable gland brass, nickel plated others on request
options: EPDM (for P
N
≤ 160 bar)
NBR
stainless steel 1.4435 (316 L)
pressure port, seals, diaphragm
Explosion protection (only for 4 ... 20 mA / 2-wire)
DX19-DMP 333
IBExU 10 ATEX 1068 X / IECEx IBE 12.0027X
zone 0: II 1G Ex ia IIC T4 Ga
zone 20: II 1D Ex ia IIIC T 85°C Da
Safety technical maximum values
U
i
= 28 V
DC
, I
i
= 93 mA, P
i
= 660 mW, C
i
≈ 0 nF, L
i
≈ 0 µH,
the supply connections have an inner capacity of max. 27 nF to the housing
Permissible temperatures for
environment
in zone 0: -20 ... 60 °C with p
atm
0.8 bar up to 1.1 bar
in zone 1 or higher: -20 ... 70 °C
Connecting cables (by factory)
cable capacitance: signal line/shield also signal line/signal line: 160 pF/m
cable inductance: signal line/shield also signal line/signal line: 1µH/m