Videoconferecing IP
www.ikron.it
E-mail: info@ikron.it
HF 620 / HF 625 series
Suction and return in line Spin-On filters
THE IMPORTANCE OF AN EFFICIENT FILTRATION
The main cause of anomalies in hydraulic systems has to
be attributed to the presence of contaminants in the fluid.
The nature of the contaminant may be: gaseous, namely
air mixed with the fluid; fluid, it depends on water
penetrating the fluid; solid, therefore particles of various
origins and dimensions.
Customers who operate equipments are always focused
on obtaining the best possible performance, lower
energy consumptions and greater respect for the
environment.
These characteristics can be attained by using top
quality components in the hydraulic system, which are
more sensitive to the presence of contaminants in the
fluid.
Starting from these requirements, we understand how
important and fundamental it is to prevent the presence
of air and water from mixing in the fluid tank by using
dedicated solutions.
It is also crucial to limit the presence of solid particles in
the hydraulic circuit through a suitable filtering system,
which is indispensable to maintain the project
requirements of the system over time and to keep
running costs low.
The correct choice of a filter and its optimum position in
the hydraulic system requires the same care and
experience needed to choose all the other components.
The use of filters with larger filtering surfaces reduces, at
equal flow rates, the superficial contaminant load and
therefore the filter's life is extended proportionally.
To maintain the maximum efficiency of the system, the
filters must have a clogging indicator showing the
differential pressure on the filtering cartridge and to
immediately point out when the cartridge needs
replacing in order to prevent the by-pass valve from
opening.
The following factors should be analysed when choosing the ideal filter:
Ø
The filtration degree required to protect the most sensitive component from contamination
Ø
The points of the circuit in which the filters have to be installed
Ø
The working pressure of the system
Ø
The maximum flow rate and the type of fluid to be filtered
Ø
The duty cycle
Ø
The retention efficiency of the filtering cartridge
Ø
The contaminant accumulation capacity of the filtering cartridge
Ø
The working ambient temperature
Each filter used generates a pressure drop that increases continuously as time goes by. This pressure drop represents
an efficiency index of the filter itself.
When the hydraulic system is about to be assembled, all the components must be perfectly clean and the fluid has to be
added through a device complete with a filter.
During the test phase, it is advisable to run some work cycles at low pressure in order to create the best possible condi
-
tions for all the components.
HF 620 / HF 625
ICAT008-002 002 1
TECHNICAL CHARACTERISTICS
01/03.2011
HF 620 filter series are directly connected to the suction line or return line of hydraulic circuit.
HF 625 filter series can be used in applications with 363 psi (25 bar) working pressure.
Both series safeguard the hydraulic circuit from contaminating particles.
l
Flow up to 50 US gpm (190 l/min) on the suction line and 92 US gpm (350 l/min) on
the return line
l
363 psi (25 bar) maximum working pressure
l
Quick replacement of the filtering element
MATERIALS
Head Aluminum
Bowl Steel
Seals Buna - Viton
End cap Zinc plated steel
Inner tube Zinc plated steel
Stainless steel
Filter media Cellulose
Micro-fibre glass
FLUID COMPATIBILITY
Conforming to ISO 2943 (Norm ISO 6743/4)
Oli mineral (1) HH - HL - HM - HR - HV - HG
Water emulsion (1) HFAE - HFAS
Syntetic fluid (2) HS - HFDR - HFDU - HFDS
(1)
With Buna seals
(2) With Viton seals
FLOW
Max. flow (Suction) 50 US gpm (190 l/min)
Max. flow (Return) 92 US gpm (350 l/min)
PRESSURE
HF 620
Working pressure 174 psi (12 bar)
Testing pressure 232 psi (16 bar)
Burst pressure 305 psi (21 bar)
Element collapse pressure rating
(conforming to ISO 2941)
72.5 psi (5 bar)(only cellulose
element)
145 psi (10 bar)
HF 625
Working pressure 363 psi (25 bar)
Testing pressure 435 psi (30 bar)
Burst pressure 653 psi (45 bar)
Element collapse pressure rating
(conforming to ISO 2941)
72.5 psi (5 bar)(only cellulose
element)
145 psi (10 bar)
BY-PASS VALVE
By-pass setting 2.9 psi (0,2 bar) (Suction)
By-pass setting 25 psi (1,7 bar) (Return)
OPERATING TEMPERATURE
With Buna seals
-22 ¸ 195 °F (-30 ¸ 90 °C)
With Viton seals
-4 ¸ 230 °F (-20 ¸ 110 °C)
INDICATORS (3)
Rear manometer
Visual indicator
Electrical indicator
Visual diffential indicator
Visual electrical differential indicator
(3)
Characteristics and dimensions at page 20 and 21
DEGREE OF FILTRATION
Absolute Filtration
Code
Material
Degree of filtration
FG010 Micro-fibre glass
10 mm
FG025 Micro-fibre glass
25 m m
Nominal Filtration
Code
Material
Degree of filtration
SP010 Cellulose
10 mm
SP025 Cellulose
25 mm
MS060 Steel
60 mm
MS090 Steel
90 mm
HF 620 / HF 625
2 002 ICAT008-002
01/03.2011
SIZING – PRESSURE DROP
The total pressure drop of the filter is calculated by summing the pressure drop value in the housing to the one in the fil
-
tering element.
Total Dp =Dp in housing + Dp in element
In filters of HF 620 series in normal working conditions, the total Dp must not be more than 1.4 psi (0,1 bar) on suction
line and 5.8 (0,4 bar) on return line.
In filters of HF 625 series in normal working conditions, the total Dp must not be more than 5.8 psi (0,4 bar).
To establish the values of pressure drop involved, the following pages provide some diagrams with curves referred to
the use of mineral oils SAE 10 with kinematic viscosity of 120 SSU (30 cSt) and density of 7.29 lb/gal (0,856 kg/dm
3
).
Calculation example
Filter HF620-30.155-AS-FG010-B17-GG-B-XB-DA-G
Flow rate= 29 US gpm (110 l/min)
Kinematic viscosity: 120 SSU (30 cSt)
Oil density : 7.29 lb/gal (0,856 kg/dm
3
)
Filtering degree: 10 mm
Data obtained from the diagrams:
Dp in housing = 1.45 psi (0,10 bar) (page 5)
Dp in element = 3.77 psi (0,26 bar) (page 8)
Total Dp = 1.45 + 3.77 = 5.22 psi (0,36 bar) (Dp is lower than maximum value admitted – therefore sizing is correct).
If oil with different kinematic viscosity and different density is used, the values obtained from the diagrams will be re-cal-
culated considering the following indications:
1) The pressure drop of the housing is proportional with the oil density, therefore for oil with density different to 7.29
lb/gal (0,856 kg/dm
3
) the value of the Dp in the head-bowl will be:
Dp in housing =
Dp of diagram (psi)
• Oil density ( lb/gal)
[psi]
7.29 (lb/gal)
Or
Dp in housing =
Dp of diagram (bar)
• Oil density ( kg/dm
3
)
[bar]
0,856 (kg/dm
3
)
2) The pressure drop of the element is proportional with the oil density and kinematic viscosity, therefore for oil with
density different to 7.29 lb/gal (0,856 kg/dm
3
) and kinematic viscosity different to 120 SSU (30 cSt) the value of Dp in the
element will be:
Dpinelement = Dp of diagram (psi)
•
Oil density (lb/gal)
•
Oil viscosity (SSU)
[psi]
7.29 (lb/gal) 120 (SSU)
Or
Dpinelement = Dp of diagram (bar)
•
Oil density (kg/dm
3
)
•
Oil viscosity (cSt)
[bar]
0,856 (kg/dm
3
)30(cSt)
Now you sum the values of the pressure drop of the housing to the value of the pressure drop of the filtering element,
always making sure the total Dp does not exceed the pressure indicated above.
HF 620 / HF 625
ICAT008-002 002 3
01/03.2011
PRESSURE DROP CURVES THROUGH THE BY-PASS VALVES B02
The pressure drop values are directly proportional with
the specific weight of the fluid and do not affect the
establishment of the total pressure drop of the complete
filter.
The curves are obtained in the following conditions:
Mineral oil type SAE 10
Kinematic viscosity 120 SSU (30 cSt)
Density 7.29 lb/gal (0,856 kg/dm
3
).
HF 620-20 / HF 625-20 HF 620-30 / HF 625-30
0
0,5
(7.25)
1,0
(14.50)
1,5
(21.75)
2,0
(29.00)
2,5
(36,25)
0
5
(1.3)
10
(2.6)
15
(4.0)
20
(5.3)
25
(6.6)
30
(7.9)
35
(9.2)
40
(10.6)
45
(11.9)
50
(13.2)
0
0,5
(7.25)
1,0
(14.50)
1,5
(21.75)
2,0
(29.00)
2,5
(36,25)
0
15
(4.0)
30
(7.9)
45
(11.9)
60
(15.9)
75
(19.8)
90
(23.8)
105
(27.7)
120
(31.7)
135
(35.7)
150
(39.6)
HF 620-40 / HF 620-50
0
0,5
(7.25)
1,0
(14.50)
1,5
(21.75)
2,0
(29.00)
2,5
(36,25)
0
25
(6.6)
50
(13.2)
75
(19.8)
100
(26.4)
125
(33.0)
150
(39.6)
175
(46.2)
200
(52.8)
225
(59.4)
250
(66.0)
HF 620 / HF 625
4 002 ICAT008-002
PRESSURE DROP CURVES THROUGH THE BY-PASS VALVES B17
The pressure drop values are directly proportional with
the specific weight of the fluid and do not affect the
establishment of the total pressure drop of the complete
filter.
The curves are obtained in the following conditions:
Mineral oil type SAE 10
Kinematic viscosity 120 SSU (30 cSt)
Density 7.29 lb/gal (0,856 kg/dm
3
).
01/03.2011
HF 620-20 / HF 625-20
0
1,0
(14.50)
2,0
(29.00)
3,0
(43.50)
4,0
(58.00)
5,0
(72,50)
0
10
(2.6)
20
(5.3)
30
(7.9)
40
(10.6)
50
(13.2)
60
(15.8)
70
(18.5)
80
(21.1)
90
(23.8)
100
(26.4)
HF 620-30 / HF 625-30
0
1,0
(14.50)
2,0
(29.00)
3,0
(43.50)
4,0
(58.00)
5,0
(72,50)
0
30
(7.9)
60
(15.9)
90
(23.8)
120
(31.7)
150
(39.6)
180
(47.6)
210
(55.5)
240
(63.4)
270
(71.3)
300
(79.2)
HF 620-40 / HF 620-50
0
1,0
(14.50)
2,0
(29.00)
3,0
(43.50)
4,0
(58.00)
5,0
(72,50)
0
50
(13.2)
100
(26.4)
150
(39.6)
200
(52.8)
250
(66.0)
300
(79.2)
350
(92.4)
400
(105.7)
450
(118.9)
500
(132.0)
HF 620 / HF 625
ICAT008-002 002 5
01/03.2011
PRESSURE DROP CURVES THROUGH THE HOUSING
The curves are obtained in the following conditions:
Mineral oil type SAE 10
Kinematic viscosity 120 SSU (30 cSt)
Density 7.29 lb/gal (0,856 kg/dm
3
).
Series 20 G 3/4
Series 30 G 1 1/4
Series 40 / 50 G 1 1/2
HF 620-20 / HF 625-20
0
0,1
(1.45)
0,2
(2.90)
0,3
(4.35)
0,4
(5.80)
0,5
(7.25)
0
10
(2.6)
20
(5.3)
30
(7.9)
40
(10.6)
50
(13.2)
60
(15.8)
70
(18.5)
80
(21.1)
90
(23.8)
100
(26.4)
HF 620-30 / HF 625-30
0
0,1
(1.45)
0,2
(2.90)
0,3
(4.35)
0,4
(5.80)
0,5
(7.25)
0
30
(7.9)
60
(15.8)
90
(23.8)
120
(31.7)
150
(39.6)
180
(47.6)
210
(55.5)
240
(63.4)
270
(71.3)
300
(79.2)
HF 620-40 / HF 620-50
0
0,1
(1.45)
0,2
(2.90)
0,3
(4.35)
0,4
(5.80)
0,5
(7.25)
0
50
(13.2)
100
(26.4)
150
(39.6)
200
(52.8)
250
(66.0)
300
(79.2)
350
(92.5)
400
(105.7)
450
(118.9)
500
(132.0)
HF 620 / HF 625
6 002 ICAT008-002
01/03.2011
PRESSURE DROP CURVES THROUGH THE ELEMENT HE K45/46-20
The curves are obtained in the following conditions:
Mineral oil type SAE 10
Kinematic viscosity 120 SSU (30 cSt)
Density 7.29 lb/gal (0,856 kg/dm
3
).
(1) HE K45-20.135 / HE K46-20.135
(2) HE K45-20.180 / HE K46-20.180
FG010
(2)
(1)
0
0,1
(1.45)
0,2
(2.90)
0,3
(4.35)
0,4
(5.80)
0,5
(7.25)
0
10
(2.6)
20
(5.3)
30
(7.9)
40
(10.6)
50
(13.2)
60
(15.8)
70
(18.5)
80
(21.1)
90
(23.8)
100
(26.4)
FG025
(2)
(1)
0
0,1
(1.45)
0,2
(2.90)
0,3
(4.35)
0,4
(5.80)
0,5
(7.25)
0
10
(2.6)
20
(5.3)
30
(7.9)
40
(10.6)
50
(13.2)
60
(15.8)
70
(18.5)
80
(21.1)
90
(23.8)
100
(26.4)
(2)
(1)
0
0,05
(0.72)
0,1
(1.45)
0,15
(2.17)
0,2
(2.90)
0,25
(3.62)
0
10
(2.6)
20
(5.3)
30
(7.9)
40
(10.6)
50
(13.2)
60
(15.8)
70
(18.5)
80
(21.1)
90
(23.8)
100
(26.4)
SP025
(2)
(1)
0
0,05
(0.72)
0,1
(1.45)
0,15
(2.17)
0,2
(2.90)
0,25
(3.62)
0
10
(2.6)
20
(5.3)
30
(7.9)
40
(10.6)
50
(13.2)
60
(15.8)
70
(18.5)
80
(21.1)
90
(23.8)
100
(26.4)
SP010
HF 620 / HF 625
ICAT008-002 002 7
01/03.2011
PRESSURE DROP CURVES THROUGH THE ELEMENT HE K45/46-20
The curves are obtained in the following conditions:
Mineral oil type SAE 10
Kinematic viscosity 120 SSU (30 cSt)
Density 7.29 lb/gal (0,856 kg/dm
3
).
(1) HE K45-20.135 / HE K46-20.135
(2) HE K45-20.180 / HE K46-20.180
MS060
(2)
(1)
0
0,02
(0.29)
0,04
(0.58)
0,06
(0.87)
0,08
(1.16)
0,1
(1.45)
0
10
(2.6)
20
(5.3)
30
(7.9)
40
(10.6)
50
(13.2)
60
(15.8)
70
(18.5)
80
(21.1)
90
(23.8)
100
(26.4)
MS090
(2)
(1)
0
0,02
(0.29)
0,04
(0.58)
0,06
(0.87)
0,08
(1.16)
0,1
(1.45)
0
10
(2.6)
20
(5.3)
30
(7.9)
40
(10.6)
50
(13.2)
60
(15.8)
70
(18.5)
80
(21.1)
90
(23.8)
100
(26.4)
HF 620 / HF 625
8 002 ICAT008-002
01/03.2011
PRESSURE DROP CURVES THROUGH THE ELEMENT HE K45/46-30
The curves are obtained in the following conditions:
Mineral oil type SAE 10
Kinematic viscosity 120 SSU (30 cSt)
Density 7.29 lb/gal (0,856 kg/dm
3
).
(1) HE K45-30.155 / HE K46-30.155
(2) HE K45-30.210 / HE K46-30.210
(3) HE K45-30.305 / HE K46-30.305
FG010 FG025
(3)
(2)
(1)
0
0,1
(1.45)
0,2
(2.90)
0,3
(4.35)
0,4
(5.80)
0,5
(7.25)
0
30
(7.9)
60
(15.9)
90
(23.8)
120
(31.7)
150
(39.6)
180
(47.6)
210
(55.5)
240
(63.4)
270
(71.3)
300
(79.2)
(3)
(2)
(1)
0
0,1
(1.45)
0,2
(2.90)
0,3
(4.35)
0,4
(5.80)
0,5
(7.25)
0
30
(7.9)
60
(15.9)
90
(23.8)
120
(31.7)
150
(39.6)
180
(47.6)
210
(55.5)
240
(63.4)
270
(71.3)
300
(79.2)
SP010 SP025
(3)
(2)
(1)
0
0,05
(0.72)
0,1
(1.45)
0,15
(2.17)
0,2
(2.90)
0,25
(3.62)
0
30
(7.9)
60
(15.9)
90
(23.8)
120
(31.7)
150
(39.6)
180
(47.6)
210
(55.5)
240
(63.4)
270
(71.3)
300
(79.2)
(3)
(2)
(1)
0
0,05
(0.72)
0,1
(1.45)
0,15
(2.17)
0,2
(2.90)
0,25
(3.62)
0
30
(7.9)
60
(15.8)
90
(23.8)
120
(31.7)
150
(39.6)
180
(47.6)
210
(55.5)
240
(63.4)
270
(71.3)
300
(79.2)
HF 620 / HF 625
ICAT008-002 002 9
01/03.2011
The curves are obtained in the following conditions:
Mineral oil type SAE 10
Kinematic viscosity 120 SSU (30 cSt)
Density 7.29 lb/gal (0,856 kg/dm
3
).
(1) HE K45-30.155 / HE K46-30.155
(2) HE K45-30.210 / HE K46-30.210
(3) HE K45-30.305 / HE K46-30.305
MS060 MS090
(3)
(2)
(1)
0
0,02
(0.29)
0,04
(0.58)
0,06
(0.87)
0,08
(1.16)
0,1
(1.45)
0
30
(7.9)
60
(15.9)
90
(23.8)
120
(31.7)
150
(39.6)
180
(47.6)
210
(55.5)
240
(63.4)
270
(71.3)
300
(79.2)
(3)
(2)
(1)
0
0,02
(0.29)
0,04
(0.58)
0,06
(0.87)
0,08
(1.16)
0,1
(1.45)
0
30
(7.9)
60
(15.9)
90
(23.8)
120
(31.7)
150
(39.6)
180
(47.6)
210
(55.5)
240
(63.4)
270
(71.3)
300
(79.2)
PRESSURE DROP CURVES THROUGH THE ELEMENT HE K45/46-30
HF 620 / HF 625
10 002 ICAT008-002
01/03.2011
SUCTION FILTERS FLOWS
Degree of filtration
FG010 FG025 SP010 SP025
Filter type
Inlet ports
Flow
Dp= 1.45 psi (0,1 bar) (values referred to standard filtering surfaces)
GAS
(BSPP)
NPT SAE J514b US gpm (l/min)
HF 620-20.135
HF 625-20.135
G 3/4 3/4 NPT 1 1/16-12 UNF-2B 5.3 (25) 9.2 (35) 7.9 (30) 9.2 (35)
HF 620-20.180
HF 625-20.180
G 3/4 3/4 NPT 1 1/16-12 UNF-2B 5.3 (25) 9.2 (35) 9.2 (35) 10.6 (40)
HF 620-30.155
HF 625-30.155
G 1 1/4 1 1/4 NPT 1 5/8-12 UNF-2B 14.5 (55) 21.1 (80) 19.8 (75) 23.8 (90)
HF 620-30.210
HF 625-30.210
G 1 1/4 1 1/4 NPT 1 5/8-12 UNF-2B 15.8 (60) 23.8 (90) 21.1 (80) 26.4 (100)
HF 620-30.305
HF 625-30.305
G 1 1/4 1 1/4 NPT 1 5/8-12 UNF-2B 18.5 (70) 25.1 (95) 26.4 (100) 27.7 (105)
HF 620-40.155
HF 620-50.155
G 1 1/2 1 1/2 NPT 1 7/8-12 UNF-2B 18.5 (70) 31.7 (120) 26.4 (100) 37.0 (140)
HF 620-40.210
HF 620-50.210
G 1 1/2 1 1/2 NPT 1 7/8-12 UNF-2B 23.8 (90) 34.3 (130) 34.3 (130) 39.6 (150)
HF 620-40.305
HF 620-50.305
G 1 1/2 1 1/2 NPT 1 7/8-12 UNF-2B 26.4 (100) 37.0 (140) 39.6 (150) 42.3 (160)
Degree of filtration
MS060 MS090
Filter type
Inlet ports
Flow
Dp= 1.45 psi (0,1 bar) (values referred to standard filtering surfaces)
GAS
(BSPP)
NPT SAE J514b US gpm (l/min)
HF 620-20.135
HF 625-20.135
G 3/4 3/4 NPT 1 1/16-12 UNF-2B 10.6 (40) 11.9 (45)
HF 620-20.180
HF 625-20.180
G 3/4 3/4 NPT 1 1/16-12 UNF-2B 10.6 (40) 11.9 (45)
HF 620-30.155
HF 625-30.155
G 1 1/4 1 1/4 NPT 1 5/8-12 UNF-2B 26.4 (100) 27.7 (105)
HF 620-30.210
HF 625-30.210
G 1 1/4 1 1/4 NPT 1 5/8-12 UNF-2B 27.7 (105) 29.0 (110)
HF 620-30.305
HF 625-30.305
G 1 1/4 1 1/4 NPT 1 5/8-12 UNF-2B 29.0 (110) 30.4 (115)
HF 620-40.155
HF 620-50.155
G 1 1/2 1 1/2 NPT 1 7/8-12 UNF-2B 42.3 (160) 44.9 (170)
HF 620-40.210
HF 620-50.210
G 1 1/2 1 1/2 NPT 1 7/8-12 UNF-2B 44.9 (170) 47.5 (180)
HF 620-40.305
HF 620-50.305
G 1 1/2 1 1/2 NPT 1 7/8-12 UNF-2B 47.5 (180) 50.2 (190)
HF 620 / HF 625
ICAT008-002 002 11
01/03.2011
RETURN FILTERS FLOWS
Degree of filtration
FG010 FG025 SP010 SP025
Filter type
Inlet ports
Flow
Dp= 5.8 psi(0,4 bar) (values referred to standard filtering surfaces)
GAS
(BSPP)
NPT SAE J514b US gpm (l/min)
HF 620-20.135
HF 625-20.135
G 3/4 3/4 NPT 1 1/16-12 UNF-2B 17.2 (65) 19.8 (75) 17.2 (65) 19.8 (75)
HF 620-20.180
HF 625-20.180
G 3/4 3/4 NPT 1 1/16-12 UNF-2B 17.2 (65) 19.8 (75) 19.8 (75) 21.1 (80)
HF 620-30.155
HF 625-30.155
G 1 1/4 1 1/4 NPT 1 5/8-12 UNF-2B 33.0 (125) 47.5 (180) 43.6 (165) 51.5 (195)
HF 620-30.210
HF 625-30.210
G 1 1/4 1 1/4 NPT 1 5/8-12 UNF-2B 38.3 (145) 50.2 (190) 47.5 (180) 52.8 (200)
HF 620-30.305
HF 625-30.305
G 1 1/4 1 1/4 NPT 1 5/8-12 UNF-2B 42.3 (160) 52.8 (200) 52.8 (200) 55.5 (210)
HF 620-40.155
HF 620-50.155
G 1 1/2 1 1/2 NPT 1 7/8-12 UNF-2B 44.9 (170) 71.3 (270) 60.8 (230) 79.2 (300)
HF 620-40.210
HF 620-50.210
G 1 1/2 1 1/2 NPT 1 7/8-12 UNF-2B 50.2 (190) 76.6 (290) 71.3 (270) 81.9 (310)
HF 620-40.305
HF 620-50.305
G 1 1/2 1 1/2 NPT 1 7/8-12 UNF-2B 60.8 (230) 81.9 (310) 81.9 (310) 89.8 (340)
Degree of filtration
MS060 MS090
Filter type
Inlet ports
Flow
Dp= 5.8 psi (0,4 bar) (values referred to standard filtering surfaces)
GAS
(BSPP)
NPT SAE J514b US gpm (l/min)
HF 620-20.135
HF 625-20.135
G 3/4 3/4 NPT 1 1/16-12 UNF-2B 21.1 (80) 22.4 (85)
HF 620-20.180
HF 625-20.180
G 3/4 3/4 NPT 1 1/16-12 UNF-2B 21.1 (80) 22.4 (85)
HF 620-30.155
HF 625-30.155
G 1 1/4 1 1/4 NPT 1 5/8-12 UNF-2B 54.1 (205) 56.8 (215)
HF 620-30.210
HF 625-30.210
G 1 1/4 1 1/4 NPT 1 5/8-12 UNF-2B 55.5 (210) 58.1 (220)
HF 620-30.305
HF 625-30.305
G 1 1/4 1 1/4 NPT 1 5/8-12 UNF-2B 56.8 (215) 59.4 (225)
HF 620-40.155
HF 620-50.155
G 1 1/2 1 1/2 NPT 1 7/8-12 UNF-2B 84.5 (320) 87.1 (330)
HF 620-40.210
HF 620-50.210
G 1 1/2 1 1/2 NPT 1 7/8-12 UNF-2B 87.1 (330) 89.8 (340)
HF 620-40.305
HF 620-50.305
G 1 1/2 1 1/2 NPT 1 7/8-12 UNF-2B 89.8 (340) 92.5 (350)
HF 620 / HF 625
12 002 ICAT008-003
01/03.2011
HF 620-20 DIMENSIONS
Filter type
Weight A B C D
(1)(3)(GAS-BSPP)
Suction indicators
(2)(4)(GAS-BSPP)
Return indicators
kg(lbs) mm(in) mm(in) (GAS-BSPP) mm(in)
HF 620-20.135
1,05
(2.31)
195
(7.6771)
215
(8.4645)
G3/4
147
(5.7873)
G1/8 G1/8
HF 620-20.180
1,28
(2.82)
257
(10.1180)
277
(10.9054)
209
(8.2283)
NPT, metric and SAE UN-UNF threads are available (consult our technical department).
HF 620 / HF 625
ICAT008-003 002 13
01/03.2011
HF 620-30 DIMENSIONS
Filter type
Weight A B C D E
(1)(3)(GAS-BSPP)
Suction indicators
(2)(4)(GAS-BSPP)
Return indicators
kg(lbs) mm(in) mm(in) (GAS-BSPP) mm(in) mm(in)
HF 620-30.155
1,87
(4.12)
243
(9.5669)
268
(10.5511)
G11/4
179
(7.0472)
126
(4.9606)
G1/8 G1/8
HF 620-30.210
2,17
(4.78)
291
(11.4566)
316
(12.4409)
227
(8.9369)
HF 620-30.305
3,15
(6.94)
373
(14.6850)
398
(15.6692)
309
(12.1653)
138
(5.4330)
NPT, metric and SAE UN-UNF threads are available (consult our technical department).
HF 620 / HF 625
14 002 ICAT008-003
HF 620-40 DIMENSIONS
01/03.2011
Filter type
Weight A B C D E
(1)(GAS-BSPP)
Suction indicators
(2)(GAS-BSPP)
Return indicators
(5)(GAS-BSPP)
Differential indicators
kg(lbs) mm(in) mm(in) (GAS-BSPP) mm(in) mm(in)
HF 620-40.155
3,31
(7.29)
214
(8.4251)
249
(9.8031)
G11/2
181
(7.1259)
126
(4.9606)
G 1/8 G 1/8 G 1/2
HF 620-40.210
3,89
(8.57)
262
(10.3149)
297
(11.6928)
229
(9.0157)
HF 620-40.305
5,85
(12.89)
344
(13.5432)
379
(14.9212)
311
(12.2440)
138
(5.4330)
NPT, metric and SAE UN-UNF threads are available (consult our technical department).
HF 620 / HF 625
ICAT008-003 002 15
01/03.2011
HF 620-50 DIMENSIONS
Filter type
Weight A B C D E
(1)(GAS-BSPP)
Suction indicators
(2)(GAS-BSPP)
Return indicators
(5)(GAS-BSPP)
Differential indicators
kg(lbs) mm(in) mm(in) (GAS-BSPP) mm(in) mm(in)
HF 620-50.155
5,25
(11.57)
264
(10.3936)
299
(11.7716)
G11/2
179
(7.0472)
126
(4.9606)
G 1/8 G 1/8 G 1/2
HF 620-50.210
5,84
(12.87)
312
(12.2834)
347
(13.6613)
227
(8.9369)
HF 620-50.305
7,79
(17.17)
394
(15.5117)
429
(16.8897)
309
(12.1653)
138
(5.4330)
NPT, metric, SAE UN-UNF and SAE3000 threads are available (consult our technical department).
HF 620 / HF 625
16 002 ICAT008-003
01/03.2011
HF 625-20 DIMENSIONS
Filter type
Weight A B C D
kg(lbs) mm(in) mm(in) (GAS-BSPP) mm(in)
HF 625-20.135
1,24
(2.73)
195
(7.6771)
215
(8.4645)
G3/4
147
(5.7873)
HF 625-20.180
1,44
(3.17)
257
(10.1180)
277
(10.9054)
209
(8.2283)
NPT, metric and SAE UN-UNF threads are available (consult our technical department).
HF 620 / HF 625
ICAT008-003 002 17
01/03.2011
HF 625-30 DIMENSIONS
Filter type
Weight A B C D
kg(lbs) mm(in) mm(in) (GAS-BSPP) mm(in)
HF 625-30.155
1,95
(4.29)
238
(9.3700)
262
(10.3149)
G11/4
174
(6.8503)
HF 625-30.210
2,25
(4.96)
293
(11.5354)
317
(12.4802)
229
(9.0157)
HF 625-30.305
3,23
(7.12)
373
(14.6850)
398
(15.6692)
309
(12.1653)
NPT, metric and SAE UN-UNF threads are available (consult our technical department).
HF 620 / HF 625
18 002 ICAT008-003
01/03.2011
ELEMENTS DIMENSIONS FOR HF 620
Element type
AØBØC
Filtering surface
FG MS SP
mm(in) (GAS-BSSP) mm(in) cm
2
(in
2
)cm
2
(in
2
)cm
2
(in
2
)
HE K45-20.135
148
(5.8267)
G 3/4
96
(3.7795)
1700
(263.5005)
785
(121.6752)
2440
(378.2008)
HE K45-20.180
210
(8.2676)
2125
(329.3757)
1275
(197.6254)
3960
(613.8012)
HE K45-30.155
180
(7.0865)
G 1 1/4
126
(4.9606)
4410
(683.5514)
1650
(255.7505)
4970
(770.3515)
HE K45-30.210
228
(8.9763)
5980
(926.9019)
2190
(339.4507)
6730
(1043.1520)
HE K45-30.305
310
(12.2046)
138
(5.4330)
7900
(1224.5020)
4450
(689.7514)
13580
(2104.9040)
HF 620 / HF 625
ICAT008-003 002 19
01/03.2011
ELEMENTS DIMENSIONS FOR HF 625
Element type
AØBØC
Filtering surface
FG MS SP
mm(in) (GAS-BSSP) mm(in) cm
2
(in
2
)cm
2
(in
2
)cm
2
(in
2
)
HE K46-20.135
148
(5.8267)
G 3/4
96
(3.7795)
1700
(263.5005)
785
(121.6752)
2440
(378.2008)
HE K46-20.180
210
(8.2676)
2125
(329.3757)
1275
(197.6254)
3960
(613.8012)
HE K46-30.155
175
(6.8897)
G 1 1/4
138
(5.4330)
3580
(554.9011)
2035
(315.4256)
4480
(694.4014)
HE K46-30.210
230
(9.0550)
6250
(968.7519)
3200
(496.0010)
6120
(948.6019)
HE K46-30.305
310
(12.2046)
7900
(1224.5020)
4450
(689.7514)
13580
(2104.9040)
HF 620 / HF 625
20 002 ICAT008-003
01/03.2011
INDICATORS FOR SUCTION LINE
REAR MANOMETER
Code: M
VISUAL INDICATOR
Code: V
Scale -14.5 ÷ 0 psi (-1 ÷ 0 bar) Pressure setting -2.2 psi (-0,15 bar)
ELECTRICAL INDICATOR
Code: E
1
23
Pressure setting -2.2 psi (-0,15 bar)
Max. working voltage
220 VCA
30 VCC
Max. working current
0,5 A (resistivity)
0,2 A (inductive)
Protection class IP65
Contacts N.O. and N.C.
HF 620 / HF 625
ICAT008-003 002 21
01/03.2011
INDICATORS FOR RETURN LINE
DIFFERENTIAL VISUAL INDICATOR
Code: D
(only for 20 and 30 series)
Pressure setting 21.8 psi (1,5 bar)
DIFFERENTIAL VISUAL INDICATOR
Code: H
(only for 40 and 50 series)
Pressure setting 21.8 psi (1,5 bar)
DIFFENTIAL ELECTRICAL-VISUAL INDICATOR
Code: L
(only for 40 and 50 series)
Pressure setting 21.8 psi (1,5 bar)
Max. working voltage
220 VCA
30 VCC
Max. working current
0,5 A (resistivity)
0,2 A (inductive)
Protection class IP65
Contacts N.O. and N.C.
132
N.C.
N.O.
HF 620 / HF 625
22 002 ICAT008-003
01/03.2011
IN / OUT PORTS
GAS THREAD
BSPP
Cylindrical GAS thread (55°) in accordance with UNI - ISO 228
CODE
Nominal
size
A
Æ B
C
mm (in) mm (in) Nm (lbf in)
GE
3/4" G 3/4
24,5
(0.9645)
20
(0.7873)
30
+2,5
(266 ÷ 288)
GG
1" 1/4 G 1 1/4
39
(1.5354)
24
(0.9448)
60
+5
(531 ÷ 575)
GH
1" 1/2 G 1 1/2
45
(1.7716)
26
(1.0236)
70
+5
(620 ÷ 664)
Filter type
PORTS TYPE
Nominal
size
Gas NPT SAE
BSPP ODT
HF 620-20
HF 625-20
3/4" GE NE OD
HF 620-30
HF 625-30
1" 1/4 GG NG OG
HF 620-40
HF 620-50
1" 1/2 GH NH OH
HF 620 / HF 625
ICAT008-003 002 23
01/03.2011
IN / OUT PORTS
NPT THREAD
NPT
NPT thread (60°) in accordance with ANSI - ASME B1-20
CODE
Nominal
size
A
Æ B
C
mm (in) mm (in) Nm (lbf in)
NE
3/4" 3/4 NPT
23,5
(0.9251)
14
(0.5511)
25
+1
(221 ÷ 230)
NG
1" 1/4 1 1/4 NPT
38,5
(1.5157)
18
(0.7086)
50
+2,5
(442 ÷ 464)
NH
1" 1/2 1 1/2 NPT
44
(1.7322)
18,5
(0.7283)
70
+5
(620 ÷ 664)
SAE J514 THREAD
ODT
American thread UNC-UNF 60° in accordance with ANSI B 1.1
CODE
Nominal
size
A
Æ B
C
mm (in) mm (in) Nm (lbf in)
OD
3/4" 1 1/16" - 12 UNF - 2B
24,7
(0.9724)
20
(0.7873)
40
+2,5
(354 ÷ 376)
OG
1" 1/4 1 5/8" - 12 UNF - 2B
39,1
(1.5393)
20
(0.7873)
70
+5
(620 ÷ 664)
OH
1" 1/2 1 7/8" - 12 UNF - 2B
45,3
(1.7834)
20
(0.7873)
100
+5
(885 ÷ 929)
HF 620 / HF 625
24 002 ICAT008-004
ASSEMBLY AND REPLACING ELEMENT INSTRUCTIONS
01/03.2011
MOUNTING
Once you have checked the integrity of the filter inside its
package, proceed as follow:
A Take off the protection cap from the in/out ports.
B Secure the filter in the head through the holes of the upper
side (pos.2) tightening them as follows:
HF 620-20/30 and HF 625-20/30 = 44 lbf in (5 Nm)
HF 620-40 and HF 620-50 = 62 lbf in (7 Nm)
C Connect circuit's pipes to inlet and outlet ports using the
tightening torque indicated on pages 22 and 23.
D If the filter has a clogging indicator (pos.3 - 4 - 5 - 6 - 7 - 8), take
the protection cap off and screw the indicator in the dedicated
seat, then tighten to a tightening torque of 266 lbf in (30 Nm). If
the indicator is electric, complete the required connections.
E Start the circuit for a few minutes.
F Make sure there are no leaks.
REPLACING ELEMENT
Once the working hour limit indicated in the manteinance
instructions of the system is reached or when the clogging
indicators point out the limit pressure drop created inside the
filter, the element must be replaced. Pay attention to the
drainage of hydraulic oil, therefore prepare suitable containers to
collect it.
Proceed as follows:
A Stop the system in "machine stopped" status.
B Secure any shut-off valves on the hydraulic circuit.
C Remove the clogged element by hands-crewing it from the
filter head (pos.2) or if needed by using a strap wrench.
It is advisable not to recover the oil in the element since it is
full of clogging particles.
D Lubrificate the new element's seal (pos.1).
E Screw the new element until reaching the ledge with the
filter head (pos.2).
F After reaching the ledge, hand-screw the element for 3/4
more (for series 20) or 1/2 more (for series 30, 40 and 50).
G Re-open the eventual valves closed before.
H Start the machine for a few minutes.
I Make sure there are no leaks.
Pos. Description
1 Filtering element
2 Filter's head
3 Rear Manometer
4 Visual indicator
5 Electrical indicator
6 Differential visual indicator (series 20 and 30)
7 Differential visual indicator (series 40 and 50)
8 Differential electrical-visual indicator (series 40 and
50)
When ordering spare parts, always specify the reference number,
the filter code and quantity.
Example: Spare parts pos. 4 - HHE13051 - Q.ty 1
HF 620 / HF 625
ICAT008-005 002 25
01/03.2011
1
Filter type CODE
See table from pag. 12 to pag. 15
HF 620..
2
Filtering surface CODE
Standard
AS
3
Degree of filtration CODE
10 [mm] Micro-fibre glass
FG010
25 [mm] Micro-fibre glass
FG025
60 [mm] Steel wire mesh
MS060
90 [mm] Steel wire mesh
MS090
10 [mm] Cellulose
SP010
25 [mm] Cellulose
SP025
4
By-pass setting valve CODE
With By-pass setting valve 2.9 [psi] (0,2 [bar])
B02
With By-pass setting valve 25 [psi] (1,7 [bar])
B17
Without (Suction)
B0A
Without (Return)
B0R
5
Inlet port CODE
GAS threads (BSPP)
G3/4
GE
G11/4
GG
G11/2
GH
NPT threads
3/4
NE
11/4
NG
11/2
NH
SAE threads ODT
3/4
OD
11/4
OG
11/2
OH
6
Seals CODE
Buna
B
Viton
V
7
Indicators arranged CODE
Without
XN
Right on the head (1)(2)
XA
Left on the head (3)(4)
XB
Only for HF 620-40 (5)
XC
Only for HF 620-50 (5)
XD
8
Indicator's ports dimensions CODE
GAS Threads (BSPP)
G1/8
GA
G 1/8 with plug
DA
G 1/2 (only for HF 620-40 and HF 620-50)
GD
Holes in the wall for differential indicator
(only for HF 620-20 and HF 620-30)
FP
11
Indicators CODE
Without
G
Manometer - rear connection
M
Visual indicator
V
Electrical indicator
E
Diffential visual indicator
(only for HF 620-20 and HF 620-30)
D
Differential visual indicator
(only for HF 620-40 and HF 620-50)
H
Differential elctrical-visual indicator
(only for HF 620-40 and HF 620-50)
L
HOW TO ORDER A COMPLETE FILTER HF 620
12 3 456789
HF 620 - 20.135 - AS - FG010 - B17 - GE - B - XA - FP - D
Standard
On request
HF 620 / HF 625
26 002 ICAT008-005
01/03.2011
HOW TO ORDER A COMPLETE FILTER HF 625
1
Filter type CODE
See table from pag. 16 to pag. 17
HF 625..
2
Filtering surface CODE
Standard
AS
3
Degree of filtration CODE
10 [mm] Micro-fibre glass
FG010
25 [mm] Micro-fibre glass
FG025
60 [mm] Steel wire mesh
MS060
90 [mm] Steel wire mesh
MS090
10 [mm] Cellulose
SP010
25 [mm] Cellulose
SP025
4
By-pass setting valve CODE
With By-pass setting valve 25 [psi] (1,7 [bar])
B17
Without
B00
5
Inlet port CODE
GAS threads (BSPP)
G3/4
GE
G11/4
GG
G11/2
GH
NPT threads
3/4
NE
11/4
NG
11/2
NH
SAE threads ODT
3/4
OD
11/4
OG
11/2
OH
6
Seals CODE
Buna
B
Viton
V
7
Indicators arranged CODE
Without
XN
Right on the head (1)(2)
XA
Left on the head (3)(4)
XB
8
Indicator's ports dimensions CODE
GAS Threads (BSPP)
Holes in the wall for differential indicator
FP
11
Indicators CODE
Without
G
Diffential visual indicator
D
Standard
On request
12 3 456789
HF 625 - 20.135 - AS - FG010 - B17 - GE - B - XA - FP - D
HF 620 / HF 625
ICAT008-005 002 27
01/03.2011
HOW TO ORDER A REPLACEMENT ELEMENT
Standard
On request
1234
HE K45 - 20.135 - AS - FG010 - B
1
Element type CODE
See table pag. 18
HE K45..
See table pag. 19
HE K46..
2
Filtering surface CODICE
Standard
AS
3
Degree of filtration CODE
10 [mm] Micro-fibre glass
FG010
25 [mm] Micro-fibre glass
FG025
60 [mm] Steel wire mesh
MS060
90 [mm] Steel wire mesh
MS090
10 [mm] Cellulose
SP010
25 [mm] Cellulose
SP025
4
Seals CODE
Buna
B
Viton
V
HF 620 / HF 625
28 002 ICAT008-005
NOTES:
01/03.2011
Full range of filters
for all hydraulic circuits
Truck
Market
Material
Handling
Industrial
Building &
construction
Agriculture
Suction filters
Tank mounted
return line filters
In line filters Spin-On
In line medium and high
pressure filters
Accessories
HF 410
HF 412
HF 431
HF 434
HF 437
HF 502
HF 508
HF 620
HF 690
HF 705
HF 710
Filler breathers
Air filters
Level and temperature gauges
Pressure gauges
Clogging indicators
HF 547
HF 554
HF 570
HF 575
HF 578
HF 625
HF 650
HF 725
HF 735
HF 745
HF 760
HF 761
Pressure/vacuum gauges
HF 620 01 T A Edition: 01/03.2011
IKRON S.r.l.
Via Prampolini, 2 - 43044 Lemignano di Collecchio - Parma - Italy
Tel.: + 39 0521 304911 - Fax: + 39 0521 304900
Videoconferecing IP