LOGIC CARTRIDGE VALVE IN UNIQUE BODY
DIN 24342
1/3
L09b 03/16
Characteristics
TYPE
SIZE MAX PRESSURE AREA RATIO
ICLI-A16
DN 16
350 bar
1 : 1.1
1 : 1.5
1 : 1.5/S
ICLI-A25
DN 25
ICLI-A32
DN 32
ICLI-A40
DN 40
ICLI-A50
DN 50
1 : 1.1
1 : 2
Description
Two-way logic cartridges in unique body used to implement pressure, flow and direction controls.
Housing cavity dimensions DIN 24342 compliant.
1:1.1
section O : section C = 0.91
1:1.5
section O : section C = 0.67
1:1.5/S
section O : section = 0.67
E model STANDARD model
Models and symbols
LOGIC CARTRIDGE VALVE IN UNIQUE BODY
DIN 24342
2/3
L09b 03/16
Installation rules
The cartridges type ICLI-A** can be mounted in any position
Fluid to be used: hydraulic oil DIN 51524 compliant, viscosity between 30 and 100 mm
2
/s (cSt) at 40°C
Recommended filtration: 25µ
Hydraulic fluid temperature: from -20° to +75°C
Dimensions
TYPE ICLI-16 ICLI-25 ICLI-32 ICLI-40 ICLI-50
d
16 25 32 40 50
d1
22.5 27 38.5 54.4 62.5
D2
32 45 60 75 90
D3
25 34 45 55 68
H1
-
+0.1
0
43 58 70 87 100
H2
-
+0.1
0
56 72 85 105 122
H3
54 70 83 102 117
H4
0
-0.1
31 43.5 49 57 66
H5
20 30 30 30 35
H6
2 2.5 2.5 3 3
H7
2 2.5 2.5 3 3
T
0.03 0.03 0.03 0.05 0.05
T1
0.05 0.05 0.1 0.1 0.1
TYPE ICLI-16 ICLI-25 ICLI-32 ICLI-40 ICLI-50
A
65 85 102 125 140
B
46 58 70 85 100
C
2 4 6 7.5 8
D
48 62 76 92.5 108
E
12.5 13 18 19.5 20
F
M8x22 M12x30 M16x38 M20x46 M20x46
G
4 6 8 10 10
H
I
23 29 35 42.5 50
LOGIC CARTRIDGE VALVE IN UNIQUE BODY
DIN 24342
3/3
L09b 03/16
Ordering code
- - / /
Seals V = Viton Omit for NBR (standard)
A = 0.5 bar
E = (Only for 1:1,1) shutter orifice 0,8 (otherwise omit it) (others Ø on demand)
B =2 ba
r
C =4 ba
r
111 = 1:1,1 (16 - 25 - 32 - 40 - 50) 16 = DN 16
115 = 1:1,5 (16 - 25 - 32 - 40) 25 = DN 25
Area ratio 115/S =
1:1,5/S
(with dumping ) (16 - 25 - 32 - 40)
32 = DN 32
120 = 1:2,0 ( 50 ) 40 = DN 40
50 = DN 50
Logical cartridge valve in unique body
ICLI A** *** *
Opening pressure
Conventional size
**
Example:
ICLI-A25111-B =
DN 25 ; ratio 1:1.1; Spring 2 bar; Seal NBR
Diagrams