Shut off Valve, Sub-plate mounting, Model : MHSL
Ref. No : H04087, Release Oct 2006 (Dimensions in mm)
Construction Seat type.
Mounting type Sub-plate mounting type.
Interface Factory standard.
Flow direction From port `A' to port `B'.
Operating pressure 350 bar.
Hydraulic medium Mineral oil.
Viscosity range 10 cSt to 380 cSt.
Fluid temperature range -20
o
C to +70
o
C
Fluid cleanliness requirement As per ISO 19/16 or better.
Mass MHSL11-2.0 - 1.5 kg.
MHSL19-2.0 - 3.6 kg.
MHSL28-2.0 - 8.5 kg.
Maximum flow handling capacity Refer graph.
Copyrights
©
2006 hyloc hydrotechnic pvt. ltd. All rights reserved Engineering Datasheet, Page 1/2
Shut off valves model MHSL are rising spindle,seat type
valves with metal seat for leak-free closure between
it's port `A' & `B'.
The mounting interface conforms to Factory standard.
Bi-directional flow is possible in this model.
Description
Section
Hydraulic Symbol
Valve
Technical Specifications
AB
AB
H1 (max)
S2
S1
L
H2
H3
M
B
A
6
D
C
B
A
Model Code
A B C D H1 H2 H3 L S1 S2
M
Tightening Torque
MHSL11-2.0 47.8 65 60.5 78 106 35 79 64 27 27 M10x50L 16Nm
MHSL19-2.0 65.0 97 81.0 113 135 26 118 84 32 32 M16x50L 117Nm
MHSL28-2.0 92.0 127 92.0 127 186 60 131 120 50 50 M20x90L 238Nm
Valve
fixing screws