SELF-REVERSING VALVE
H D R - Intallation Data
5
HDR_EN_2025_01
These valves can be installed in any position without impairing
correct operation.
Ensure that there is no air in the hydraulic circuit.
Valves are fixed by means of screws or tie rods on a flat
surface with planarity and roughness equal to or better than
those indicated in the relative symbols. If minimum values are
not observed, fluid can easily leak between the valve and
support surface.
We recommend installing in the circuit as shown in the two
examples, connecting port A to the rear chamber of the
cylinder. In this way, the valve automatically positions itself so
that the rod retracts when the pump starts.
In order for the valve to operate corr
ectly, the ratio between
the cylinder areas must be between 1:1.25 and 1:2.
Use a HDR valve without the turning knob override.
The self-reversing function must be inactive when setting the
system pressure relief valve.
To do so, close the shut-off valve, start the pump, set the
pressure relief valve and stop the pump. Then, open the shut-
off valve and restart the pump.
Surface finishing
Use a HDR valve with the turning knob override (code K) .
The turning knob override allows you to set the pressure value
of the relief valve also in circuits with no shut-off valves.
The self-reversing function must be inactive when setting the
system pressure relief valve.
To do so, unscrew the set screw in the knob completely, then
tighten the knob up to the mechanical stop. The spool is now
clamped in P → B / A → T position.
Start the pump, set the relief valve and stop the pump.
Restore the initial working conditions of the valve by
unscrewing the knob almost completely. Screw the knob set
screw until its head is flush with the knob itself.
The valve is in initial working condition when the set screw
head is flush with the knob itself and the knob is completely
tightened.
CIRCUITS WITH SHUT-OFF VALVE
CIRCUITS WITHOUT SHUT-OFF VALVE
WARNING:
Do not use the manual override during operation: if you need
to stop the flow, switch off the pump.