TECHNICAL CATALOGUE
HDR
SELF-REVERSING VALVE
HDR3 350 bar 50 l/min
HDR5 320 bar 60 l/min
HDR_EN_2025_01
SELF-REVERSING VALVE
H D R - Technical Data
2
HDR_EN_2025_01
INTRODUCTION FLUIDS
OPERATING PARAMETERS HYDRAULIC SYMBOLS (TYPICAL)
The HDR valves are directional control valves hydraulic
actuated, with self-reversing spool with porting pattern
compliant to ISO 4401-03 and ISO 4401-05.
These valves reverse the flow dir
ection when the flowrate
stops in A or B line (f.e., when a cylinder reaches the end
stroke). The reversing process is independent of the working
lines pressure.
These valves are supplied with a zinc-nickel plating making
them the perfect choice for mobile and environmental
applications that require better protection.
Salt spray resistance up to 600 h (test according to UNI EN
ISO 9227 and UNI EN ISO 10289 tests and standards).
MAXIMUM
OPERATING
PRESSURE
HDR3 350 bar 5000 psi
HDR5 320 bar 4600 psi
FLOW RATE
HDR3 50 l/min 13.2 gpm
HDR5 60 l/min 15.9 gpm
MOUNTING
SURFACE
HDR3
ISO 4401-03-02-0-05
NFPA D03
HDR5
ISO 4401-05-04-0-05
NFPA D05
WEIGHT
HDR3 0.9 kg 2.0 lbs
HDR5 2.8 kg 6.2 lbs
RANGE
TEMPERATURES
ambient -20 to +54 °C - 4 to +130 °F
fluid -20 to +82 °C - 4 to +180 °F
FLUID VISCOSITY
range 10 - 400 cSt 60 -1900 SUS
recommended 25 cSt 120 SUS
FLUID
CONTAMINATION
ISO 4406:1999
class 20/18/15
Use mineral oil-based hydraulic fluids HL or HM type,
according to ISO 6743-4. For these fluids, use NBR seals.
For fluids HFDR type (phosphate esters) use FPM seals (code
V). For the use of other kinds of fluid such as HFA, HFB, HFC,
please consult our technical department.
Using fluids at temperatures higher than 80 °C (180 °F)
causes the accelerated degradation of seals as well as the
fluid physical and chemical properties.
From a safety standpoint, temperatures above 55 °C (130 °F)
are not recommended.
SELF-REVERSING VALVE
H D R - Model Number & Charachteristic Curves
3
HDR_EN_2025_01
FUNCTION
R
hydraulic actuated
self reversing spool
SEAL
N NBR (standard)
V Viton
VALVE SIZE
3 ISO 4401-03-02-0-05
5 ISO 4401-05-04-0-05
MANUAL OVERRIDE
0
no manual
override
K knob, turning
HDR -
- 2
design mark
CHARACTERISTIC CURVES - PRESSURE DROPS
Flow characteristic curves obtained with mineral oil with
viscosity of 36 cSt (170sus) at 50 °C (122 °F) and 24V DC
valve.
HDR3 HDR5
SELF-REVERSING VALVE
H D R - Installation Data
4
HDR_EN_2025_01
KNOB, TURNING (Code K)
KNOB, TURNING (Code K)
HDR3
HDR5
dimensions in mm [in]
dimensions in mm [in]
mounting
surface with
sealing rings:
4 OR 2037
90 shore A
Fastening bolts:
4 SHCS M5x30 - ISO 4762 - torque 5 Nm (A 8.8)
Threads of mounting holes: M5x10
Fastening bolts:
4 SHCS M6x40 - ISO 4762 - torque 8 Nm (A 8.8)
Threads of mounting holes: M6x10
mounting
surface with
sealing rings:
5 OR 2050
90 shore A
Allen key for set screw: 2,5 mm
Allen key for set screw: 3 mm
SELF-REVERSING VALVE
H D R - Intallation Data
5
HDR_EN_2025_01
These valves can be installed in any position without impairing
correct operation.
Ensure that there is no air in the hydraulic circuit.
Valves are fixed by means of screws or tie rods on a flat
surface with planarity and roughness equal to or better than
those indicated in the relative symbols. If minimum values are
not observed, fluid can easily leak between the valve and
support surface.
We recommend installing in the circuit as shown in the two
examples, connecting port A to the rear chamber of the
cylinder. In this way, the valve automatically positions itself so
that the rod retracts when the pump starts.
In order for the valve to operate corr
ectly, the ratio between
the cylinder areas must be between 1:1.25 and 1:2.
Use a HDR valve without the turning knob override.
The self-reversing function must be inactive when setting the
system pressure relief valve.
To do so, close the shut-off valve, start the pump, set the
pressure relief valve and stop the pump. Then, open the shut-
off valve and restart the pump.
Surface nishing
Use a HDR valve with the turning knob override (code K) .
The turning knob override allows you to set the pressure value
of the relief valve also in circuits with no shut-off valves.
The self-reversing function must be inactive when setting the
system pressure relief valve.
To do so, unscrew the set screw in the knob completely, then
tighten the knob up to the mechanical stop. The spool is now
clamped in P B / A T position.
Start the pump, set the relief valve and stop the pump.
Restore the initial working conditions of the valve by
unscrewing the knob almost completely. Screw the knob set
screw until its head is flush with the knob itself.
The valve is in initial working condition when the set screw
head is flush with the knob itself and the knob is completely
tightened.
CIRCUITS WITH SHUT-OFF VALVE
CIRCUITS WITHOUT SHUT-OFF VALVE
WARNING:
Do not use the manual override during operation: if you need
to stop the flow, switch off the pump.
Hydreco Hydraulics - Version Control Number: HDR_EN_2025_01
AUSTRALIA
AUSTRALIA
INDIA
HydrecoHydraulics Pty Ltd, Seven Hills (NSW)
HydrecoHydraulics Pty Ltd,Welshpool(WA)
HydrecoHydraulicsIndia Private Ltd, Bangalore
+61 2 9838 6800
+618 9377 2211
+91 80 67656300
sales-au@hydreco.com
reception-wa@hydreco.com
sales-in@hydreco.com
APAC
EMEA
GERMANY
ITALY
ITALY
ITALY
NORWAY
UK
Hydreco Hydraulics GmbH, Helmstedt (NI)
Hydreco HydraulicsIt
alia Srl, Vignola (MO)
Hydreco Hydraulics Italia Srl, Parma (PR)
Hydreco Srl, San Cesario S/P (MO)
Hydreco HydraulicsNorway AS, Nittedal
Hydreco HydraulicsLtd, Poole, Dorset
+49 535155860
+39 059 7700411
+39 0521 1830520
+39 059 330091
+47 22909410
+44 (0) 1202 627500
info@hydreco.de
sales-it@hydreco.com
sales-it@hydreco.com
cylinders@hydreco.com
post-no@hydreco.com
info-uk@hydreco.com
AMERICAS
NORTH/LATIN
HydrecoInc / Continental Hydraulics Inc, Shakopee (MN)
+1952 895 6400 sales@conthyd.com
Supported by a world w i d e network
www.h y d r eco.com
CONTACT INFORMATION
hydreco-hydraulics