Symbol
Description
The MP08-20X is a 2-way, manual pull to shift, spring return, screw-in, cartridge style directional
hydraulic valve
Operation
In the neutral position the MP08-20X valve blocks flow from port 2 to 1 until it is manually actuated
(pulled). When released the valve returns to its neutral position. The bias spring allows up to 180 psi
[12,4 bar] back pressure at port 1 before the valve will open
note: pressure at port 1 will directly act on the spring. Port 1 is intended to be a tank port only
Features
Hardened seat for long life and low leakage.
Remains closed to 12.4 bar (180 psi) back-pressure.
Compact, industry-common cavity.
Overview
Ratings
Pressure Ratings
Pressure rating
207 bar (3000 psi) - Note: Port 2
12.4 bar (180 psi) - Note: Port 1
Flow Ratings
Flow rating
See performance graph
Maximum internal leakage
0.25 ml/min (5 drops/min) - Note: Port 2 to 1 max at 207 bar (3000 psi)
Temperature Ratings
Operating fluid temperature
-40 to 100 °C (-40 to 212 °F) - Note: With buna N seals
-26 to 204 °C (-15 to 400 °F) - Note: With fluorocarbon seals
-54 to 107 °C (-65 to 225 °F) - Note: With polyurethane seals
Storage temperature
-40 to 70 °C (-40 to 160 °F)
Ambient temperature
-40 to 90 °C (-40 to 194 °F)
Other Ratings
Corrosion protection
960 hr salt spray per ASTM b117 (gmp08-20x)
Operating Parameters
Fluids
Mineral based or synthetic hydraulic fluid with lubricating properties
Fluid viscosity range
7.4 to 420 cSt
Maximum operating contamination level
20/18/14 per ISO 4406
Properties
Mechanical pull effort required
4.5 kg (10 lbf) - Note: Initial;
6.8 kg (15 lbf) - Note: At full travel
Unit weight
0.09 kg (0.19 lb) - Note: "t" option
0.10 kg (0.22 lb) - Note: "k" and "j" options
Internal wetted surface area
142 cm² (22 in²)
MP08-20
hydraforce.com
MANUAL CARTRIDGE VALVE NORMALLY CLOSED, 2-WAY
hydraforce.com
12/15/2020
MP08-20
Performance
Dimensions
Materials
Materials
Cartridge: Weight: 0.10 kg (0.22 lb); Steel with hardened work surfaces. Zinc-plated exposed surfaces; Buna N O-rings and back-ups
standard. Plastic knob optional.
Standard Ported Body: Weight: 0.16 kg (0.35 lb) Anodized high-strength 6061 T6 aluminum alloy, rated to 207 bar (3000 psi). Ductile
iron bodies available; dimensions may differ.
Installation Specifications
Cavity
VC08-2
Cartridge installation torque
25.8 to 28.5 N-m (19 to 21 ft-lb)
Orientation restriction
None
Accessories
Seal kit
SK08-2X-T - Note: X = seal option
Housings
MP08-20
hydraforce.com
MANUAL CARTRIDGE VALVE NORMALLY CLOSED, 2-WAY
hydraforce.com
12/15/2020
MP08-20
Order Code
POSITION CODE DESCRIPTION
MP08-20FG-H-J
F Adjustment
F D Black Plastic Knob with Lock Position Pin
F L Red Plastic Knob with Lock Position Pin
F R Threaded Shaft with Lock Position Pin
F T Threaded Shaft with Spring Return
G Screen
G BLANK NONE
G S 100 Mesh Screen
H Line Body
H 6T Aluminum SAE 6
H 8T Aluminum SAE 8
H 6TD Ductile Iron SAE 6
H 8TD Ductile Iron SAE 8
H 2B Aluminum BSPP 1/4" (2)
H 3B Aluminum BSPP 3/8" (3)
J Seal
J N Buna-N
J V Fluorocarbon
J P Polyurethane
J U PPDI Urethane
MP08-20
hydraforce.com
MANUAL CARTRIDGE VALVE NORMALLY CLOSED, 2-WAY
hydraforce.com
12/15/2020
MP08-20