Symbol
Description
EC56-42 is a screw-in, cartridge style, priority on demand pressure compensator valve with static load
sense. Intended to provide priority flow in required amount, while allowing excessive flow to be used for
auxiliary functions
Operation
With inlet flow at port 3, the EC56-42 will deliver required priority flow at port 4 regardless of load
pressure. Excessive flow exits at port 2 and port 1 is the load sense port. All ports may be fully
pressurized
Features
High pressure.
Priority-on-demand
Static load-sense.
Hardened parts for long life.
Quiet, modulated response.
Industry common cavity.
Optional corrosion-resistant plating for 960-hour salt spray per ASTM B117.
Overview
Ratings
Pressure Ratings
Pressure rating
345 bar (5000 psi)
Proof pressure
690 bar (10000 psi)
Burst pressure
1275 bar (18500 psi)
Flow Ratings
Inlet flow rating
115 lpm (30.0 gpm) - Note: Maximum, with compensating spring 5.5 bar (80 psi)
150 lpm (40.0 gpm) - Note: Maximum, with compensating spring 10.3 bar (150 psi)
189 lpm (50.0 gpm) - Note: Maximum, with compensating spring 15.2 bar (220 psi)
Priority flow rating
- Note: 80% of input flow when priority pressure exceeds bypass pressure. 50% of input
flow when bypass pressure exceeds priority pressure
Temperature Ratings
Operating fluid temperature
-40 to 100 °C (-40 to 212 °F) - Note: With buna N seals
-26 to 204 °C (-15 to 400 °F) - Note: With fluorocarbon seals
-54 to 107 °C (-65 to 225 °F) - Note: With polyurethane seals
-54 to 107 °C (-65 to 225 °F) - Note: With urethane seals
Storage temperature
-40 to 70 °C (-40 to 160 °F)
Ambient temperature
-40 to 70 °C (-40 to 160 °F)
Operating Parameters
Fluids
Mineral based or synthetic hydraulic fluid with lubricating properties
Fluid viscosity range
7.4 to 420 cSt
Maximum operating contamination level
18/16/13 per ISO 4406
Properties
Unit weight
0.67 kg (1.48 lb)
Internal wetted surface area
425 cm² (65.9 in²)
EC56-42
hydraforce.com
PRIORITY ON DEMAND PRESSURE COMPENSATOR WITH STATIC LOAD SENSE
hydraforce.com
1/21/2021
EC56-42
Performance
Dimensions
Materials
Materials
Cartridge: Weight: 0.74 kg (1.64 lb) Steel with hardened work surfaces. Zinc-plated exposed surfaces. Polyurethane or urethane seals
recommended for high pressure operation.
Ductile Iron Ported Body: Weight: 3.76 kg (8.3 lbs) Ductile iron (code "D") standard, rated to 345 bar (5000 psi).
Aluminum Ported Body: Weight: 1.39 kg (3.07 lb) Anodized, high-strength aluminum bodies rated for 207 bar (3000 psi) also available,
dimensions may differ.
EC56-42
hydraforce.com
PRIORITY ON DEMAND PRESSURE COMPENSATOR WITH STATIC LOAD SENSE
hydraforce.com
1/21/2021
EC56-42
Installation Specifications
Cavity
VC16-4
Cartridge installation torque
133 to 138 N-m (98 to 102 ft-lb)
Orientation restriction
None
Accessories
Seal kit
SK16-4X-MMM - Note: X = seal option
SK10-4U-0 - Note: Urethane
Housings
Order Code
POSITION CODE DESCRIPTION
EC56-42-H-J-R
H Line Body
H 0 No Body
H 12TD Ductile Iron SAE 12
H 16TD Ductile Iron SAE 16
J Seal
J N Buna-N
J V Fluorocarbon
J P Polyurethane
R Compensator Spring
R 80 80 Compensator Spring
R 150 150 Compensator Spring
EC56-42
hydraforce.com
PRIORITY ON DEMAND PRESSURE COMPENSATOR WITH STATIC LOAD SENSE
hydraforce.com
1/21/2021
EC56-42