PD12-S62
hydraforce.com
PILOTED DIRECTIONAL VALVE
Overview
Symbol
Description
The PD12-S62 is a screw-in, cartridge style, pilot operated, spool-type,
normally closed, hydraulic directional valve
Operation
In the neutral position flow is allowed between ports 2 and 3 and
between ports 4 and 5 bidirectionally. On remote pilot signal at port 1 the
valve's spool shifts to block flow at all ports, the spring chamber is
vented to the tank through port 6. The vented spring chamber allows the
valve to be fully pressurized at ports 1, 2, 3, 4, and 5 without affecting
required pilot pressure. Pressure at port 6 will affect required pilot
pressure
Features
Hardened spool and cage for long life.
Optional sealed spool between ports 1 and 2.
Choice of two bias spring values.
Vented spring chamber.
Ratings
Pressure Ratings
Pressure rating
241 bar (3500 psi)
Flow Ratings
Maximum inlet flow
57 lpm (15 gpm) - Note: In any combination of flows between ports 2 and 3 and ports 4 and
5 (e.g. 3 + 12 gpm, 7 + 8 gpm, 10 + 5 gpm, etc
Maximum internal leakage
246 ml/min (15 in³/min) - Note: At 207 bar (3000 bar)
Temperature Ratings
Maximum operating fluid
temperature
-40 to 100 °C (-40 to 212 °F) - Note: With buna N seals
-26 to 204 °C (-15 to 400 °F) - Note: With fluorocarbon seals
-54 to 107 °C (-65 to 225 °F) - Note: With polyurethane seals
Storage temperature
-40 to 70 °C (-40 to 160 °F)
Ambient temperature
-40 to 90 °C (-40 to 194 °F)
hydraforce.com
10/7/2020
PD12-S62
PD12-S62
hydraforce.com
PILOTED DIRECTIONAL VALVE
Operating Parameters
Fluids
Mineral based or synthetic hydraulic fluid with lubricating properties
Fluid viscosity range
7.4 to 420 cSt
Maximum operating
contamination level
20/18/14 per ISO 4406
Properties
Cartridge weight
0.48 kg (1.06 lb)
Internal wetted surface area
373 cm²; (57.9 in²;)
Performance
Dimensions
hydraforce.com
10/7/2020
PD12-S62
PD12-S62
hydraforce.com
PILOTED DIRECTIONAL VALVE
Materials
Materials
Cartridge: Weight: 0.48 kg. (1.06 lbs.) Steel with hardened work surfaces. Zinc-plated exposed surfaces. Buna N O-
rings and polyester elastomer back-ups standard.
Ported Body: Weight: 4.05 kg (8.93 lb.) H-series ductile iron standard. Rated to 345 bar (5000 psi).
Installation Specifications
Cavity
VC12-S6
Cartridge installation torque
44.7 to 50.2 N-m (33 to 37 ft-lb)
Orientation restriction
None
hydraforce.com
10/7/2020
PD12-S62
PD12-S62
hydraforce.com
PILOTED DIRECTIONAL VALVE
Accessories
Seal kit
SK12-S6X-BMMM - Note: (x = seal option)
Housings
Order code
hydraforce.com
10/7/2020
PD12-S62