Symbol
Description
The HSPEC10-34X is a high pressure, proportional solenoid-operated, poppet type, restrictive type,
pressure compensated, normally closed flow control, screw-in hydraulic cartridge valve with built-in
damping and load holding features.
Operation
With inlet at port 3 the valve will regulate flow out of port 2 regardless of load pressure with flow rate
proportional to current applied to the solenoid. Port 1 must be connected to port 3 to provide load
sense function for the compensator. When de-energized, the valve blocks flow from port 3 to port 2
while allowing free flow in opposite direction.
Note: Do not use an orifice disc wth this product.
Features
Industry-common cavity.
Continuous-duty rated coils.
Reduced manifold space claim.
Efficient wet-armature construction.
Optional waterproof E-Coils rated up to IP69K.
Patented high-strength solenoid tube
All HyPerformanceâ„¢ valves are tested to the rigorous standards of NFPA specification T2.6.1 and
are tested at a verification level of 90% and an assurance of 99%
Overview
Ratings
Pressure Ratings
Pressure rating
350 bar (5075 psi)
420 bar (6090 psi) - Note: 10% cycle life
Proof pressure
690 bar (10000 psi)
Burst pressure
1380 bar (20000 psi)
Flow Ratings
Flow rating
34 lpm (9 gpm)
Maximum internal leakage
7 drops/min - Note: With 350 bar (5075 psi) at port 3
Hysteresis
5.7 lpm (1.50 gpm) - Note: Maximum
Temperature Ratings
Operating fluid temperature
-40 to 100 °C (-40 to 212 °F) - Note: With buna N seals
-26 to 204 °C (-15 to 400 °F) - Note: With fluorocarbon seals
-54 to 107 °C (-65 to 225 °F) - Note: With urethane seals
Storage temperature
-40 to 70 °C (-40 to 160 °F)
Ambient temperature
-40 to 70 °C (-40 to 160 °F)
Operating Parameters
Fluids
Mineral based or synthetic hydraulic fluid with lubricating properties
Fluid viscosity range
7.4 to 420 cSt
Maximum operating contamination level
18/16/13 per ISO 4406
HSPEC10-34
hydraforce.com
SOLENOID PROPORTIONAL FLOW CONTROL VALVE, POPPET, NORMALLY CLOSED,
PRESSURE COMPENSATED
hydraforce.com
27FEB2022 16:46
HSPEC10-34
Properties
Unit weight
0.19 kg (0.43 lb) - Note: HSPEC10-34 without coil and nut
0.20 kg (0.45 lb) - Note: HSPEC10-34T without coil and nut
Internal wetted surface area
186.8 cm² (28.95 in²) - Note: HSPEC10-34
191.2 cm² (29.64 in²) - Note: HSPEC10-34T
Electrical Parameters
Note
With size 10 E-series coil
Maximum control current
1300 mA - Note: Coil 12 V
650 mA - Note: Coil 24 V
Threshold current
300 to 500 mA - Note: 12 V coil
150 to 250 mA - Note: 24 V coil
Dither PWM frequency
100 to 200 Hz
Performance
HSPEC10-34
hydraforce.com
SOLENOID PROPORTIONAL FLOW CONTROL VALVE, POPPET, NORMALLY CLOSED,
PRESSURE COMPENSATED
hydraforce.com
27FEB2022 16:46
HSPEC10-34
Dimensions
Installation Specifications
Cavity
HVC10-3
Cartridge installation torque
102 to 115 N-m (75 to 85 ft-lb) - Note: Steel/ductile iron cavity
81 to 88 N-m (60 to 65 ft-lb) - Note: Aluminum cavity
Coil nut torque
7 to 10 N-m (5 to 7 ft-lb)
Orientation restriction
None
Accessories
Seal kit
HSK10-3N-TB - Note: Buna N
SK10-3V-TB - Note: Fluorocarbon
SK10-3U-OO - Note: Urethane
Housings
Coils
Order Code
HSPEC10-34
hydraforce.com
SOLENOID PROPORTIONAL FLOW CONTROL VALVE, POPPET, NORMALLY CLOSED,
PRESSURE COMPENSATED
hydraforce.com
27FEB2022 16:46
HSPEC10-34
POSITION CODE DESCRIPTION
HSPEC10-34E-H-J-L
E Manual Override
E BLANK NONE
E T Variable Position Override, Red Knurled Knob
H Line Body
H 0 No Body
H 8HT Ductile iron SAE 8
J Seal
J N Buna-N
J V Fluorocarbon
J U PPDI Urethane
L Coil
L 0 No Coil
L 10EL 10 VDC, E-Coil, Dual Lead Wires
L 10ER 10 VDC, E-Coil, Deutsch
L 12EG 12 VDC, E-Coil, DIN 43650
L 12EJ 12 VDC, E-Coil, AMP Jr.
L 12EL 12 VDC, E-Coil, Dual Lead Wires, 18 inches long
L 12EL/36 12 VDC, E-Coil, Dual Lead Wires, 36 inches long
L 12ER 12 VDC, E-Coil, Deutsch
L 12EY 12 VDC, E-Coil, Metri-Pack 150
L 20ER 20 VDC, E-Coil, Deutsch
L 24EG 24 VDC, E-Coil, DIN 43650
L 24EJ 24 VDC, E-Coil, AMP Jr.
L 24EL 24 VDC, E-Coil, Dual Lead Wires, 18 inches long
HSPEC10-34
hydraforce.com
SOLENOID PROPORTIONAL FLOW CONTROL VALVE, POPPET, NORMALLY CLOSED,
PRESSURE COMPENSATED
hydraforce.com
27FEB2022 16:46
HSPEC10-34
L 24EL/36 24 VDC, E-Coil, Dual Lead Wires, 36 inches long
L 24ER 24 VDC, E-Coil, Deutsch
L 24EY 24 VDC, E-Coil, Metri-Pack 150
POSITION CODE DESCRIPTION
HSPEC10-34
hydraforce.com
SOLENOID PROPORTIONAL FLOW CONTROL VALVE, POPPET, NORMALLY CLOSED,
PRESSURE COMPENSATED
hydraforce.com
27FEB2022 16:46
HSPEC10-34