DIRECTIONAL VALVES
MV06-20 Manual Release Valve
DESCRIPTION
A thumb or cam-operated, screw-in, cartridge-style, two-way, normally-closed poppet-
type directional valve.
OPERATION
The MV06-20 blocks flow in the 2 to 1 flow path until a force applied by a cam is suffi-
cient to overcome a cumulative force from a bias spring and pressure. When the valve
is in a closed state, the ratio of areas between ports 1 and 2 is 30:1.
FEATURES
• Hardened seat and poppet for long life.
• Stainless steel cam button.
RATINGS
Operating Pressure: 241 bar (3500 psi)
Proof Pressure: 690 bar (10000 psi)
Burst Pressure: 1380 bar (20000 psi)
Flow Rating: 15 lpm (4 gpm)
Internal Leakage: 5 drops/minute (0.25 ml/min.) at 3500 psi (241 bar)
Required Thumb or Cam Force for Operation with Port 2 Loaded:
No load: 3.6 kg. (8 lb.)
69 bar (1000 psi): 7.3 kg. (16 lb.)
138 bar (2000 psi): 9.1 kg. (20 lb.)
241 bar (3500 psi): 11.4 kg. (25 lb.)
Temperature: -40 to 100°C (-40 to 212°F) with Buna N seals;
-15 to 400°C (-26 to 204°F) with fluorocarbon seals;
-54 to 107°C (-65 to 225°F) with polyurethane seals
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No orientation restrictions. See page 9.020.1.
Cavity: VC06-2, Cavity Variation “A”; See page 9.106.1
Cavity Tool: CT06-2; See page 8.600.1
Seal Kit: SK06-2X-T; See page 8.650.1
ISO SYMBOL
4.598.1
PERFORMANCE (Cartridge Only)
13.8/200
10.3/150
6.9/100
3.4/50
3.8
1
7.5
2
11.4
3
FLOW lpm/gpm
PRESSURE DROP vs. FLOW
2 to 1 Fully Open
32 cSt/150 sus oil at 40°C (104°F)
15.1
4
HYDRAFORCE
.com
®