TS90-G34 Proportional Pressure Reducing/Relieving
2.888.1
ELECTRO-PROPORTIONAL VALVES—PRESSURE CONTROLS
DESCRIPTION
A pilot-operated, spool-type, proportional pressure reducing/relieving valve. It is a
third-generation HydraForce drop-in, flange-mounted, cartridge-type valve. The coil is
an integral part of the valve and is not serviceable. The regulated pressure is propor-
tional to the input electrical current in the pressure ranges shown.
OPERATION
Without applied current, the TS90-G34 allows free flow from 3 to 4. When the coil is
energized, in reducing mode, flow is allowed from port 2 to 3. When the coil is ener-
gized, in relieving mode, flow is allowed from port 3 to 4.
FEATURES
• Economical drop-in style.
• Optional 233 micron mesh screen.
• Optional lock-down flange.
• Choice of several regulated pressure ratings.
• Several push-on termination options.
• Integral waterproof coil standard, IP69K, 1000-hour salt spray per ASTM B117.
RATINGS
Pressure Rating: 34.5 bar (500 psi)
Proof Pressure: Port 2 and 3: 241 bar (3500 psi); Port 4: 54 bar (780 psi)
Burst Pressure: 310 bar (4500 psi) ports 2 and 3 pressurized; 269 bar (3900 psi)
port 4 pressurized
Flow Rating: 38 lpm (10 gpm)
Maximum Internal Leakage: De-energized:
A: 0.40 lpm (0.11 gpm) at 15 bar (210 psi) inlet
B: 0.55 lpm (0.15 gpm) at 21 bar (305 psi) inlet
C: 0.60 lpm (0.16 gpm) at 31 bar (450 psi) inlet
Cycle Life: 10 million cycles
Operating Fluid Temperature: -40 to 149 °C (-40 to 300 °F) with HBNR seals;
-26 to 204 °C (-15 to 400 °F) with fluorocarbon seals.
Maximum Control Current: 1.08 A (10V); 0.88 A (12V); 0.74 A (14V); 0.54 A (20V);
0.44 A (24V); 0.37A (28V)
Control Pressure at Maximum Control Current: A: 14 bar (203 psi); B: 20 bar
(290 psi); C: 30 bar (435 psi)
Hysteresis: (150 Hz PWM) 4%
Resistance: 4.83 ohms (10V); 7.28 ohms (12V); 10.05 ohms (14V); 18.35 ohms
(20V); 29.54 ohms (24V); 40.36 ohms (28V)
Inductance: 58 mH (10V); 88 mH (12V); 127 mH (14V); 235 mH (20V); 357 mH
(24V); 537 mH (28V)
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: Flange-mounted. Mounting screws sold separately. Optional lockdown
flange also available; See page 8.525.1
Cavity: VC-G025; See page 9.111.1 Seal Kit: SK-G025; See page 8.650.1
ISO SYMBOL
PERFORMANCE
FLOW (gpm/lpm)
PRESSURE (bar)
Pressure Drop vs. Flow Characteristic
- - - - For Flow 3 to 4
—— For Flow 2 to 3
0
0
20/1.4
40/2.8
60/4.1
80/5.5
100/6.9
2
8
4
15
8
30
6
23
10
38
120/8/3
0
50/3.4
100/6.9
150/10.3
250/17.2
% of Maximum Control Current
Note: Inlet pressure set to 14.5 psi (1 bar)
above maximum control pressure.
02010 30 50 70 9040 60 80 100
Reducing Pressure vs. Current Characteristic
Inlet Pressure at Port 2 , Control Pressure at Port 3
Control Current: 150 Hz PWM
200/13.8
300/20.7
350/24.1
400/27.8
450/31.0
A
B
A
2
HYDRAFORCE
.com
®
PRESSURE (psi/bar)
0
50/3.4
100/6.9
150/10.3
250/17.2
TIME (seconds)
2.96 2.98 3.00 3.02 3.04 3.06
Typical Step Response Curve - Off Time
Data Shown for TS90-G34B with 12V Coil
21 bar (305 psi) Inlet Pressure
DC Current, Regulated Port Blocked
200/13.8
300/20.7
350/24.1
1.00
0.50
CURRENTCURRENT
PRESSURE
PRESSURE (psi/bar)
0
50/3.4
100/6.9
150/10.3
250/17.2
TIME (seconds)
1.00 1.02 1.04 1.06 1.08
1.10
Typical Step Response Curve - On Time
Data Shown for TS90-G34B with 12V Coil
21 bar (305 psi) Inlet Pressure
DC Current, Regulated Port Blocked
200/13.8
300/20.7
350/24.1
1.00
0.50
CURRENT