DESCRIPTION
A high pressure, proportional, solenoid-operated, 3-way, normally-closed, flow
control, screw-in hydraulic cartridge valve intended for post-compensated applications
with load-sense systems. In post-compensated systems, the load-sense port 1 of the
HSPEC12-30A valve is connected to the highest load, which maintains flow sharing
when flow demand exceeds flow supply. Pressure compensation value of the valve
defined as pressure difference between inlet and load sense ports is provided by
appropriate setup of a pump load sense control or by additional pressure compensa-
tor valve, one for the whole system, in case the pump is non-adjustable.
OPERATION
When de-energized, the HSPEC12-30A blocks flow from port 3 to port 2. The valve
will regulate flow out of port 2 regardless of load pressure with flow rate proportional to
current applied to the solenoid.
FEATURES
• Integral post-compensator. • Uses "A" type linear metering poppet.
• Integral load sense. • Manual override option.
• Reduced manifold space claim. • E-Coils rated up to IP69K.
• Continuous-duty rated coils. • Flow sharing possible.
• All HyPerformance™ valves are tested to the rigorous standards of NFPA specifica-
tion T2.6.1 and are tested at a verfication level of 90% and an assurance of 99%.
RATINGS
Operating Pressure: 350 bar (5075 psi); 10% cycle life; 420 bar (6090 psi)
Note: All HyPerformance™ products are tested for 900K cycles at 350 bar and
100K at 420 bar.
Proof Pressure: 690 bar (10000 psi)
Burst Pressure: 1380 bar (20000 psi)
Flow Rating: 68 lpm (18 gpm) at 150 psi (10.3 bar) compensation value
Internal Leakage: Port 3 to port 2 or port 1 to port 2: 7 drops/minute with 350 bar
(5075 psi) at port 3 or port 1.
Operating Temperature: -54° to 107°C (-65° to 225° F) with urethane seals
Installation: No restrictions; See page 9.020.1
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Cavity: HVC12-3; See page 9.112.1
Cavity Tool: HCT12-3; See page 8.600.1
Seal Kit: HSK12-3U-0; See page 8.650.1
HSPEC12-30A Proportional Flow Control Valve
ISO SYMBOL
2.319.1
PERFORMANCE (Cartridge Only)
HYDRAFORCE
.com
®
ELECTRO-PROPORTIONAL VALVES - FLOW CONTROL
PRESSURE DROP vs. FLOW
Port 3 to 2, 12V Coil, 100 Hz PWM
10.3 bar (150 psi) Compensation Value
32 cSt/150 sus oil at 40°C (104°F)
17.2/250
10.3/150
3.4/50
6.9/100
13.8/200
FLOW lpm/gpm
0 19
5.0
38
10.0
57
15.0
76
20.0
95
25.0
20.7/300
FLOW VS. CURRENT
10.3 bar (150 psi) Compensation Value
310 bar (4500 psi) Load at Port 2
12V Coil, 100 Hz PWM
75.7/20
68.1/18
37.8/10
22.7/6
CURRENT mA
FLOW lpm/gpm
0 200 400 600 800 1000 1200
1400
60.6/16
53.0/14
45.5/12
30.3/8
15.1/4
7.6/2