HSV12-29 HyPerformance™ Poppet, 2-Way,
DESCRIPTION
A solenoid-operated, 2-way, piloted, poppet-type, normally open, bi-directional, screw-
in hydraulic cartridge valve, designed to function as a load holding or blocking valve in
high-pressure applications requiring low internal leakage bi-directionally.
OPERATION
When de-energized, the HSV12-29 allows flow in both directions. When energized, the
valve blocks flow in both directions.
Operation of Manual Override Option: The manual override feature is intended for
emergency use, not continuous duty operation. To shift the valve manually, push and
hold down the manual override button or knob.
FEATURES
Bi-directional operation.
Continuous-duty rated solenoid.
Hardened seat for long life and low leakage.
Optional coil voltages and terminations.
Efficient wet-armature construction.
Cartridges are voltage interchangeable.
Manual override option.
Waterproof E-Coils rated up to IP69K.
• Corrosion-resistant plating.
Unitized, molded coil design.
Cost effective cavity.
All HyPerformance products are tested to the rigorous standards
of the NFPA specification T2.6.1.
All HyPerformance valves are tested at a verification level of 90%
and an assurance of 99%.
RATINGS
Operating Pressure: 350bar (5075psi); 10% cycle life: 420bar (6090psi)
Note: All HyPerformance products are tested for 900K cycles at 350bar and 100K
cycles at 420bar.
Proof Pressure: 690bar (10,000psi)
Burst Pressure: 1380bar (20,000psi)
Flow Rating: 114 lpm (30 gpm)
Internal Leakage: 7 drops/minute with 350bar (5075psi) at port 2.
Temperature: -54 to 107°C (-65 to 225°F) with urethane seals
Coil Duty Rating: Continuous from 85% to 115% of nominal voltage
Initial Coil Current Draw at 20°C: E-Coil: 1.7 amps at 12Vdc; 0.85 amps at
24Vdc
Minimum Pull-in Voltage: 85% of nominal at 350bar (5075psi)
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: HVC12-2; See page 9.112.1
Cavity Tool: HCT12-2XX; See page 8.600.1
Seal Kit: SK12-2U-0; See page 8.650.1
Coil Nut: Part No: 4553800
1.099.3
11.0/160
8.3/120
5.5/80
2.8/40
37.9
10
75.8
20
113.6
30
FLOW lpm/gpm
PRESSURE DROP bar/psi
Pressure Drop vs. Flow
(Cartridge only)
2 to 1 —— 1 to 2 - - - -
32 cSt/150 sus oil at 40°C (104°F)
ISO SYMBOL
PERFORMANCE
(Cartridge Only)
SOLENOID VALVES
HYDRAFORCE
.com
®
Blue rectangles are links to other catalog pages.
HSV12-29
DIMENSIONS
MATERIALS
Cartridge: Weight: (without coil and
nut) 0.29kg (0.63lb) Steel with
hardened work surfaces. Urethane
seals without back-up rings
standard.
Standard Ported Body: Weight:
2.62kg (1.18lb) H-series ductile
iron. Rated to 350bar (5075psi).
See page 8.012.1.
10-Size E-Coil: Weight: 0.41kg
(0.9lb); Fully encapsulated with
rugged external metal shell.
Rated up to IP69K with integral
connectors. See page 3.400.1.
1.099.4
COIL MUST BE
INSTALLED WITH
LETTERING UP
ORIFICE DISC CANNOT
BE USED WITH THIS PRODUCT
due to HyPerformance
TM
Cavity.
1.31
ACROSS FLATS
33.3
0.34 (8.7 mm)
Dia. Mounting
Holes (2)
**TORQUE:
135 – 145 ft-lb.
(183 – 197 Nm)
0.75
19.1
ACROSS FLATS
TORQUE: 5 – 7 ft-lb
(6.8 – 9.5 Nm)
3.25
82.6
1.33
33.7
1.06
27.0
2.25
57.2
2.56
65.0
3.50
88.9
0.35
8.8
0.34 TYP
8.7
2.50
63.5
1.83
46.5
3.02
76.6
3.96
100.7
DUCTILE IRON
BODY SHOWN
MANUAL OVERRIDE
OPTION ‘K’
4.02
102.1
MANUAL OVERRIDE
OPTION ‘P’
TO ORDER
HSV12-29__ - __ __ __ __ - __ - __ __ __ __ __
Option
None
(Blank)
Manual Override K
Manual Override P
Seals
Urethane U
Voltage
0 Less Coil**
12 12Vdc
24 24Vdc
®
HYDRAFORCE
HYDRAFORCE
.com
®
Urethane seals recommended for
pressures over 241bar (3500psi).
Consult factory for additional seal
options.
**Includes E-Coil Nut.
For Coils with Zener Diode, add /Z to option code.
For example: ER/Z. Not available on all models.
See coil option info. on page 3.400.1
Coil Termination
Deutsch DT04-2P ER (IP69K)
Metri-Pak 150 EY (IP69K)
Dual Lead Wires EL (IP69K)
Amp Jr. Timer EJ (IP67)
DIN 43650 EG (IP65)
Normally Open, Bi-directional
Porting
Cartridge Only
0
SAE 12 12HT
**Cartridge torque shown for ductile iron manifold. Torque 60-65 ft-lb (81-88 Nm) in aluminum.
Aluminum housing is rated to 207bar (3000psi).
For Manual Override options
see page 1.001.1