Series E Environmental Coils
NEW SERIES E WATER-PROOF / WEATHER-RESISTANT SOLENOID VALVE COILS
3.400.1
New Series E coils are the latest innovation in coil technology
from Hydraforce. They are designed to meet the demanding
requirements of mobile and industrial applications where
weather resistance is required. Models with Deutsch DT and
Metri-Pack
®
integral connectors and new dual leadwire models
meet or exceed all IP69K standards for weather resistance,
offering superior reliability under the most demanding condi-
tions. Series E coils have passed what is known in the
construction, agricultural and mobile equipment markets as
the “Thermal Shock Dunk Test.
IP69K Rated with Integral Connectors
and with New Dual Leadwires
Models with Deutsch DT and
Metri-Pack
®
connectors as well as the
new dual leadwire models are rated for
IP69K. DIN and dual spade connections
are rated for IP65. (See page 3.400.2 for
a description of ratings.)
Fully Encapsulated
Windings
Coils are fully encapsulated for
zero leak paths when ordered
with integral connector options.
High Temperature Operation
Class 200°C (392°F) rated magnet
wire and insulation materials per
NEMA Standard MW 1000 allow high
temperature operation and ensure
long life under demanding conditions.
Continuous-duty operation up to
100°C and 115% of nominal voltage.
Field Retrofit-able
In most cases, Series E
coils can be used to
replace existing coils
on HydraForce valves
already in operation.
Easy Installation
No O-rings, external sealing,
or waterproofing kits required.
Thermal Shock Dunk Test Rated
Series E coils with leadwires,
Deutsch DT and Metri-Pack
®
connectors have passed what
is known in the construction,
agricultural and mobile equipment
markets as the “Thermal Shock
Dunk Test. (See page 3.400.2
for a description of this test.)
Rugged Metal Shell
The rugged external metal shell
provides exceptional protection
against physical damage, ensuring
durability under harsh operating
conditions. It is salt spray rated for
1000 hours per ASTM B117
specifications.
NOTE: Some coils, including those manufactured prior to 1-1-04, may differ slightly in construction from this illustration. See page 3.400.17
COILS AND ELECTRONIC CONTROLS
Series E coils feature a new, fully encapsulated coil winding
technology. Deutsch and Metri-Pack
®
connectors are molded
into the coil encapsulation, assuring IP69K weather resistance.
An external metal shell serves as the element to concentrate
the magnetic flux for the coil winding and also functions as a
rugged container for the coil. No O-rings or waterproofing kits
are required.
Models are available to fit most HydraForce valves. In most
applications, these coils can be used to retrofit HydraForce
valves already in field operation and will offer superior
weather resistance.
New Series E Coil
design illustrated
Shock Resistant
Integral grommet for
Deutsch DT connectors
increases durability
under conditions of
high random shock.
HYDRAFORCE
.com
®
3.400.2
Series E Environmental Coils
IMPROVING DURABILITY TO ASSURE LONG LIFE IN THE HARSHEST ENVIRONMENTS
HydraForce has made design changes to the industry-leading
environmentally-hardened Series E coils. The new design
provides longer life under high-temperature conditions, as well
as easier and more convenient interchange with our Series D
standard-duty coils.
The Story Behind the Ratings
To appreciate the performance of the new Series E coils, it is
helpful to have a working knowledge of the testing conducted
to assure coil life in the harshest environments. Many OEMs
request a coil that is IP67 or IP69 rated. These ratings do not
address the issue of the effect of high temperatures on coil life
and operation. Therefore they are of limited value in evaluat-
ing the suitability of a coil for use in typical mobile equipment
applications.
Why temperature matters: When a coil is heated, the air
inside the coil expands, creating internal pressure, causing the
heated air to attempt to exit the coil. If the coil is then
submerged in cold water, the air within the coil cools and
contracts, drawing water into the coil through any seams or
voids in the coil encapsulant. Eventually the water will find its
way into the winding area, causing the coil winding to corrode
or short-circuit, resulting in coil failure.
IP ratings are international specifications for electrical equip-
ment which define various levels of protection against failure
resulting from contamination by water or other foreign sub-
stances. The IP67 rating is based on submerging the coil in
one meter of water for 30 minutes. The coil is then inspected
for evidence of water infiltration. The IP67 specification loosely
states that “ingress of water in quantities causing harmful effect
shall not occur.The exact meaning of the phrase “harmful
effect” is not precisely defined, and is therefore open to some
interpretation. In this test, the coil is not subjected to high tem-
peratures, so the effects of thermal stress are not
considered.
The IP69 rating, which is currently only part of the DIN version
of this specification, first requires that the coil pass the test for
IP67 as described above. Beyond that, the coil and its integral
electrical connector are subjected to a rigorous high-pressure
water spray. The water is mixed with detergent, is held at a tem-
perature of 80°C., and is sprayed at the coil from a distance of
100 mm (4 inches) at a pressure of 100 bar (1450 psi). Again,
the specification does not precisely define the amount of water
ingress that would be considered unacceptable.
HydraForce Ratings
Working with major mobile equipment OEMs, HydraForce
has developed even more rigorous tests that are designed to
assure that our coils will perform reliably under the harshest
real-world application conditions. Both our original and our
new Series E coils meet or exceed the requirements of what is
known as the “Thermal Shock Dunk Test.” In this test the coil is
thermally “soaked” for two hours in an ambient temperature of
100°C. The coil is then immersed immediately in a 0°C salt-
water bath for two hours. This procedure is repeated ten times.
The coil is then inspected for water ingress. By Hydraforces
standards, the coil is considered to have passed this test if
there is NO detectable water ingress, as determined by visual
inspection and a “high pot” test. This standard requires a totally
sealed coil that is impervious to moisture infiltration, even
under widely varying ambient thermal conditions.
The new Series E coils can now withstand at least 10
cycles of the “Thermal Shock Dunk Test.
In addition to the requirements of the industry-recognized,
“Thermal Shock Dunk Test,” described above, HydraForce
further tests these coils for durability against failure due to
vibration, as well as against failure due to the application of
voltage above the coil’s standard duty rating while it is simulta-
neously subjected to continually varying ambient temperatures.
Beyond enhancing the durability of the coils, we have
decreased the wattage by approximately 10%. This reduces
the power consumption and also allows the operating
temperature range to be extended. The new design also
improves the ease and convenience of interchanging these
coils with HydraForce’s Series D (standard duty) coils, the
original Series E coils, as well as the older “W-style waterproof
option. The new Series E coils use the same retaining nuts as
the Series D coils, simplifying interchangeability, inventory and
assembly requirements and procedures.
See page 3.400.17 for detailed information describing the
differences between the original Series E coils and the new
Series E coils, including part number cross-references for the
coils, the retaining nuts, and the spacers used on the dual-
solenoid valves.
®
HYDRAFORCE
HYDRAFORCE
.com
®
Series E Environmental Coils
OUR COIL TESTING PROGRAM IS THE MOST STRINGENT AND RIGOROUS IN THE INDUSTRY
3.400.3
COILS AND ELECTRONIC CONTROLS
1.) Extended Thermal Shock Immersion Test – IP67
Ref. Exceeds IP67 per standard EN60529
The purpose of this test is to try to induce cracks in the
encapsulation of the coil.
The coil is heated for two hours at an ambient temperature
of 105°C (±5°C), then immediately immersed in a solution
of water, detergent and salt at a temperature of 0° to 5°C for
two hours. The coils is then visually inspected for cracks and
water penetration. This process is repeated ten times.
2.) Salt Spray Test DIN 50 021 Level 1
(Ref: Standard ASTM B117)
This accelerated test is
designed to simulate the
corrosive environment that
the coil will encounter during
the life of the vehicle.
The coil is subjected to a
continuous salt spray as per
ASTN B117 for a period of 20
hours. The coil is then rinsed
and dried.
3.) Inorganic Dust Test
ANSI/ASAE EP455 Section 5.3
This tests for the effects of
dust on the coil.
The coil is placed in a dust
chamber containing the equiva-
lent of air cleaner fine dust.
Sufficient air movement is provid-
ed to maintain a minimum 0.88g
per cubic meter with the coil
positioned in its normal mounting
position. The test is
run for a minimum of 24 hours.
This accelerated test
simulates random vibration
that the coil will encounter
when used on heavy-duty
equipment.
Functional performance is
monitored under the following
vibration levels shown in the
table below for 72 hours in each
of the three perpendicular axes.
The coil is then checked for
impaired function, loose parts
and fatigue cracks induced by
the test.
4.) Vibration Test
Measured Accelerated
Frequency PSD Acceleration Test PSD
(Hz) (G 2/Hz) Factor (G 2/Hz)
20 0.422 x 2 0.844
25 0.781 x 2 1.562
76 0.174 x 2 0.348
137 0.00283 x 7.2 0.020374
216 0.00073 x 7.2 0.005256
261 0.00119 x 7.2 0.008568
320 0.00042 x 7.2 0.003024
399 0.0000415 x 7.2 0.000298
626 0.0000265 x 7.2 0.0001908
712 0.000452 x 7.2 0.0032544
799 0.0000491 x 7.2 0.00035352
966 0.00117 x 7.2 0.008424
1424 0.00000965 x 7.2 0.00006948
1597 0.00012 x 7.2 0.000864
1996 0.0000154 x 7.2 0.0001108
Vibration Test Profile:
HYDRAFORCE
.com
®
3.400.4
Series E Environmental Coils
COIL TESTING PROGRAM (contd)
5.) Operating Shock
This test simulates sudden,
severe shock induced when
the vehicle is driven over
rough terrain.
The coil must withstand a 5
ms pulse of 490 m/sec
2
(50 g).
Impaired function, loose parts,
and fatigue cracks caused by
this test result in part rejection.
The test is repeated a total of
five times in each of the three
perpendicular axes.
Coils may be subjected to
various chemicals throughout
their life. In this test a coil is
completely immersed in only
one each of the following fluids
for a period of 5 minutes. Twelve
coils are used at a time. After
immersion the coils are heated
for four hours at 50°C and the cycle is repeated for a total of
ten trials. Impaired function as a result of this test is cause for
failure.
• Gasoline • Diesel Fuel
• Engine Oil • Phosphate Wash
• Hydraulic Fluid • Degreaser
• Bearing Grease • Windshield Washer Fluid
• Antifreeze Battery Acid
• Fertilizer (28% Nitrogen
with ammonium nitrate
and urea at a pH of 5)
6.) Chemical Resistance
7.) Bench Handling Shock
This test simulates the effects
of dropping a coil while it is
being handled.
The coil is dropped from a
distance of 450mm (±5mm) onto
a solid oak bench top at least
44mm thick. The test is repeated
by dropping the coil once on all
practical edges and faces.
Impaired function as a result of
this test is cause for rejection.
8.) Storage Temperature
This test simulates the effects of storage in extreme
temperatures for some time.
While not in operation, the coil is subjected to +105°C and
then –55°C for 20 hours each. Impaired function as a result
of this test is cause for rejection.
9.) Humidity
This test simulates the effects
of relative humidity on the
coil.
The coil is soaked at 40°C
and 95% relative humidity for
168 hours each while the coil
is not in operation. Impaired
function as a result of this test
is cause for rejection.
®
HYDRAFORCE
HYDRAFORCE
.com
®
Series E Environmental Coils
3.400.5
COILS AND ELECTRONIC CONTROLS
COIL TESTING PROGRAM (contd)
10.) Continuous Immersion – IP68
Ref. Standard EN60529
In this test the coil is immersed while powered on.
The coil is immersed in 1 meter of water at an ambient
temperature of 25°C (±5°C) for 120 hours while powered
according to the chart below. Impaired function as a result
of this test is cause for rejection.
ON
120
110
90
130
140
20 22 24181614121084620
100
60
80
70
50
30
10
40
20
0
% of NOMINAL VOLTAGE
TIME (Hours)
TEST VOLTAGE
Percent of Nominal for 24-Hour Period
113% 113%
133% 133%
75%
ON – OFF
11.) Maximum Load Cycling
This accelerated test simulates temperature cycling
to induce cracks or separation between components
of the coil.
Coils are installed in an environmental chamber set to 85°C
and 133% of nominal voltage is applied for 1 hour. After
1 hour, the power is immediately switched off and back on
within 2 seconds. 133% of nominal voltage is then applied for
a period of 5 minutes. After 5 minutes, power is immediately
switched off and then back on within 2 seconds. This
5-minute cycle is repeated for a total of 168 hours (power is
turned off and on within 2 minutes every 5 minutes). Cracks
in the encapsulation, separation in components, or impaired
function are cause for rejection.
220% of
Nominal
Voltage
12.) Jump Start
This test simulates the voltage required to jump start
heavy equipment.
The coil is thermally soaked in an environmental chamber
at 70°C for 2 hours. It is then subjected to 220% of nominal
voltage for 5 minutes.
HYDRAFORCE
.com
®
3.400.6
Series E Environmental Coils
COIL TESTING PROGRAM (contd)
13.) High Pressure Cleaning – IP69K
Ref. Standard DIN 40 050, part 9
This test simulates high-
pressure steam-jet cleaning
of a component.
14.) Combined Operating Voltage, Humidity
and Temperature
This test simulates the combined effects of some of the
previous tests.
The coil is simultaneously subjected to the voltage, tempera-
ture and humidity profiles shown in the graphs below. The
cycle is repeated for a total of 600 hours (25 days). The coils
are inspected every 20 cycles for cracks in the encapsulation,
separation of components, or impaired function as a result of
this test. Any induced flaws will result in rejection.
ON – OFF
120
110
90
130
140
56
43120
100
60
80
70
50
30
10
40
20
0
% of NOMINAL VOLTAGE
TIME (Hours)
OPERATING VOLTAGE
Percent of Nominal for 6-Hour Period
133%
40
50
60
70
80
90
56
43120
10
30
20
0
-20
-40
-50
-10
-30
TEMPERATURE (C)
TIME (Hours)
OPERATING TEMPERATURE
70 ºC Max.
-40 ºC Min.
40
50
60
70
80
56
43120
10
30
20
0
% RELATIVE HUMIDITY
TIME (Hours)
OPERATING HUMIDITY
70%
25%
14.) Combined Operating Voltage, Humidity
and Temperature (continued)
®
HYDRAFORCE
HYDRAFORCE
.com
®
1.41
35.8
1.40
35.6
1.43
36.3
INCH
MILLIMETRE
1.43
36.3
DIA.
1.41
35.8
1.43
36.3
DIA.
2.92
74.2
2.92
74.2
INCH
MILLIMETRE
3.400.7
110
120
60 70 80 90 10050403020100-20 -10-30-40
100
80
90
70
60
50
% OF RATED VOLTAGE
AMBIENT TEMPERATURE (C)
CONTINUOUS DUTY OPERATING RANGE
Minimum Voltage Required for Pull-In; 32 cSt/150 sus oil at 40°C
Operating Range
Series E Environmental Coils
COILS AND ELECTRONIC CONTROLS
ER
IP69K Rated 08-Size Coil
Thermal Shock Dunk Test Rated Coil
Deutsch DT04-2P Connector
Mating Connector: Deutsch No. DT06-2S — HF Part No. 4001417
EY
IP69K Rated 08-Size Coil
Thermal Shock Dunk Test Rated Coil
Metri-Pack
®
150 Connector
Mating Connector: Delphi Packard No. 12052641; HF Part No. 6110119
HYDRAFORCE
.com
®
Dual Coil for SP08-47, SP08-57,
SP08-58, SV08-47, SV08-58 valves
Dual Coil for SP08-47, SP08-57,
SP08-58, SV08-47, SP08-58 valves
Note: Electrical specifications for Series E coils differ from those for standard
HydraForce coils. (Refer to page 3.200.1 for standard coil specifications.)
Coil
Weight
Operating
Voltage
10 VDC
12 VDC
20 VDC
24 VDC
Resistance
at 20°C
6.2 ohms
8.8 ohms
23.9 ohms
33.8 ohms
Initial
Current
Draw
1.6 amps
1.4 amps
0.8 amps
0.7 amps
Power
15.9 watts
17.2 watts
15.3 watts
16.6 watts
ER/Z*
Coil
Part No.
ER
Coil
Part No.
EY/Z*
Coil
Part No.
EY
Coil
Part No.
* Models with Zener Diode
4303610
4303612
4303620
4303624
4303810
4303812
4303824
4303410
4303412
4303420
4303424
4304010
4304012
4304020
4304024
136 g. (4.8 oz.)
136 g. (4.8 oz.)
136 g. (4.8 oz.)
136 g. (4.8 oz.)
08-SIZE SERIES E COILS (also for use on 98-size screw-in spool-type valves)
3.400.8
Series E Environmental Coils
08-SIZE SERIES E COILS (also for use on 98-size screw-in spool-type valves)
®
HYDRAFORCE
HYDRAFORCE
.com
®
110
120
60 70 80 90 10050403020100-20 -10-30-40
100
80
90
70
60
50
% OF RATED VOLTAGE
AMBIENT TEMPERATURE (C)
CONTINUOUS DUTY OPERATING RANGE
Minimum Voltage Required for Pull-In; 32 cSt/150 sus oil at 40°C
Operating Range
EL
IP69K Rated 08-Size Coil
Thermal Shock Dunk Test Rated Coil
1.41
35.8
1.50
38.1
1.43
36.3
INCH
MILLIMETRE
DIA.
2.92
74.2
Note: Electrical specifications for Series E coils differ from those for standard
HydraForce coils. (Refer to page 3.200.1 for standard coil specifications.)
Coil
Weight
Operating
Voltage
10 VDC
12 VDC
20 VDC
24 VDC
Resistance
at 20°C
6.2 ohms
8.8 ohms
23.9 ohms
33.8 ohms
Initial
Current
Draw
1.6 amps
1.4 amps
0.8 amps
0.7 amps
Power
15.9 watts
17.2 watts
15.3 watts
16.6 watts
EL/Z* Coil
18" Wire
Part No.
EL Coil
18" Wire
Part No.
EL Coil
36" Wire
Part No.
* Models with Zener Diode
4306812
4306824
4305110
4305112
4305120
4305124
4308710
4308712
4308724
136 g. (4.8 oz.)
136 g. (4.8 oz.)
136 g. (4.8 oz.)
136 g. (4.8 oz.)
Dual Coil for SP08-47, SP08-57,
SP08-58, SV08-47, SP08-58 valves
3.400.9
Series E Environmental Coils
COILS AND ELECTRONIC CONTROLS
08-SIZE SERIES E COILS (also for use on 98-size screw-in spool-type valves)
HYDRAFORCE
.com
®
EG
IP65 Rated 08-Size Coil; DIN 43650 Connector
IP67 rated if used with sealed mating connector and gasket
EJ
IP67 Rated 08-Size Coil
Amp Jr. Timer Connector
Note: Electrical specifications for Series E coils differ from those for standard
HydraForce coils. (Refer to page 3.200.1 for standard coil specifications.)
Coil
Weight
Operating
Voltage
12 VDC
24 VDC
Resistance
at 20°C
8.8 ohms
33.8 ohms
Initial
Current
Draw
1.4 amps
0.7 amps
Power
17.2 watts
16.6 watts
EG/Z*
Coil
Part No.
EJ/Z*
Coil
Part No.
EG
Coil
Part No.
EJ
Coil
Part No.
* Models with Zener Diode
4305872
4305874
4305912
4305924
4305862
4305864
4306112
4306124
136 g. (4.8 oz.)
136 g. (4.8 oz.)
110
120
60 70 80 90 10050403020100-20 -10-30-40
100
80
90
70
60
50
% OF RATED VOLTAGE
AMBIENT TEMPERATURE (C)
CONTINUOUS DUTY OPERATING RANGE
Minimum Voltage Required for Pull-In; 32 cSt/150 sus oil at 40°C
Operating Range
Dual Coil for SP08-47, SP08-57,
SP08-58, SV08-47, SV08-58 valves
Dual Coil for SP08-47, SP08-57,
SP08-58, SV08-47, SV08-58 valves
1.11
28.1
0.21
5.31
1.43
36.3
1.41
35.8
26.4
DIA.
2.92
74.2
INCH
MILLIMETRE
1.14
29.0
INCH
MILLIMETRE
2.92
74.2
1.41
35.8
1.40
35.6
DIA.
1.44
36.6
3.400.10
Series E Environmental Coils
®
HYDRAFORCE
HYDRAFORCE
.com
®
10-SIZE SERIES E COILS (Also for use on 12, 16, 20, 38 and 58 size poppet valves and 90-size spool valves)
1.96
49.9
3.98
101. 1
1.84
46.7
1.62
41.1
DIA.
1.96
49.9
3.98
101. 1
1.84
46.7
1.65
41.9
DIA.
INCH
MILLIMETRE
INCH
MILLIMETRE
ER
IP69K Rated 10-Size Coil
Thermal Shock Dunk Test Rated Coil
Deutsch DT04-2P Connector
Mating Connector: Deutsch No. DT06-2S; HF Part No. 4001417
EY
IP69K Rated 10-Size Coil
Thermal Shock Dunk Test Rated Coil
Metri-Pack
®
150 Connector
Mating Connector: Delphi Packard No. 12052641; HF Part No. 6110119
Please note: Electrical specifications for Series E coils differ from those for standard
HydraForce coils. (Refer to page 3.200.1 for standard coil specifications.)
Coil
Weight
Operating
Voltage
10 VDC
12 VDC
20 VDC
24 VDC
Resistance
at 20°C
5.0 ohms
7.1 ohms
19.1 ohms
28.5 ohms
Initial
Current
Draw
2.0 amps
1.7 amps
1.0 amps
0.8 amps
Power
20.0 watts
20.5 watts
19.1 watts
18.2 watts
ER/Z*
Coil
Part No.
ER
Coil
Part No.
EY/Z*
Coil
Part No.
EY
Coil
Part No.
* Models with Zener Diode
4303710
4303712
4303720
4303724
4303910
4303912
4303924
4303510
4303512
4303520
4303524
4304110
4304112
4304120
4304124
408 g. (14.4 oz.)
408 g. (14.4 oz.)
408 g. (14.4 oz.)
408 g. (14.4 oz.)
110
120
60 70 80 90 10050403020100-20 -10-30-40
100
80
90
70
60
50
% OF RATED VOLTAGE
AMBIENT TEMPERATURE (C)
Operating Range
CONTINUOUS DUTY OPERATING RANGE
Minimum Voltage Required for Pull-In; 32 cSt/150 sus oil at 40°C
Dual Coil for SP10-47, SP10-57,
SP10-58, SV10-47, SV10-57, SV10-58
Dual Coil for SP10-47, SP10-57,
SP10-58, SV10-47, SV10-57, SV10-58
3.400.11
Series E Environmental Coils
COILS AND ELECTRONIC CONTROLS
EL
IP69K Rated 10-Size Coil — Thermal Shock Dunk Test Rated Coil
1.96
49.9
1.84
46.7
1.72
43.7
DIA.
INCH
MILLIMETRE
3.98
10 1. 1
HYDRAFORCE
.com
®
10-SIZE SERIES E COILS (Also for use on 12-size poppet valves and 16-size poppet valves)
Note: Electrical specifications for Series E coils differ from those for standard
HydraForce coils. (Refer to page 3.200.1 for standard coil specifications.)
Coil
Weight
Operating
Voltage
10 VDC
12 VDC
20 VDC
24 VDC
Resistance
at 20°C
5.0 ohms
7.1 ohms
19.1 ohms
28.5 ohms
Initial
Current
Draw
2.0 amps
1.7 amps
1.0 amps
0.8 amps
Power
20.0 watts
20.5 watts
19.1 watts
18.2 watts
* Models with Zener Diode
4307112
4307124
4305710
4305712
4305720
4305724
4317210
4317212
4317224
408 g. (14.4 oz.)
408 g. (14.4 oz.)
408 g. (14.4 oz.)
408 g. (14.4 oz.)
110
120
60 70 80 90 10050403020100-20 -10-30-40
100
80
90
70
60
50
% OF RATED VOLTAGE
AMBIENT TEMPERATURE (C)
Operating Range
CONTINUOUS DUTY OPERATING RANGE
Minimum Voltage Required for Pull-In; 32 cSt/150 sus oil at 40°C
Dual Coil for SP10-47, SP10-57,
SP10-58, SV10-47, SV10-57, SV10-58
EL/Z* Coil
18" Wire
Part No.
EL Coil
18" Wire
Part No.
EL Coil
36" Wire
Part No.
3.400.12
Series E Environmental Coils
10-SIZE SERIES E COILS (Also for use on 12-size poppet valves and 16-size poppet valves)
®
HYDRAFORCE
HYDRAFORCE
.com
®
Note: Electrical specifications for Series E coils differ from those for standard
HydraForce coils. (Refer to page 3.200.1 for standard coil specifications.)
EG
IP65 Rated 10-Size Coil; DIN 43650 Connector
IP67 rated if used with sealed mating connector and gasket
Coil
Weight
Operating
Voltage
10 VDC
12 VDC
20 VDC
24 VDC
Resistance
at 20°C
5.0 ohms
7.1 ohms
19.1 ohms
28.5 ohms
Initial
Current
Draw
2.0 amps
1.7 amps
1.0 amps
0.8 amps
Power
20.0 watts
20.5 watts
19.1 watts
18.2 watts
EG/Z*
Coil
Part No.
EJ/Z*
Coil
Part No.
EG
Coil
Part No.
EJ
Coil
Part No.
* Models with Zener Diode
4305891
4305892
4305893
4305894
4305412
4305424
4305881
4305882
4305883
4305884
4305612
4305624
408 g. (14.4 oz.)
408 g. (14.4 oz.)
408 g. (14.4 oz.)
408 g. (14.4 oz.)
110
120
60 70 80 90 10050403020100-20 -10-30-40
100
80
90
70
60
50
% OF RATED VOLTAGE
AMBIENT TEMPERATURE (C)
Operating Range
CONTINUOUS DUTY OPERATING RANGE
Minimum Voltage Required for Pull-In; 32 cSt/150 sus oil at 40°C
Dual Coil for SP10-47, SP10-57,
SP10-58, SV10-47, SV10-57, SV10-58
Dual Coil for SP10-47, SP10-57,
SP10-58, SV10-47, SV10-57, SV10-58
3.98
101.1
1.84
46.7
1.25
31.8
DIA.
INCH
MILLIMETRE
1.96
49.9
1.14
29.0
1.10
27.9
0.75
19.1
1.96
49.9
3.98
101.1
1.84
46.7
1.62
41.1
DIA.
INCH
MILLIMETRE
EJ
IP67 Rated 10-Size Coil
Amp Jr. Timer Connector
3.400.13
Series E Environmental Coils
COILS AND ELECTRONIC CONTROLS
70-SIZE SERIES E COILS (For use on PFR and PV valves and on 10-, 12- and 16-size valves. )
2.45
62.3
1.84
46.7
1.62
41.1
DIA.
2.45
62.3
1.84
46.7
1.65
41.9
DIA.
INCH
MILLIMETRE
INCH
MILLIMETRE
ER
IP69K Rated 70-Size Coil
Thermal Shock Dunk Test Rated Coil
Deutsch DT04-2P Connector
Mating Connector: Deutsch No. DT06-2S
HF Part No. 4001417
EY
IP69K Rated 70-Size Coil
Thermal Shock Dunk Test Rated Coil
Metri-Pack
®
150 Connector
Mating Connector: Delphi Packard No. 12052641
HF Part No. 6110119
HYDRAFORCE
.com
®
Note: Electrical specifications for Series E coils differ from those for standard HydraForce coils.
(Refer to page 3.200.1 for standard coil specifications.)
ER Coil
Part No.
EY Coil
Part No.
Operating
Voltage
Resistance
at 20°C
Initial
Current Draw Power
Coil
Weight
4303212
4303224
4303112
4303124
12 VDC
24 VDC
4.5 ohms
17.9 ohms
2.7 amps
1.3 amps
32.8 watts
30.3 watts
408 g. (14.4 oz.)
408 g. (14.4 oz.)
110
120
60 70 80 90 10050403020100-20 -10-30-40
100
80
90
70
60
50
% OF RATED VOLTAGE
AMBIENT TEMPERATURE (C)
Operating Range
CONTINUOUS DUTY OPERATING RANGE
Minimum Voltage Required for Pull-In; 32 cSt/150 sus oil at 40°C
3.400.14
Series E Environmental Coils
EHPR-SIZE SERIES E COILS (Also for use on TS08-27, PV08 and 42-size valves.)
1.34
34.0
1.40
35.6
1.53
38.9
INCH
MILLIMETRE
1.53
38.9
DIA.
1.34
34.0
1.46
37.1
DIA.
3.12
79.2
3.12
79.2
INCH
MILLIMETRE
Note: Electrical specifications for Series E coils differ from those for standard
HydraForce coils. (Refer to page 3.200.1 for standard coil specifications.)
®
HYDRAFORCE
HYDRAFORCE
.com
®
4304712
4304724
4320712
4320724
ER Coil
Part No.
EY Coil
Part No.
4304812
4304824
Operating
Voltage
12 VDC
24 VDC
Resistance
at 20°C
5.4 ohms
21.7 ohms
Initial
Current Draw
2.2 amps
1.1 amps
Power
26.1 watts
26.3 watts
Coil
Weight
136 g. (4.8 oz.)
136 g. (4.8 oz.)
110
120
60 70 80 90 10050403020100-20 -10-30-40
100
80
90
70
60
50
% OF RATED VOLTAGE
AMBIENT TEMPERATURE (C)
CONTINUOUS DUTY OPERATING RANGE
Minimum Voltage Required for Pull-In; 32 cSt/150 sus oil at 40°C
Operating Range
ER
IP69K Rated 08-Size Coil
Thermal Shock Dunk Test Rated Coil
Deutsch DT04-2P Connector
Mating Connector: Deutsch No. DT06-2S
HF Part No. 4001417
EY
IP69K Rated 08-Size Coil
Thermal Shock Dunk Test Rated Coil
Metri-Pack
®
150 Connector
Mating Connector: Delphi Packard No. 12052641
HF Part No. 6110119
1.34
34.0
1.40
35.6
1.53
38.9
INCH
MILLIMETRE
1.53
38.9
DIA.
1.34
34.0
1.46
37.1
DIA.
3.12
79.2
3.12
79.2
INCH
MILLIMETRE
ER/Z* Coil
Part No.
* Models with Zener Diode
Coil
Weight
3.400.15
Series E Environmental Coils
COILS AND ELECTRONIC CONTROLS
EG
IP65 Rated 12-Size Coil
DIN 43650 Connector
Can be IP67 rated if used with
sealed mating connector
and gasket
12-SIZE SERIES E COILS (For 12 Size Spool Valves Only)
2.19
55.6
3.03
76.8
3.03
76.8
1.81
45.9
2.19
55.6
INCH
MILLIMETRE
3.03
76.8
1.80
45.7
2.19
55.6
1.77
44.9
110
120
60 7050403020100-20 -10-30-40
100
80
90
70
60
50
% OF RATED VOLTAGE
AMBIENT TEMPERATURE (C)
CONTINUOUS DUTY OPERATING RANGE
Minimum Voltage at the Coil Required for Pull-In
32 cSt/150 sus oil at 40ºC (104ºF)
Operating Range
EY
IP69K Rated 12-Size Coil
Thermal Shock Dunk Test Rated
Metri-Pack
®
150 Connector
Mating Connector:
Delphi Packard No. 12052641
HF Part No. 6110119
EG
Coil
Part No.
Operating
Voltage
Resistance
at 20°C
Initial
Current
Draw
Power
ER/Z*
Coil
Part No.
HYDRAFORCE
.com
®
ER
Coil
Part No.
EY/Z*
Coil
Part No.
EY
Coil
Part No.
* Models with Zener Diode
ER
IP69K Rated 12-Size Coil
Thermal Shock Dunk Test Rated
Deutsch DT04-2P Connector
Mating Connector:
Deutsch No. DT06-2S — HF Part No. 4001417
6964012
6964024
4302206
4302207
4301212
4301224
4305512
4305524
6956012
6956024
12 VDC
24 VDC
4.6 ohms
18.3 ohms
2.6 amps
1.3 amps
31.1 watts
31.0 watts
0.87 kg. (1.92 lbs.)
0.87 kg. (1.92 lbs.)
3.400.16
EW
IP65 Rated 12-Size Coil
Dual 18 Gauge Leads
with Weather-Pack
®
Connector
Mating Connector: Delphi Packard No. 12015792
12-SIZE SERIES E COILS (For 12 Size Spool Valves Only)
ES
IP65 Rated 12-Size Coil
Dual Spades SAE J858a
EL
IP65 Rated 12-Size Coil
Dual Leads – 18 Gauge
110
120
60 7050403020100-20 -10-30-40
100
80
90
70
60
50
% OF RATED VOLTAGE
AMBIENT TEMPERATURE (C)
CONTINUOUS DUTY OPERATING RANGE
Minimum Voltage at the Coil Required for Pull-In
32 cSt/150 sus oil at 40ºC (104ºF)
Operating Range
Operating
Voltage
10 VDC
12 VDC
24 VDC
Resistance
at 20°C
3.2 ohms
4.6 ohms
18.3 ohms
Initial
Current Draw
3.1 amps
2.6 amps
1.3 amps
Power
31.2 watts
31.1 watts
31.0 watts
Coil
Weight
0.87 kg. (1.92 lbs.)
0.87 kg. (1.92 lbs.)
0.87 kg. (1.92 lbs.)
6853012
6853024
EW Coil
Part No.
6852010
6852012
6852024
EL Coil
Part No.
6851012
6851024
ES Coil
Part No.
Series E Environmental Coils
®
HYDRAFORCE
HYDRAFORCE
.com
®
2.19
55.6
3.03
76.8
2.19
55.6
3.03
76.8
2.19
55.6
3.03
76.8
1.79
45.6
1.66
42.15
7.00
199.15
16.34
415
Approx.
Lead Length:
INCH
MILLIMETRE
1.66
42.15
Series E Environmental Coils
COILS AND ELECTRONIC CONTROLS
3.400.17
SERIES E COILS PART NUMBER CROSS REFERENCE
Original Design
Manuf. before 1-1-04
New Design
Manuf. after 1-1-04
08-Size
E-Coils
Code EY
Metri-Pack
®
150
Connector
Top view shown
w/o retaining nut
10 VDC
12 VDC
20 VDC
24 VDC
4300110
4300112
4300124
4303410
4303412
4303420
4303424
Code ER
Deutsch DT04-2P
Connector
Top view shown
w/o retaining nut
10 VDC
12 VDC
20 VDC
24 VDC
4300310
4300312
4300324
4303610
4303612
4303620
4303624
Original Design
Manuf. before 1-1-04
New Design
Manuf. after 1-1-04
10-Size
E-Coils
Code EY
Metri-Pack
®
150
Connector
Top view shown
w/o retaining nut
10 VDC
12 VDC
20 VDC
24 VDC
4300210
4300212
4300224
4303510
4303512
4303520
4303524
Code ER
Deutsch DT04-2P
Connector
Top view shown
w/o retaining nut
10 VDC
12 VDC
20 VDC
24 VDC
4300410
4300412
4300424
4303710
4303712
4303720
4303724
1.41
35.8
DIA.
1.41
35.8
DIA.
1.41
35.8
DIA.
1.41
35.8
DIA.
1.84
46.7
DIA.
1.84
46.7
DIA.
1.84
46.7
DIA.
1.84
46.7
DIA.
SERIES E COIL NUT & SPACER CROSS REF. FOR SPxx-47 & SVxx-47 DUAL SOLENOID VALVES
Retaining Nut and
Spacer for Original
E-Coil Design
Manuf. before 1-1-04
Retaining Nut and
Spacer for New
E-Coil Design
Manuf. after 1-1-04
Nut: 4502960 Nut: 7004400
Nut: 4528150 Nut: 4528180
Spacer: 4514810 Spacer: 4534720
Coil Spacer
for all SP08-47
& SV08-47
Series Valves
(installs between
the two coils)
Part Number:
Retaining Nut and
Spacer for Original
E-Coil Design
Manuf. before 1-1-04
Retaining Nut and
Spacer for New
E-Coil Design
Manuf. after 1-1-04
For SP10-47
& SV10-47
Series Valve
Retaining Nut
for SP10-47’s
& SV10-47’s
without Manual
Override
Part Number:
Nut: 4502960 Nut: 7004400
Nut: 4527160 Nut: 4527540
Spacer: 4514130 Spacer: 4539700
Retaining Nut
for SP10-47M’s
& SV10-47M’s
with Manual
Override
Part Number:
Coil Spacer
for all SP10-47
& SV10-47
Series Valves
(installs between
the two coils)
Part Number:
1.41
35.8
O.D.
1.41
35.8
O.D.
1.84
46.6
O.D.
1.84
46.6
O.D.
For SP08-47
& SV08-47
Series Valves
Retaining Nut
for SP08-47’s
& SV08-47’s
without Manual
Override
Part Number:
Retaining Nut
for SP08-47M’s
& SV08-47M’s
with Manual
Override
Part Number:
HYDRAFORCE
.com
®
3.400.18
Series E Environmental Coils
SERIES E COIL NUT CROSS REFERENCE
Retaining Nuts
for Original
E-Coil Design
Valve Models
SF08-20
SP08-20
SV08-20
SV08-22
SV08-24
SV08-25
SV08-26
SV08-31
Nut: 4502960
Nut: 7004400
Nut: 4626260-1
Nut: 7004490
Retaining Nuts
for New E-Coil
Design
SV08-33
SV08-40
SV08-41
SV08-42
SV08-43
SV08-44
SV08-45
SV08-46
SF08-20M/J/Y
SV08-20M/J/Y
SV08-22M/J/Y
SV08-24M/J/Y
SV08-25M/J/Y
SV08-26M/J/Y
SV08-31M/J/Y
SV08-33M/J/Y
SV08-40M/J/Y
SV08-41M/J/Y
SV08-42M/J/Y
SV08-43M/J/Y
SV08-44M/J/Y
SV08-45M/J/Y
SV08-46M/J/Y
SF08-21
SV08-21
SV08-21P/K
SV08-23
SV08-23P/K
Nut: 4514800 Nut: 7004410
SP10-20
SP10-41
SP10-46R
SP12-20
SV10-20
SV10-22
SV10-24
SV10-25
SV10-30
SV10-31
SV10-33
SV10-34
SV10-40
SV10-41
SV10-42
SV10-43
SV10-44
SV10-45
SV12-20
SV12-22
SV16-20
SV16-22
SV38-20
SV58-xx
Nut: 4502960
Nut: 7004400
SF10-20M/J/Y
SV10-22M/J/Y
SV10-24M/J/Y
SV10-25M/J/Y
SV10-30M/J/Y
SV10-31M/J/Y
SV10-33M/J/Y
SV10-34M/J/Y
SV10-40M/J/Y
SV10-41M/J/Y
SV10-42M/J/Y
SV10-43M/J/Y
SV10-44M/J/Y
SV10-45M/J/Y
SV38-20M/J/Y
SV58-xxM/J/Y
SP10-21
SP10-24
SV10-21
SV10-21P/K
SV10-23
SV10-23P/K
SV38-38
SV38-38P/K
Manufactured
before 1-1-04
Manufactured
after 1-1-04
Retaining Nuts
for Original
E-Coil Design
Valve Models
Nut: 4626260-2 Nut: 7004590
Nut: 4503610
Nut: 7004420
Retaining Nuts
for New E-Coil
Design
Nut: 4514800
Nut: 7004410
Nut: 4526330
Nut: 4540560
Manufactured
before 1-1-04
Manufactured
after 1-1-04
TS08-20
TS80-30
TS98-30
TS98-31
TS10-27
TS12-27
TS38-21
TS10-26
TS10-36
TS12-26
TS12-36
TS38-20
Nut: 4519810
Nut: 4540550
®
HYDRAFORCE
HYDRAFORCE
.com
®