PRESSURE CONTROLS
RV50-28 Relief, Pilot-Operated w/Reverse Check
DESCRIPTION
A screw-in, cartridge-style, pilot-operated, two-stage, hydraulic relief valve with
reverse flow check valve. It is intended for use as a pressure limiting device in
demanding hydraulic circuits which require fast response, low hysteresis, low leak-
age, low pressure overshoot and reverse free flow features.
OPERATION
The RV50-28 blocks flow from 1 to 2 until sufficient pressure is present at 1 to force
the pilot stage open, allowing the main stage to shift, opening 1 to 2.
The relief flow path is from 1 to 2. Reverse flow, from 2 to 1, occurs when the
pressure at 2 is at least 2.1 bar (30 psi) higher than at port 1.
FEATURES
• Adjustments cannot be backed out of the valve.
• Hardened spool and cage for long life.
• Fast response.
• Industry common cavity.
RATINGS
Operating Pressure Range: 344 bar (5000 psi)
Proof Pressure: 621 bar (9000 psi)
Burst Pressure: 241 bar (8000 psi)
Flow: 113.6 lpm (30 gpm) rom port 1 to port 2
Adjustable Pressure Range: 17 bar (250 psi) to 345 bar (5000 psi)
Internal Leakage: 0.5 ml/minute (10 drops/minute) max. to 80% of nominal setting
Crack Pressure Defined: bar (psi) evident at 7.6 lpm (2.0 gpm) attained
Reseat Pressure: Nominal 90% of crack pressure
Check Valve Mode Crack Pressure: 2.1 bar (30 psi)
Approximate Pressure Increment per Adjuster Turn: 99 bar (430 psi)/turn
Response Time: Relief Valve to Check Valve at 24 bar/53 lpm (3500 psi/14 gpm)
condition: 0.6 seconds
Response Time: Check Valve to Relief Valve at 24 bar/53 lpm (3500 psi/14 gpm)
condition: 0.3 seconds
Operating Temperature: with polyurethane seals: -54 to 107°C (-65 to 225°F)
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC10-2; See page 9.110.1
Cavity Tool: CT10-2XX; See page 8.600.1
Seal Kit: SK10-2X-B; See page 8.650.1
ISO SYMBOL
PERFORMANCE
(Cartridge Only)
6.173.1
414/6000
344/5000
276/4000
138/2000
70/1000
38
10
19
5
57
15
95
25
76
20
FLOW lpm/gpm
PRESSURE bar/psi
114
30
Relief Valve Mode
32 cSt/150 sus oil at 40°C
207/3000
10.3/150
6.9/100
8.6/125
3.4/50
1.7/25
5.2/75
19
5
57
15
38
10
76
20
FLOW lpm/gpm
PRESSURE bar/psi
95
25
114
30
Check Valve Mode
32 cSt/150 sus oil at 40°C
HYDRAFORCE
.com
®
Blue rectangles are links to other catalog pages.