FLOW CONTROLS
FD50-44 Flow Divider/Combiner . . . Heavy Duty,
DESCRIPTION
High performance, high pressure, multifunction, screw-in, cartridge-style, spool-type
ow divider/combiner.
OPERATION
In the dividing mode, the FD50-44 will divert input fl ow from port to ports
and , based on the ratio specifi ed. This valve provides a highly accurate, pressure
compensated division of inlet fl ow or combination of return fl ow regardless of system
operating pressure. When the fl ow direction is reversed, the valve will combine fl ows
from ports
and to port .
FEATURES
Hardened parts for long life.
Quiet, modulated response.
Wide operating fl ow range.
Accurate division or combination of fl ow.
Industry common cavity.
RATINGS
Operating Pressure: 345 bar (5000 psi)
Pressure Drop: 24 bar (350 psi) at maximum inlet fl ow
Flow Range Options:
Model Code 11: 50:50 rated @ 2.5–9.5 lpm (0.7–2.5 gpm) input
Model Code 22: 50:50 rated @ 4–19 lpm (1.0–5.0 gpm) input
Model Code 44: 50:50 rated @ 7.5–38 lpm (2.0–10.0 gpm) input
Flow Accuracy: 5% of inlet fl ow at maximum fl ow rate;
10% of inlet fl ow at minimum fl ow rate
Temperature: -40 to 120°C
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Note: Standard 10 size 4-way bodies should not be used with this product.
See page 8.010.1 for special fl ow divider bodies.
Cavity: VC10-4 (Variation “A”); See page 9.110.1
Cavity Tool: CT10-4X; See page 8.600.1
Seal Kit: SK10-4X-MMM; See page 8.650.1
SYMBOLS
5.630.1
USASI:
PERFORMANCE (Cartridge Only)
22.7/6
18.9/5
15.1/4
11.4/3
7.6/2
138
2000
207
3000
69
1000
276
4000
345
5000
PRESSURE DROP bar/psi
FLOW PER PORT lpm/gpm
Pressure Drop vs. Inlet Flow
to , Model Code 44, Dividing Mode
—— FL4; - - - FL2
32 cSt/150 ssu oil at 40°C
3.8/1
HYDRAFORCE
.com
®
ISO:
7.6
2.0
3.8
1.0
11.4
3.0
18.9
5.0
29.5
7.0
34.1
9.0
15.1
4.0
22.7
6.0
30.3
8.0
37.9
10.0
FLOW lpm/gpm
PRESSURE DROP bar/psi
Inlet Flow vs Pressure Drop
Dividing Mode; Inlet at
32 cSt/150 ssu oil at 40nC
27.6/400
24.1/350
20.7/300
17.2/250
13.8/200
10.3/150
6.9/100
3.4/50
11
22
44
Blue rectangles are links to other catalog pages.
Cartridge: Weight: 0.11 kg. (0.25 lbs.)
Steel with hardened work surfaces.
Zinc-plated exposed surfaces.
Buna N O-rings and polyester
elastomer back-ups standard.
Special Ported Body: Ductile iron,
required for operation over 207 bar
(3000 psi). Aluminum bodies are
available for lower pressure
operation. See page 8.010.1
MATERIALS TO ORDER
FD50-44 - __ __ __ - __ - __ __
Special FD-Type
Ductile Iron Ported Bodies
Cartridge Only 0
SAE 6 (all ports) 6TD
SAE 8 (all ports) 8TD
SAE 8 port
;
SAE 6 ports
& 8DD
1/4 in. BSP* (all ports) 2BD
3/8 in. BSP* (all ports) 3BD
*BSP Body; U.K. Mfr. Only
Dividing/Combining Ratio
11 50:50 rated @ 2.5–9.5 lpm
(0.7–2.5 gpm) input
22 50:50 rated @ 4–19 lpm
(1.0–5.0 gpm) input
44 50:50 rated @ 7.5–38 lpm
(2.0–10.0 gpm) input
Seals
N Buna N (Std.)
V Fluorocarbon
P Polyurethane
(required for
operation over 241 bar/3500 psi)
NOTE: Standard 10-size 4-way bodies
should not be used for fl ow dividers.
See Special, FD-type, fl ow divider
bodies, page 8.010.1.
FD50-44
5.630.2
DIMENSIONS
Ductile Iron, FD-Type
Body Shown
2.56
65.0
0.75
19.1
3.38
85.7
1.00
25.4
2.84
72.1
2.50
63.5
1.26
32.0
1.38
34.9
Thru 2
Places
ACROSS FLATS
0.28
7.1
1.99
50.6
1.36
34.6
0.31
7.9
2.00
50.8
0.28
7.1
22–25 ft-lbs (30–34 Nm)
Installation Torque:
Port
is not used.
Multifunction
®
HYDRAFORCE
HYDRAFORCE
.com
®
Blue rectangles are links to other catalog pages.