FLOW CONTROLS
EC50-42 Pressure Compensator, High Pressure
USASI/ISO:
SYMBOLS
PERFORMANCE
(Cartridge Only)
5.466.1
37.9/10
30.3/8
22.7/6
15.1/4
0
7.6/2
069
1000
138
2000
Bypass P > Priority P Priority P > Bypass P
207
3000
276
4000
345
5000
69
1000
138
2000
207
3000
276
4000
345
5000
LOAD PRESSURE bar/psi
FLOW lpm/gpm
Priority Flow vs. Load
12 gpm Inlet Flow; 150 psi Compensator Spring
32 cSt/150 sus oil at 40°C
45.4/12
DESCRIPTION
A screw-in, cartridge-style, priority-on-demand, pressure-compensator with a static
load sense, intended to provide priority fl ow in the required amount, while allowing
excess fl ow to be used for auxiliary functions.
OPERATION
With inlet fl ow at ➂, the EC50-42 will deliver required priority fl ow at ➃, regardless of
load pressure. Excess fl ow exits at
➁. Port ➀ is the load sense port. All ports may be
fully pressurized.
FEATURES
• Hardened parts for long life.
• Quiet, modulated response.
• Industry common cavity.
RATINGS
Operating Pressure: Inlet: 345 bar (5000 psi)
Input Flow Rate: 45.4 lpm (12 gpm) maximum
Maximum Regulated Flow: 37.9 lpm (10 gpm) with 10.3 bar (150 psi) compensator
spring; 30.2 lpm (8.0 gpm) with 5.5 bar (80 psi) compensator spring
Flow Maintenance: see performance chart
Temperature: -40 to 120°C
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC10-4; See page 9.110.1
Cavity Tool: CT10-4-XXX; See page 8.600.1
Seal Kit: SK10-4P-TMB; See page 8.650.1
HYDRAFORCE