FLOW CONTROLS
EC10-42 Pressure Compensator
USASI/ISO:
SYMBOLS
PERFORMANCE
(Cartridge Only)
5.462.1
15.5/225
13.8/200
12.1/175
10.3/150
8.6/125
1.7/25
3.4/50
6.9/100
5.2/75
7.5
2
15.1
4
22.7
6
30.2
8
37.9
10
45.4
12
53.0
14
60.6
16
FLOW lpm/gpm
PRESSURE DROP bar/psi
Pressure Drop vs. Inlet Flow
➂ to ➁; Port ➃ closed; Port ➁ no load;
150 psi Compensator Spring
32 cSt/150 ssu oil at 40°C
17.2/250
DESCRIPTION
A screw-in, cartridge-style, priority-on-demand, pressure-compensator with a static
load sense, intended to provide priority fl ow in the required amount, while allowing
excess fl ow to be used for auxiliary functions.
OPERATION
With inlet fl ow at ➂, the EC10-42 will deliver required priority fl ow at ➃, regardless of
load pressure. Excess fl ow exits at
➁. Port ➀ is the load sense port. All ports may be
fully pressurized.
FEATURES
• Hardened parts for long life.
• Quiet, modulated response.
• Industry common cavity.
RATINGS
Operating Pressure: Inlet: 240 bar (3500 psi)
Maximum Regulated Flow: 37.9 lpm (10 gpm) with 10.3 bar (150 psi) compensator
spring; 30.2 lpm (8.0 gpm) with 5.5 bar (80 psi) compensator spring
Flow Maintenance: see performance chart
Temperature: -40 to 120°C with Buna N seals
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC10-4; See page 9.110.1
Cavity Tool: CT10-4-XXX; See page 8.600.1
Seal Kit: SK10-4X-MMM; See page 8.650.1
HYDRAFORCE
.com
®