FLOW CONTROLS
EC16-40 Pressure Compensator
DESCRIPTION
A screw-in, cartridge-style pressure-compensating element, intended for use with
a remote fi xed or variable orifi ce to yield a three-port (bypass-type), pressure-
compensated, fl ow regulating hydraulic valve.
OPERATION
The EC16-40 maintains a constant fl ow rate from regardless of load pressure
changes in the circuit downstream of
.
The cartridge maintains a constant differential pressure from circuit point P to
port
(see USASI Symbol), thereby regulating the hydraulic fl ow rate between the
two points in the circuit. The EC16-40 is a priority type regulator, delivering pump
ow fi rst to
, then bypassing excess to . All ports may be fully pressurized.
FEATURES
Hardened parts for long life.
Quiet, modulated response.
Industry common cavity.
RATINGS
Operating Pressure: 240 bar (3500 psi)
Flow Rate: 100 lpm (26.5 gpm) max. regulated; 180 lpm (47.5 gpm) max. input.
Pressure at
begins to rise higher than compensating pressure differential
when bypass fl ow exceeds 80 lpm (21 gpm).
Standard Compensator Bias Spring: 5.5 bar (80 psid)
Flow Maintenance: 7.57 to 98.4 lpm (2 to 26 gpm) settings ±10%
Temperature: -40 to 120°C
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC16-4; See page 9.116.2
Cavity Tool: CT16-4XX; See page 8.600.1
Seal Kit: SK16-4X-TMB; See page 8.650.1
SYMBOLS
USASI/ISO:
PERFORMANCE (Cartridge Only)
5.454.1
10.1/0.40
8.9/0.35
7.6/0.30
6.4/0.25
5.1/0.20
ORIFICE DIAMETER mm/inch
Output Flow vs. Orifice Dia.
with 80 psid Spring
32 cSt/150 ssu oil at 40°C
18.9
5
37.9
10
56.8
15
FLOW lpm/gpm
75.8
20
3.8/0.15
94.6
25
2.5/0.10
1.3/0.05
113.6
30
HYDRAFORCE
.com
®
Blue rectangles are links to other catalog pages.
Cartridge: Weight: 0.36 kg. (0.80 lbs.)
Steel with hardened work surfaces.
Zinc-plated exposed surfaces.
Buna N O-rings and polyester
elastomer back-ups standard.
Ported Body: Not available; consult
factory.
MATERIALS TO ORDER
EC16-40
DIMENSIONS
5.454.2
EC16-40 - __ __ __ - __ - __
Compensator Spring
40 2.8 bar (40 psid)
80 5.5 bar (80 psid) standard
160 11.0 bar (160 psid)
Seals
N Buna N (Std.)
V Fluorocarbon
Porting
Cartridge Only 0
®
HYDRAFORCE
HYDRAFORCE
.com
®