PRESSURE CONTROLS
FRRV10-41F Priority Flow Regulator . . .
DESCRIPTION
A screw-in, cartridge-style, multi-function valve which includes a fi xed-compensated,
priority-type fl ow regulator and an adjustable pressure relief valve in one cartridge.
OPERATION
The FRRV10-41F maintains a constant fl ow rate from port ➂ regardless of load
pressure changes at priority port
➂ or bypass port ➁. When load pressure at ➂
reaches the setting of the relief valve, fl ow is dumped over the relief at
➃.
The exit fl ow from the relief can be connected to tank or to the bypass fl ow.
Note: Back pressure at port
➃ is directly additive to the relief setting.
FEATURES
• Two valve functions in one, industry-common cavity.
• Adjustments cannot be backed out of the valve.
• Relief valve adjustments prohibit relief valve spring from going solid.
• Quiet, modulated response.
• Hardened parts for long life.
RATINGS
Maximum Operating Pressure: 207 bar (3000 psi)
Maximum System Pressure: 276 bar (4000 psi)
Priority Flow: 19 lpm (5.0 gpm) maximum regulated
Inlet Flow: 38 lpm (10.0 gpm) maximum
Relief Valve Pressure Setting Ranges: 17 to 207 bar (250 to 3000 psi)
Temperature: -40 to 120°C with standard Buna seals
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC10-4; See page 9.110.1
Cavity Tool: CT10-4XX; See page 8.600.1
Seal Kit: SK10-4X-MMM; See page 8.650.1
USASI/ISO:
PERFORMANCE (Cartridge Only)
SYMBOLS
5.390.1
35
500
69
1000
103
1500
138
2000
172
2500
207
3000
PRESSURE bar/psi
FLOW lpm/gpm
Priority Flow vs. Priority Pressure
at 30.3 lpm/8 gpm Inlet Flow
32 cSt/150 ssu oil at 40°C
22.7/6
18.9/5
15.1/4
11.4/3
7.6/2
3.8/1
U.S. Patent