FLOW CONTROLS
DESCRIPTION
A manually adjustable, pressure-compensated, bi-directional fl ow control valve.
An internal compensator spool provides compensated fl ow across the proportional
orifi ce regardless of fl ow direction.
OPERATION
The FR12-32 provides regulated fl ow in both directions: from port ➁ to port ➂, or from
port
➂ to port ➁. Port ➀ should be blocked. Regulated fl ow increases from closed to
fully open with clockwise rotation. The valve will maintain the set fl ow rate regardless
of pressure variations at each of the ports.
FEATURES
• Excellent linearity and hysteresis
characteristics.
• Hardened spool and cage for long life.
• Various adjustment options.
RATINGS
Maximum Operating Pressure: 240 bar (3500 psi)
Regulated Flow: 0-50 lpm (0-13 gpm)
Internal Leakage: 0.38 lpm (0.10 gpm) maximum
Temperature: -40 to 120°C with Buna N seals
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1.
Cavity: VC12-3; See page 9.112.1
Cavity Tool: CT12-3X-XX; See page 8.600.1
Seal Kit: SK12-3X-MM; See page 8.650.1
FR12-32 Flow Regulator, Orifi ce Adjustable,
SYMBOLS
5.365.1
PERFORMANCE
Patent
Pending
2
3
1
123
TURNS
FLOW lpm/gpm
Regulated Flow vs. Turns
103 bar/1500 psi Input Pressure
32 cSt/150 ssu oil at 40°C
75.6/20
60/16
45/12
30/8
15/4
- - ➂ to ➁
— ➁ to ➂
69
1000
PRESSURE DROP bar/psi
FLOW lpm/gpm
Regulated Flow vs. Pressure Drop
240 bar/3500 psi Input Pressure
32 cSt/150 ssu oil at 40°C
138
2000
207
3000
75.6/20
60/16
45/12
30/8
15/4
— ➁ to ➂
- - ➂
to ➁
3 TURNS
2 TURNS
1 TURN
1.5 TURNS
0.5 TURN
ABBREVIATED SYMBOL:
HYDRAFORCE
.com
®