FLOW CONTROLS
FR16-30F Regulator, Pressure-Compensated
DESCRIPTION
A screw-in, cartridge-style, pressure-compensated, non-adjustable fl ow regulator,
intended for use in fi xed displacement hydraulic circuits requiring partial pump fl ow
diversion on a priority basis.
OPERATION
The FR16-30F maintains a constant fl ow rate from regardless of load pressure
changes in the system downstream of
, or in the bypass leg at .
The valve’s spool maintains a constant differential pressure of 5.5 bar (80 psi) across
a fi xed internal orifi ce, thereby regulating the hydraulic fl ow rate from
to .
The FR16-30F is a priority type regulator, delivering the pump fl ow to
rst, then
bypassing excess to
. All ports may be fully pressurized.
Flow out of priority port
may vary based on input fl ow amount, particularly with
lower temperatures and increased fl uid viscosities. Settings may need to be
established through correlation study. Consult factory.
FEATURES
Hardened parts for long life.
Quiet, modulated response.
RATINGS
Operating Pressure: 241 bar (3500 psi)
Flow Rate: 113 lpm (30.0 gpm) max. priority; 190 lpm (50.0 gpm) max. input
Standard Compensator Bias Spring: 5.5 bar (80 psid) differential
Flow Maintenance Setting Range: up to 76 lpm (20 gpm) to accuracy of ±10%;
76 to 114 lpm (20 to 30 gpm) to accuracy of ±15%
Temperature: -40 to 120°C
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC16-3; See page 9.116.1
Cavity Tool: CT16-3XX; See page 8.600.1
Seal Kit: SK16-3X-MM; See page 8.650.1
USASI: ISO:
PERFORMANCE (Cartridge Only)
SYMBOLS
5.346.1
Pressure Drop vs. Inlet Flow
32 cST/150 sus oil at 40°C
1.7/25
3.4/50
5.2/75
6.9/100
PRESSURE DROP lbar/psi
18.9
5
INLET FLOW lpm/gpm
113.6
30
132.5
35
94.4
25
75.8
20
56.8
15
37.9
10
Priority Flow vs. Pressure
at 241 bar/3500 psi; 190 lpm/50 gpm Inlet
32 cST/150 ssu oil at 40°C
75.7/20
113.5/30
151.4/40
37.9/10
FLOW lpm/gpm
Priority > Bypass
PRESSURE bar/psi
Bypass > Priority
276
4000
276
4000
138
2000
0
0
138
2000
3
2
1
HYDRAFORCE
.com
®
Blue rectangles are links to other catalog pages.
FR16-30F - __ __ __ - __ - / __ __ __ __
Cartridge: Weight: 0.49 kg. (1.07 lbs.)
Steel with hardened work surfaces.
Zinc-plated exposed surfaces.
Buna N O-rings and polyester
elastomer back-ups standard.
Standard Ported Body: Weight:
1.5 kg. (3.35 lbs.) Anodized high-
strength 6061 T6 aluminum alloy,
rated to 207 bar (3-00 psi). Ductile
iron bodies available; dimensions
may differ. See page 8.012.1.
DIMENSIONS
MATERIALS
TO ORDER
Porting
Cartridge Only 0
SAE 12 12T
SAE 16 16
Note: Compensator spring values may
be varied for OEM application to provide
changed differential pressure/output fl ow
relationships. Consult factory.
FR16-30F
5.346.2
3
3
2
2
1
1
50.8
2.00
101.6
4.00
50.3
1.98
72.9
2.87
33.7
1.33
MILLIMETRE
INCH
25.4
1.00
8.74
0.34
4.76
0.18
54.0
2.13
111.1
4.38
127.0
5.00
92.1
3.63
38.1
1.50
ACROSS
FLATS
TORQUE:
46–54 ft-lbs
(62.6–73.4 Nm)
Priority Setting
Setting in LPM
Range: 4 to 113 lpm
Specify, for example:
M20.0 20.0 lpm
M100 100 lpm
etc.
Setting in GPM
Range: 1 to 30 gpm
Specify, for example:
15.0 15 gpm
22.0 22 gpm
etc.
Drill Size Method
In thousandths of an inch.
Range: 0.63 to 0.302
Specify, for example:
D150 0.150 in. control orifi ce hole
etc.
Seals
Buna N (Std.) N
Fluorocarbon V
Note: Minimum drill diameter is 0.020 in.
For smaller orifi ce sizes consult factory.
®
HYDRAFORCE
HYDRAFORCE
.com
®
Blue rectangles are links to other catalog pages.