FLOW CONTROLS
FR10-30A Regulator, Pressure-Compensated
DESCRIPTION
A screw-in, cartridge-style, fi xed orifi ce, pressure-compensated, bypass-type
hydraulic fl ow regulating valve, with limited range adjustment from a pre-determined
nominal setting.
OPERATION
The FR10-30A maintains a constant fl ow rate from ➂ regardless of load pressure
changes in the system downstream of
➂, or in the bypass leg at ➁.
The valve will pressure-compensate once a minimum pressure drop (determined
by spring adjustment setting) is achieved from
➀ to ➂. This value will range from
approximately 4.8 to 13.8 bar (70 to 200 psid).
The cartridge may be adjusted to ±25% of nominal setting. At nominal setting,
pressure drop is approximately 9 bar (130 psid).
Flow out of priority port
➂ may vary based on input fl ow amount, particularly with
lower temperatures and increased fl uid viscosities. Settings may need to be
established through correlation study. Consult factory.
FEATURES
• Bypass port ➁ may be fully pressurized.
• Hardened steel parts for long life.
• Quiet, modulated response.
• Industry common cavity.
RATINGS
Operating Pressure: 207 bar (3000 psi)
Customer-Specifi ed Standard Flow Setting:
Low Range: 1.9 to 9.5 lpm (0.5 to 2.5 gpm);
Specify in 1.9 lpm (0.5 gpm) increments.
High Range: 11.4 to 22.7 lpm (3.0 to 6.0 gpm);
Specify in 3.8 lpm (1 gpm) increments.
See ordering table on facing page.
Pressure at
➀ begins to rise higher than compensating pressure differential
when bypass fl ow exceeds 23 lpm (6 gpm).
Temperature: -40 to 120°C
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC10-3; See page 9.110.1
Cavity Tool: CT10-3XX; See page 8.600.1
Seal Kit: SK10-3X-TB; See page 8.650.1
USASI: ISO:
PERFORMANCE (Cartridge Only)
SYMBOLS
5.342.1
22.7/6
15.1/4
7.6/2
52
750
104
1500
155
2250
PRESSURE DROP bar/psi
FLOW lpm/gpm
207
3000
Flow Maint. Characteristic -
32 cSt/150 ssu oil at 40°C
➀➂
13.8
200
6.9
100
7.5
2
15.1
4
22.7
6
BYPASS FLOW RATE lpm/gpm
30.2
8
37.9
10
PRESSURE DIFF. -
bar/psi
➀➂
NOTE: For certain applications with substantial dynamic load changes, particularly in
cases where there is high differential pressure, we recommend the use of the
FR10-33 (page 5.372.1) or the FR10-39 (page 5.382.1) in place of this valve.
HYDRAFORCE
.com
®