DIRECTIONAL VALVES
HPE42-S67K HyPerformance Proportional,
DESCRIPTION
A high pressure, screw-in, cartridge-style, proportional, spring-centered, pilot-operat-
ed spool-type hydraulic directional valve.
OPERATION
When the HPE42-S67K is in neutral position port 3 is blocked and ports 2, 4 and 5
are connected to each other. On remote pilot signal at 1, the spool shifts proportion-
ally to the applied pilot pressure to allow flow from 3 to 4 through a load such as a
hydraulic cylinder or motor and from 2 to 5, and to tank. Port 5 is to be used as a tank
port only with maximum pressure of 69 bar (1000 psi). On remote pilot signal at 6, the
spool shifts proportionally to the applied force in the opposite direction, thus reversing
the flow direction.
The spool is non-symmetrical, providing only meter-in control.
FEATURES
Hardened spool and cage for long life.
Excellent metering characteristics.
Good linearity.
All HyPerformance™ products are tested to the rigorous standards of the NFPA
specification T2.6.1 and are tested at a verification level of 90% and an assurance
of 99%.
RATINGS
Maximum Operating Pressure: Ports 2, 3, 4 (work): 350 bar (5075 psi)
(10% life cycle) 420 bar (6090 psi); Ports 1 and 6 (pilot): 35 bar (500 psi);
Port 5 (tank): 69 bar (1000 psi)
Proof Pressure: 690 bar (10000 psi)
Burst Pressure: 1380 bar (20000 psi)
Flow Rating: 170 lpm (45 gpm)
Internal Leakage: 820 ml/minute (50 cu. in./minute) at 350 bar (5075 psi)
Temperature: -54°C to 107°C (-65°F to 225°F) with urethane seals
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: HVC42-S6, Variation A; See page 9.142.1
Cavity Tool: HCT42-S6; See page 8.600.1
Seal Kit: HSK42-S6U-0000; See page 8.650.1
ISO SYMBOL
4.440.3
PERFORMANCE (Cartridge Only)
U.S. Patent
6,554,014
HYDRAFORCE
.com
®
Flow vs. Pilot Pressure
3 to 4, Port 1 Pilot - - - -
3 to 2, Port 6 Pilot ——
32 cSt/150 sus oil at 40°C
37.9/10
18.9/5
56.8/15
75.5/20
94.6/25
113.6/30
151.4/40
132.5/35
170.3/45
0 6.9
100
6.9
100
13.8
200
13.8
200
20.7
300
20.7
300
PILOT PRESSURE bar/psi
FLOW lpm/gpm
20.7/300
13.8/200
17.2/250
10.3/150
6.9/100
3.4/50
19
5
57
15
95
25
132
35
170
45
FLOW lpm/gpm
PRESSURE DROP bar/psi
Pressure Drop vs. Flow (Neutral)
2 to 5 - - - -
4 to 5 ——
32 cSt/150 sus oil at 40°C
20.7/300
13.8/200
17.2/250
10.3/150
6.9/100
3.4/50
19
5
57
15
95
25
132
35
170
45
FLOW lpm/gpm
PRESSURE DROP bar/psi
Pressure Drop vs. Flow (Piloted)
3 to 2 and 4 to 5 ——
32 cSt/150 sus oil at 40°C
2 to 5 - - - -; 3 to 4
Blue rectangles are links to other catalog pages.
DIMENSIONS
HPE42-S67K
4.440.4
6.14
155.9
3.56
90.4
INCH
MILLIMETRE
0.50
12.7
2.15
54.7
4.75
120.7
8.25
209.6
3.45
87.7
6.05
153.7
0.59
15.1
2.72
69.1
2.50
57.2
5.00
114.3
2.00
38.1
4.00
76.2
0.50
12.7
M42 x 2 – 6g
0.75
19.1
0.75
19.1
1.99
50.4
ACROSS FLATS
TORQUE:
290 to 300 ft-lbs
394 to 420 Nm
ORIFICE DISC CANNOT BE USED
WITH THIS VALVE
due to HyPerformance™ cavity.
0.344 (8.74mm)
Dia. Mounting
Holes (2)
U.S. Patent 6,554,014
Cartridge: Weight: 2.0 kg. (4.5 lbs.)
Steel with hardened work surfaces.
Zinc-plated exposed surfaces.
Urethane seals without back-up rings
standard.
Ported Body: Weight: 16.61 kg.
(36.62 lbs.) HyPerformance™ ductile
iron (code 'D') standard. Rated to
345 bar (5000 psi). See page 8.042.1
MATERIALS TO ORDER
HPE42-S67K - __ - __
Seals
*U PPDI Urethane
*Urethane seals recommended for operating
pressures above 241 bar (3500 psi)
NOTE: Consult factory for additional seal
options,.
Porting
Cartridge Only 0
SAE 20 20TD
*1-1/4 in. BSP 10BD
*BSP Body; U.K. Mfr. Only
®
HYDRAFORCE
HYDRAFORCE
.com
®
Pilot Operated
Blue rectangles are links to other catalog pages.