DIRECTIONAL VALVES
HPE42-S67H HyPerformance Proportional,
DESCRIPTION
A high pressure, screw-in, cartridge-style, proportional, spring-centered, pilot-operat-
ed spool-type hydraulic directional valve with neutral position bleed-to-tank.
OPERATION
When the HPE42-S67H is in neutral position inlet port 3 is blocked and ports 2, 4,
and 5 are communicating with each other. On remote pilot signal at 1 the spool shifts
proportionally to the applied pilot pressure to allow flow from 3 to 4 through a load
such as a hydraulic cylinder or motor, and then from 2 to 5, and to tank. Port 5 is to
be used as tank port only with maximum pressure of 69 bar (1000 psi). On remote
pilot signal at port 6, the spool shifts proportionally to the applied force in the opposite
direction, thus reversing the flow direction.
The spool is symmetrical and provides meter-in and meter-out control.
FEATURES
Hardened spool and cage for long life.
Cost-effective cavity.
Excellent metering characteristics.
Good linearity.
All HyPerformance™ products are tested to the rigorous standards of the NFPA
specification T2.6.1 and are tested at a verification level of 90% and an assurance
of 99%.
RATINGS
Maximum Operating Pressure: Ports 2, 3, 4 (work): 350 bar (5075 psi)
(10% life cycle) 420 bar (6090 psi); Ports 1 and 6 (pilot): 35 bar (500 psi);
Port 5 (tank): 69 bar (1000 psi)
Flow Rating: 170 lpm (45 gpm)
Internal Leakage: 1310 ml/minute (80 cu. in./minute) at 350 bar (5075 psi)
Temperature: -54°C to 107°C (-65°F to 225°F) with urethane seals
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: HVC42-S6, Variation A; See page 9.142.1
Cavity Tool: HCT42-S6; See page 8.600.1
Seal Kit: HSK42-S6U-0000; See page 8.650.1
ISO SYMBOL
4.432.3
PERFORMANCE (Cartridge Only)
20.7/300
17.2/250
6.9/100
3.4/50
13.8/200
10.3/150
57
15
95
25
19
5
132
35
170
45
FLOW lpm/gpm
PRESSURE DROP bar/psi
Pressure Drop vs. Flow (Piloted)
2 to 5 - - - -; 3 to 4 – – –
3 to 2 and 4 to 5 ——
32 cSt/150 sus oil at 40°C
Flow vs. Pilot Pressure
3 to 4, Port 1 Pilot ——
3 to 2, Port 6 Pilot - - - -
32 cSt/150 sus oil at 40°C
37.9/10
18.9/5
56.8/15
75.5/20
94.6/25
113.6/30
151.4/40
132.5/35
170.3/45
0 6.9
100
6.9
100
13.8
200
13.8
200
20.7
300
20.7
300
PILOT PRESSURE bar/psi
FLOW lpm/gpm
U.S. Patent
6,554,014
HYDRAFORCE
.com
®
Blue rectangles are links to other catalog pages.
DIMENSIONS
MATERIALS TO ORDER
HPE42-S67H
4.432.4
6.14
155.9
3.56
90.4
INCH
MILLIMETRE
0.50
12.7
2.15
54.7
4.75
120.7
8.25
209.6
3.45
87.7
6.05
153.7
0.59
15.1
2.72
69.1
2.50
57.2
5.00
114.3
2.00
38.1
4.00
76.2
0.50
12.7
M42 x 2 – 6g
0.75
19.1
0.75
19.1
1.99
50.4
ACROSS FLATS
TORQUE:
290 to 300 ft-lbs
394 to 420 Nm
ORIFICE DISC CANNOT BE USED
WITH THIS VALVE
due to HyPerformance™ cavity.
0.344 (8.74mm)
Dia. Mounting
Holes (2)
U.S. Patent 6,554,014
Cartridge: Weight: 2.0 kg. (4.5 lbs.)
Steel with hardened work surfaces.
Zinc-plated exposed surfaces.
Urethone seals without back-up rings
standard.
Ported Body: Weight: 16.61 kg.
(36.62 lbs.) HyPerformance ductile
iron (code 'D') standard. Rated to
345 bar (5000 psi). See page 8.042.1
HPE42-S67H - __ - __
Seals
*U PPDI Urethane (standard)
*Urethane seals recommended for operating
pressures above 241 bar (5000 psi).
NOTE: Consult factory for additional seal options.
Porting
Cartridge Only 0
SAE 12 12TD
SAE 16 16TD
SAE 20 20TD
*3/4 in. BSP 6BD
*1 in. BSP 8BD
*1-1/4 in. BSP 10BD
*BSP Body; U.K. Mfr. Only
®