DIRECTIONAL VALVES
CV08-20 Check Valve
DESCRIPTION
A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding
device.
OPERATION
The CV08-20 allows fl ow passage from ➀ to ➁, while normally blocking oil fl ow in the
opposite direction.
The cartridge has a fully guided check which is spring-biased closed until suffi cient
pressure is applied at
➀ to open to ➁.
FEATURES
• Hardened seat for long life and low leakage.
• Optional bias springs for back-pressure application fl exibility.
• Fully guided check assembly.
• Compact size.
• Fast closing and seating.
RATINGS
Operating Pressure: 240 bar (3500 psi)
Proof Pressure: 350 bar (5075 psi)
Flow: See Performance Chart
Internal Leakage: 0.10 cc/minute (2 drops/minute) max. at 240 bar (3500 psi)
Crack Pressure Defi ned: Gauge psi evident at
➀ at 16.4 cc/minute (1 cu. in./minute)
attained
Standard Bias Springs at Crack: 0.3 bar (4 psi); 0.7 bar (10 psi); 1.7 bar (25 psi);
4.1 bar (60 psi)
Temperature: -40 to 120°C
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC08-2; See page 9.108.1
Cavity Tool: CT08-2XX; See page 8.600.1
Seal Kit: SK08-2X-T; See page 8.650.1
ISO:USASI:
PERFORMANCE (Cartridge Only)
SYMBOLS
4.010.1
6.9/100
5.2/75
3.4/50
1.7/25
7.5
2
15.1
4
22.7
6
30.2
8
FLOW lpm/gpm
PRESSURE DROP bar/psi
to
(with 0.7 bar/10 psi spring)
32 cSt/150 ssu oil at 40°C
➀➁
HYDRAFORCE
.com
®