EHPR98-G38 Proportional Reducing/Relieving
ISO SYMBOL
2.974.1
PERFORMANCE
% of MAX CONTROL CURRENT amps
PRESSURE bar/psi
Reducing Pressure vs. Current
12V Coil 100 Hz PWM
Reduced Pressure Port 2
G38C G38B G38A
6.9/100
13.8/200
20.7/300
20 40 60 10080
3.4/50
10.3/150
17.2/250
24.1/350
27.6/400
31.0/450
34.5/500
FLOW lpm/gpm
Pressure Drop vs. Flow
Cartridge Only
1 to 3 ; 2 to 1
3.4/50
6.9/100
10.3/150
13.8/200
17.2/250
7.6
2.0
15.1
4.0
22.7
6.0
30.2
8.0
20.7/300
2
3
DESCRIPTION
A direct-acting, spool-type, proportional, pressure reducing/relieving valve. It is a third
generation HydraForce drop-in, flange-mounted cartridge-type valve for use with
mineral-based or synthetic (with lubricating properties) hydraulic fluids. The coil is an
integral part of the valve and cannot be replaced or field-serviced. The regulated pres-
sure is proportional to the input electrical current in the pressure ranges shown.
OPERATION
The EHPR98-G38 allows free flow from 1 to 3 when no current is applied to the coil.
When the coil is energized, 2 is connected to 1. Increasing current applied to the coil
will increase the control (reduced) pressure proportionally. If pressure at 1 exceeds the
setting induced by the coil, pressure from 1 is relieved to 3.
FEATURES
• Economical drop-in style. • Quick response time.
•
Mounting plate option. • Screen option.
•
Several regulated pressure ranges. • Top-mounted connector.
•
Retrofit option for EHPR98-T38. • Low leakage.
RATINGS
Pressure Rating: 34.5 bar (500 psi) at all ports
Proof Pressure: Ports 1 and 2: 207 bar (3000 psi) Port 3: 54 bar (780 psi)
Burst Pressure: 45 bar (652 psi) all ports pressurized
Flow Rating: 23 lpm (6 gpm)
Maximum Internal Leakage: De-energized: 50 ml/min (3.1 cu. in./min) @ 34.5 bar
(500 psi); Energized @ Imax: To be determined
Cycle Life: 10 million cycles
Operating Fluid Temperature: -40 to 149°C (-40 to 300°F), with standard HNBR
seals; -26 to 204°C (-15 to 400°F), with fluorocarbon seals
Maximum Control Current: 1.0 amps for 10 VDC coil; 0.88 amps for 12 VDC coil;
0.72 amps for 14 VDC coil; 0.52 amps for 20 VDC coil ; 0.44 amps for 24 VDC coil;
0.36 amps for 28 VDC coil.
Control Pressure at Maximum Control Current: 21 bar (305 psi) for EHPR98-
G38A; 25 bar (363 psi) for EHPR98-G38B; 30 bar (435 psi) for EHPR98-G38C
Hysteresis: 4% with 120 Hz PWM
Resistance: 4.8 ohm (10V), 7.2 ohm (12V), 10.0 ohm (14V), 18.3 ohm (20V);
29.5 ohm (24V), 40.3 ohms (28V)
Inductance: 77 mH (10V), 118 mH (12V), 165 mH (14V), 301 mH (20V), 446 mH
(24V), 680 mH (28V)
Environmental Rating: IP69K; 1000-hour salt spray per ASTM B117
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: Flange Mounted. See page 8.525.1
Cavity: VC-G028 (Standard Configuration); VC-T011 (Retrofit Application);
See page 9.111.1
Cavity Tools: CT-G028 (Standard Configuration); CT-T011 (Retrofit Application);
See page 8.600.1
Seal Kit: SK-G028-X; See page 8.650.1
®
ELECTRO-PROPORTIONAL VALVES--PRESSURE CONTROLS
HYDRAFORCE
.com
®