EHPR98-T38 Proportional Reducing/Relieving
ISO SYMBOL
2.973.1
PERFORMANCE
DESCRIPTION
A direct-acting, spool-type, drop-in-style, flange-mounted, pressure reducing/reliev-
ing valve, which can be infinitely adjusted across a prescribed range using a variable
electric input. Pressure output is proportional to DC current input. The E-coil is an
integral part of the valve assembly, and cannot be replaced or field-serviced.
OPERATION
The EHPR98-T38 allows free flow from 1 to 3 when no current is applied to the coil.
When the coil is energized, 2 is connected to 1. Increasing current applied to the coil
will increase the control (reduced) pressure proportionally. If pressure at 1 exceeds
the setting induced by the coil, pressure from 1 is relieved to 3.
Note: Back pressure on port 3 becomes additive to the pressure setting at a 1:1 ratio.
Note: Operation of manual override option: Rotate manual override screw clockwise
until desired regulated pressure is achieved.
FEATURES
• Economical drop-in style. • 1000-hour salt spray protection.
• Integral waterproof coil standard. • Optional 142 micron screen at port 2.
RATINGS
Pressure Rating: 241 bar (3500 psi)
Tank Port (3) Pressure: 34.5 bar (500 psi) maximum;
17.2 bar (250 psi) maximum with manual override option.
Maximum Control Current: 1.38 amps for 10 VDC coil; 1.30 amps for 12 VDC coil;
0.69 amps for 20 VDC coil; 0.65 amps for 24 VDC coil
Control Pressure at Maximum Control Current: 30 bar (435 psi)
Resistance: 4.3 ohm (10V); 5.2 ohm (12V); 17.5 ohm (20V); 20.9 ohm (24V)
Inductance: 80 mH (12V)
Hysteresis: at 100 Hz PWM: 5% of maximum control pressure
Flow Rating: 18.9 lpm (5.0 gpm)
Maximum Internal Leakage: De-engergized: 50 ml/min. (3 cu. in./min.) at 34.5 bar
(500 psi); Energized at I-max: 100 ml/min. (6 cu. in./min.) at 34.5 bar (500 psi)
Temperature: -40° to 149°C (-40° to 300°F) with HNBR seals; -26° to 204°C
(-15° to 400°F) with fluorocarbon seals
Ambient Air Temperature: -40° to 80°C (-40 to 176°F)
Environmental Rating: IP69K
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Mounting Screws: M4 x 0.7 x 12 Long; Part No. 4001015 (not provided with valve)
Cavity: VC-T011; See page 9.111.1
Cavity Tool: CT-T011R0-x-G; See page 8.600.1
Seal Kit: SK-T011; See page 8.650.1
ELECTRO-PROPORTIONAL VALVES—PRESSURE CONTROLS
HYDRAFORCE
.com
®
FLOW l
m/
m
PRESSURE bar/psi
Pressure Drop vs. Flow
Cartridge Only
1 to 3 ———; 2 to 1 - - - - -
1.7/25
3.4/50
5.2/75
6.9/100
8.6/125
3.8
1.0
7.6
2.0
11.4
3.0
15.1
4.0
18.9
5.0
Relieving Pressure 1 to 3
Typical Relieving/Reducing Pressure vs. Flow Characteristic
Typical Relieving Pressure at Various %s of Maximum Control Current
Inlet: 34.5 bar/500 psi ——; Inlet 241 bar/3500 psi – – –
(Curves overlap on Relieving Pressure side of graph); 150 Hz PWM (Both Directions)
FLOW lpm/gpm
15.1
4.0
15.1
4.0
18.9
5.0
18.9
5.0
11.4
3.0
11.4
3.0
7.6
2.0
7.6
2.0
3.8
1.0
3.8
1.0
0
Reducing Pressure 2 to 1
100% Max. Control Current
75% Max. Control Current
30% Max. Control Current
0% Max. Control Current
60% Max. Control Current
% of MAXIMUM RELIEF PRESSURE
% of MAXIMUM REDUCING PRESSURE
50
0
25
75
100
125
150
50
25
75
100
125
150
0
45% Max. Control Current
CURRENT amps
PRESSURE bar/psi
Reducing Pressure vs. Current
6.9/100
13.8/200
20.7/300
27.6/400
34.5/500
0.2 0.4 0.6 1.00.8 1.41.2
Reducing Pressure 2 to 1
Inlet: 34.5 bar/500 psi; 150 Hz PWM; 12V Coil
Blue rectangles are links to other catalog pages.