EHPR98-T35 Proportional Reducing/Relieving
USASI/ISO:
SYMBOLS
2.972.1
PERFORMANCE
CURRENT amps
PRESSURE bar/psi
Reducing Pressure vs. Current
Inlet: 25 bar/365 psi; 100 Hz PWM
Reduced Pressure to ~
2.8/40
5.5/80
8.3/120
11.0/160
13.8/200
16.5/240
19.3/280
22.1/320
0.2 0.4 0.6 1.00.8 1.41.2
FLOW lpm/gpm
PRESSURE bar/psi
Pressure Drop vs. Flow
Cartridge Only
1 to 3 —— ; 2 to 1 - - - -
1.7/25
3.4/50
5.2/75
6.9/100
8.6/125
10.3/150
12.1/175
0.9
0.25
1.9
0.50
2.8
0.75
3.8
1.00
4.7
1.25
5.7
1.50
DESCRIPTION
A direct-acting, spool-type, drop-in-style, fl ange-mounted, pressure reducing/reliev-
ing valve, which can be infi nitely adjusted across a prescribed range using a variable
electric input. Pressure output is proportional to DC current input. The Ecoil is an
integral part of the valve assembly, and cannot be replaced or fi eld-serviced.
OPERATION
The EHPR98-T35 allows free fl ow from ➀ to ➂ when no current is applied to the coil.
When the coil is energized,
➁ is connected to ➀. Increasing current applied to the coil
will increase the control (reduced) pressure proportionally. If pressure at
➀ exceeds
the setting induced by the coil, pressure from
➀ is relieved to ➂.
Note: Back pressure on port
➂ becomes additive to the pressure setting at a 1:1 ratio.
FEATURES
• Economical drop-in style. • Several push-on termination options.
• Integral waterproof coil standard. • 1000-hour salt spray protection.
• 10, 12, 20 or 24 VDC coils.
RATINGS
Maximum Inlet Pressure: 103 bar (1500 psi); If higher inlet pressure is required
(103 bar/1500 psi to 241 bar/3500 psi) select the “A” option in the model code.
Maximum Tank Pressure: 34.5 bar (500 psi);
with Manual Override Option: 17.2 bar (250 psi)
Control Pressure at Maximum Control Current: 20.7 bar (300 psi)
Maximum Control Current: 1.38 amps for 10 VDC coil; 1.30 amps for 12 VDC coil;
0.69 amps for 20 VDC coil; 0.65 amps for 24 VDC coil
Resistance: 4.2Ω (10V); 5.1Ω (12V); 17.0Ω (20V); 19.3Ω (24V)
Inductance: 80 mH (12V); Hysteresis: Less than 4% with 100 Hz PWM
Flow Rating: 5.7 lpm (1.5 gpm)
Maximum Internal Leakage:
De-energized: 75 ml/minute (4.58 cu. in./minute) at 25 bar (365 psi);
200 ml/minute (12.2 cu. in minute) at 241 bar (3500 psi).
Energized at I-Max.: 125 ml/minute (7.63 cu. in./minute) at 25 bar (365 psi);
400 ml/minute (24.4 cu. in. minute) at 241 bar (3500 psi)
Temperature: -40 to 120°C (-40 to 250°F), with standard Buna N seals
Ambient Air Temperature: -40 to 80°C (-40 to 176°F)
Environmental Rating: IP69K
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: Flange Mount
Mounting Screws: M4 x 0.7 x 12 Long; Part No. 4001015 (not provided with valve)
Cavity: VC-T009; See page 9.111.1; Cavity Tool: CT-T009R0-x-G; See page 8.600.1
Seal Kit: SKEHPR98-T3X; See page 8.650.1
ELECTRO-PROPORTIONAL VALVES—PRESSURE CONTROLS
Relieving Pressure ➀ to ➂
Typical Relieving/Reducing Pressure vs. Flow Characteristic
Inlet: 25 bar/365 psi ——— ; Inlet: 241 bar/3500 psi - - - - -
100 Hz PWM (Both Directions); Note: Curves overlap on Relieving Pressure (LH) side of graph
FLOW lpm/gpm
3.8
1.00
4.7
1.25
5.7
1.50
2.8
0.75
1.9
0.50
0.9
0.25
0 0.9
0.25
1.9
0.50
2.8
0.75
3.8
1.00
4.7
1.25
5.7
1.50
Reducing Pressure ➁ to ➀
0 mA
RELIEF PRESSURE bar/psi
REDUCING PRESSURE bar/psi
6.9/100
0
3.4/50
10.3/150
24.1/350
27.6/400
0
20.7/300
17.2/250
13.8/200
6.9/100
3.4/50
10.3/150
24.1/350
27.6/400
20.7/300
17.2/250
13.8/200
1300 mA
1000 mA
800 mA
600 mA
400 mA
HYDRAFORCE
.com
®