EHPR98-T33 Proportional Reducing/Relieving
USASI/ISO:
SYMBOLS
2.971.1
PERFORMANCE
CURRENT amps
PRESSURE bar/psi
Reducing Pressure vs. Current
Inlet: 241 bar/3500 psi; 100 Hz PWM
Reducing Pressure ➁ to ➀
6.9/100
13.8/200
20.7/300
27.6/400
34.5/500
0.2 0.4 0.6 1.00.8 1.41.2
FLOW lpm/gpm
PRESSURE bar/psi
Pressure Drop vs. Flow
Cartridge Only
1 to 3 —— ; 2 to 1 - - - -
1.7/25
3.4/50
5.2/75
6.9/100
8.6/125
0.8
0.2
1.5
0.4
2.3
0.6
3.0
0.8
3.8
1.0
DESCRIPTION
A direct-acting, spool-type, drop-in-style, fl ange-mounted, pressure reducing/reliev-
ing valve, which can be infi nitely adjusted across a prescribed range using a variable
electric input. Pressure output is proportional to DC current input. The Ecoil is an
integral part of the valve assembly, and cannot be replaced or fi eld-serviced.
OPERATION
The EHPR98-T33 allows free fl ow from ➀ to ➂ when no current is applied to the coil.
When the coil is energized,
➁ is connected to ➀. Increasing current applied to the coil
will increase the control (reduced) pressure proportionally. If pressure at
➀ exceeds
the setting induced by the coil, pressure from
➀ is relieved to ➂.
Note: Back pressure on port
➂ becomes additive to the pressure setting at a 1:1 ratio.
FEATURES
• Economical drop-in style. • Integral waterproof coil standard.
• 1000-hour salt spray protection. • 10, 12, 20 or 24 VDC coils.
• Several push-on termination options.
RATINGS
Maximum Inlet Pressure: 241 bar (3500 psi)
Common Port Burst Pressure: One cycle at 158 bar (2300 psi) on all ports
simultaneously pressurized
Tank Port (
➂) Pressure: 34.5 bar (500 psi) maximum for 100,000 cycles
Maximum Control Current: 1.38 amps for 10 VDC coil; 1.30 amps for 12 VDC coil;
0.69 amps for 20 VDC coil; 0.65 amps for 24 VDC coil
Resistance: 4.2 ohm (10V), 5.1 ohm (12V), 17.0 ohm (20V), 19.3 ohm (24V)
Inductance: 80 mH (12V)
Hysteresis: Less than 3% with 100 Hz PWM
Flow Rating: 3.8 lpm (1.0 gpm)
Step Response: T
ON <30 ms; TOFF <12 ms
Temperature: -40 to 149°C (-40 to 300°F) with HNBR seals
-26 to 204°C (-15 to 400°F) with Fluorocarbon seals
-54 to 107°C (-65 to 225°F) with Polyurethane seals
Ambient Air Temperature: -40 to 80°C (-40 to 176°F)
Environmental Rating: IP69K
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: Flange Mount
Mounting Screws: M4 x 0.7 x 12 Long; Part No. 4001015 (not provided with valve)
Cavity: VC-T009; See page 9.111.1; Cavity Tool: CT-T009R0-x-G; See page 8.600.1
Seal Kit: SKEHPR98-T3X; See page 8.650.1
ELECTRO-PROPORTIONAL VALVES—PRESSURE CONTROLS
Relieving Pressure ➀ to ➂
Typical Relieving/Reducing Pressure vs. Flow Characteristic
Typical Relieving Pressure at Various %s of Maximum Control Current
Inlet: 241 bar/3500 psi; 100 Hz PWM (Both Directions)
FLOW lpm/gpm
3.8
1.00
2.8
0.75
1.9
0.50
0.9
0.25
0 0.9
0.25
1.9
0.50
2.8
0.75
3.8
1.00
Reducing Pressure ➁ to ➀
100% Max. Control Current
75% Max. Control Current
50% Max. Control Current
25% Max. Control Current
0% Max. Control Current
% of MAXIMUM RELIEF PRESSURE
% of MAXIMUM REDUCING PRESSURE
50
0
25
75
100
125
50
0
25
75
100
125
HYDRAFORCE
.com
®
Blue rectangles are links to other catalog pages.