TS10-27 Proportional Pressure Relief Valve with
ISO SYMBOL
2.862.1
PERFORMANCE
FLOW (lpm/gpm)
PRESSURE (bar/psi)
Pressure Drop vs. Flow Characteristic
For Flow 1 to 2 with Coil Energized
0
0
3.4/50
6.9/100
10.3/150
13.8/200
17.2/250
20.7/300
24.1/350
27.6/400
18.9/5 37.8/10 56.8/15 75.7/20 94.6/25
Cartridge & Body
Body Only
Relief Pressure vs. Current (DC) Characteristic
Relieving Pressure 1 to 2;
With Constant Flow 7.6 lpm/2gpm
PRESSURE (bar/psi)
0
34.5/500
68.9/1000
103.4/1500
137.9/2000
172.4/2500
% of Maximum Control Current
02010 30 50 70 9040 60 80 100
A
B
C
206.8/3000
241.3/3500
DESCRIPTION
A screw-in, cartridge-style, pilot-operated, spool-type hydraulic relief valve, which can
be infinitely adjusted across a prescribed range using a variable electric input.
Pressure output is inversely proportional to DC current input. This valve is intended
for use as a pressure-limiting device in demanding applications.
OPERATION
The TS10-27 blocks flow from 1 to 2 until sufficient pressure is present at 1 to open
the valve by overcoming the preset induced spring force. With no current applied,
the valve will relieve at ±50 psi of the range maximum. Applying current to the coil
decreases the induced spring force, thereby reducing the valve setting.
Note: This valve is ideal for hydraulic fan drive applications. Consult factory for
electronic controllers specifically designed for fan drive applications.
FEATURES
• 12 and 24 volt coils standard.
• Industry common cavity.
• Adjustable or fixed relief pressure settings.
• Higher pressure 330.9 bar (4800 psi) factory-set model F available.
RATINGS
Pressure Rating: 275.8 bar (4000 psi) at Port 1;TS10-27F 330.0 bar (4800 psi)
Proof Pressure: 344.7 bar (5000 psi) at Port 1; 206.8 bar (3000 psi) at Port 2;
TS10-27F 413.7 bar (6000 psi) at Port 1 and 206.8 bar (3000 psi) at Port 2
Burst Pressure: 814 bar (11,800 psi) at all ports
Electrical Parameters:
Coil *Typical Max. Current
(A) at 0 gpm
Typical Resistance
± 5% @ 20°C (ohms)
Typical Apparent
Inductance (mH)
12 VDC 24 VDC 12 VDC 24 VDC 12 VDC 24 VDC
D-Coil 1.10 0.55 6.7 ±5% 25 ±5% 134 mH 500 mH
E-Coi
l
1.20 0.55 7.32 ±5% 29.3 ±5% 139 mH 560 mH
Relief Pressure Range from Zero to Maximum Control Current:
A: 206.8–6.9 bar (3000–100 psi) B: 138–6.9 bar (2000–100 psi)
C: 69–6.9 bar (1000–100 psi) F: Factory Set: 275.8–55.2 bar (4000–800 psi)
*Consult factory for detailed current range for particular pressure setting.
Note: Tank port pressure is additive to valve setting.
Rated Flow: 75.7 lpm (20 gpm), P = 20.7 to 24.1 bar (300 to 350 psi), cartridge
only, 1 to 2 coil energized
Hysteresis (PMW 200 Hz): A: 3.2%; B: 3.0%; C: 4.8% F: 4%
Pressure Rise: A: 0.48 bar/lpm (26.5 psi/gpm); B: 0.36 bar/lpm (20 psi/gpm);
C: 0.46 bar/lpm (25 psi/gpm) F: 1.86 bar/lpm (27 psi/gpm)
Operating Fluid Temperature: -40 to 100°C (-40 to 212°F) with standard Buna N
seals; -26 to 204°C (-15 to 400°F) with fluorocarbon seals; -54 to 107°C (-65 to
225°F) with polyurethane seals.
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation Recommendation: When possible, the valve should be mounted below
the reservoir oil level. This will maintain oil in the armature preventing trapped air
instability. If this is not feasible, mount the valve horizontally for best results.
Cavity: VC10-2; See page 9.110.1
Cavity Tool: CT10-2XX; See page 8.600.1
Seal Kit: SK10-2X-B; See page 8.650.1
Coil Nut: Part No. 4540550;
For E-coils manufactured prior to 1-1-04, see page 3.400.1 for coil nut info.
U.S. Patents
6,267,350
&
7,137,406
ELECTRO-PROPORTIONAL VALVES—PRESSURE CONTROLS
HYDRAFORCE
.com
®
TS10-27F Relief Pressure vs. Current (DC)
Relieving Pressure 1 to 2;
With Constant Flow 7.6 lpm/2 gpm
PRESSURE (bar/psi)
0
68.9/1000
137.9/2000
206.8/3000
% of Maximum Control Current
02010 30 50 70 9040 60 80 100 110
275.8/4000
344.7/5000
Lower Pressure Range
Higher Pressure Range
Blue rectangles are links to other catalog pages.