TS08-27 Proportional Electrohydraulic Relief Valve
DESCRIPTION
A screw-in, cartridge-style, pilot-operated, spool-type proportional electrohydraulic
pressure relief valve, which can be infinitely adjusted across a prescribed range using
a variable electric input. Pressure output is inversely proportional to DC current input.
This valve is intended for use as a pressure limiting device in demanding applications.
OPERATION
The TS08-27 blocks flow from 1 to 2 until sufficient pressure is present at 1 to open
the valve by overcoming the preset induced spring force. With no current applied,
the valve will relieve at ±50 psi of the spring maximum. Applying current to the coil
reduces the induced spring force thereby reducing the valve setting. The regulated
pressure is inversely proportional to the input electrical current.
Note: This valve is ideal for hydraulic fan drive applications. Consult factory for
electronic controllers specifically designed for fan drive applications.
FEATURES
• 12 and 24 volt coils standard. • Industry common cavity.
• Hardened parts for long life.
RATINGS
Maximum Operating Pressure: 241 bar (3500 psi)
Electrical Parameters:
D-Coil E-Coil
10 VDC 12 VDC 20 VDC 24 VDC 12 VDC 24 VDC
Max Control Current
(amperes)
1.50 1.31 0.85 0.65 1.40 0.70
Resistance (Nominal)
(ohms)
3.1 5.4 12.2 21.7 5.4 21.7
Relief Pressure Range from Zero to Maximum Control Current: A: 207–6.9 bar
(3000–100 psi) B: 138–6.9 bar (2000–100 psi) C: 68.9–6.9 bar (1000–100 psi)
Rated Flow: 24.6 lpm/6.5 gpm; P = 13.8-17.2 bar (200-250 psi), cartridge only;
port 1 to 2 coil energized
Maximum Pilot Flow: 0.76 lpm (0.2 gpm)
Hysteresis at PWM 200 Hz (% of max pressure): A: 3.2 B: 3.0 C: 4.8
Flow Path: Free Flow: 1 to 2 coil energized; Relieving: 1 to 2 coil de-energized
Pressure Rise: A: 0.48 bar/lpm (26.5 psi/gpm(; B: 0.36 bar/lpm (20 psi/gpm)
C: 0.46 bar/lpm (25 psi/gpm)
Temperature: -40 to 120°C (-40 to 250°F) with standard Buna N seals
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation Recommendation: When possible, the valve should be mounted below
the reservoir oil level. This will maintain oil in the armature preventing trapped air
instability. If this is not feasible, mount the valve horizontally for best results.
Cavity: VC08-2; See page 9.108.1; Cavity Tool: CT08-2XX; See page 8.600.1
Seal Kit: SK08-2X-B; See page 8.650.1
ISO SYMBOL
2.860.1
PERFORMANCE
ELECTRO-PROPORTIONAL VALVES—PRESSURE CONTROLS
U.S.
Patents
6,267,350
&
7,137,406
TYPICAL RELIEF PRESSURE VS. FLOW CHARACTERISTIC
Typical Relieving Pressure Port 1 to Port 2 at No Current Applied
With Constant Flow 7.1 lpm/2 gpm; Cartridge in Body
FLOW (LPM/GPM)
7.6/
2.0
11.4/
3.0
15.1/
4.0
18.9/
5.0
22.7/
6.0
26.5/
7.0
3.8/
1.0
PRESSURE (BAR/PSI)
27.6/400
55.1/800
82.7/1200
110.3/1600
137.9/2000
165.5/2400
193.0/2800
220.6/3200
248.2/3600
0
0
Range A
Range B
Range C
PRESSURE DROP VS. FLOW CHARACTERISTIC
Flow from Port 1 to Port 2 with Coil Energized,
at Maximum Set Current
PRESSURE (BAR)
PRESSURE (PSI)
FLOW (GPM)
FLOW (LPM)
0 2.0 3.0 4.0 5.0 6.0 7.01.0
0 3.8 7.6 11.4 15.1 18.9 22.7 26.5
25
50
75
100
125
150
175
200
225
1.7
3.4
5.2
6.9
8.6
10.3
0
0
12.1
13.8
15.5
Cartridge, Body & Line
Body & Line
HYDRAFORCE
.com
®
Blue rectangles are links to other catalog pages.