ELECTRO-PROPORTIONAL VALVES—PRESSURE CONTROLS
TS10-26 Proportional Electric Relief w/Internally
USASI/ISO:
SYMBOLS
2.852.1
PERFORMANCE
FLOW (gpm)
FLOW (lpm)
PRESSURE (bar)
PRESSURE (psi)
Pressure Drop vs. Flow Characteristic
For Flow to with Coil De-energized
0 5 10 15 20 25
0
00
50
100
150
200
250
2
4
6
8
10
12
14
16
18
20
20 40 60 80 100
Cartridge & Body
Cartridge Only
Body Only
Relief Pressure vs.
Current (DC) Characteristic
200 Hz PWM
Relieving Pressure to
PRESSURE (psi)
0
500
1000
1500
2000
2500
3000
3500
PRESSURE (bar)
0
50
100
150
200
250
% of Maximum Control Current
02010 30 50 70 9040 60 80 100
A
B
C
Typical Relief Pressure
vs. Flow Characteristic
Typical Relieving Pressure to
at Various %’s of Maximum Control Current
Pressure Range “A” (207 bar/3000 psi); Cartridge in Body
FLOW (gpm)
0 5 10 15 20 25
% of MAXIMUM RELIEF PRESSURE
50
0
25
75
100
125
% of MAXIMUM RELIEF PRESSURE
50
0
25
75
100
125
FLOW (lpm)
0 20 40 60 80 100
50% Max. Control C
urrent
75% Max. Control Current
100% Max. Control Current
25% Max. Control Current
DESCRIPTION
A screw-in, cartridge-style, pilot-operated, spool-type hydraulic relief valve, which can
be infi nitely adjusted across a prescribed range using a variable electric input.
Pressure output is proportional to DC current input. This valve is intended for use as
a pressure limiting device in demanding applications.
OPERATION
The TS10-26 blocks fl ow from to until suffi cient pressure is present at to open
the pilot section by offsetting the electrically induced solenoid force. With no current
applied to the solenoid, the valve will relieve at approximately 100 psi.
The optional manual override allows the valve to be set when the electric supply is
lost. The manual setting is added to the electric setting. To prevent the system from
being over pressurized, the manual override should always be disengaged prior to
applying power to the coil.
FEATURES
Optional Manual Override.
Optional waterproof E-Coils rated up to IP69K.
12 and 24 volt coils standard.
Industry common cavity.
RATINGS
Maximum Operating Pressure: 241 bar (3500 psi)
Maximum Control Current: 1.10 amps for 12 VDC coil; 0.55 amps for 24 VDC coil
Relief Pressure Range from Zero to Maximum Control Current:
A: 6.9–207 bar (100–3000 psi) C: 6.9–117 bar (100–1700 psi)
B: 6.9–159 bar (100–2300 psi)
Rated Flow: 94.6 lpm (25 gpm), ΔP=13.1 bar (190 psi), Cartridge only,
to coil de-energized
Maximum Pilot Flow: 0.76 lpm (0.2 gpm)
Hysteresis: Less than 3%
Flow Path: Free Flow:
to coil de-energized; Relieving: to coil energized
Temperature: -40 to 100°C (-40 to 212°F) with standard Buna N seals
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation Recommendation: When possible, the valve should be mounted below
the reservoir oil level. This will maintain oil in the armature preventing trapped air
instability. If this is not feasible, mount the valve horizontally for best results.
Cavity: VC10-2; See page 9.110.1; Cavity Tool: CT10-2XX; See page 8.600.1
Seal Kit: SK10-2N-B; See page 8.650.1
Coil Nut: Part No. 4540560;
For E-coils manufactured prior to 1-1-04, see page 3.400.1 for coil nut info.
Patent
Pending
HYDRAFORCE
.com
®
Recommended Electronic Controllers:
Model EFDR2 Multi-Input Fan Drive Controller.
For more information go to:
http://www.hydraforce.com/Electro/fandrive.htm
or
Recommended Electronic Controllers
catalog page 2.001.1 (Table 2)
Blue rectangles are links to other catalog pages.
MATERIALS
Cartridge: Weight: 0.25 kg. (0.55 lbs.)
Steel with hardened work surfaces.
Zinc-plated exposed surfaces. Buna N
O-rings and polyester elastomer back-
ups standard. Optional polyurethane
seals with fl uorocarbon back-up
recommended for pressures over
240 bar (3500 psi).
Standard Ported Body: Weight: 0.16 kg.
(0.35 lbs.) Anodized high-strength 6061
T6 aluminum alloy, rated to 207 bar
(3000 psi). Ductile iron bodies available;
dimensions may differ. See page 8.010.1
Standard Coil: Weight: 0.32 kg. (0.7 lbs.)
Unitized, thermoplastic encapsulated,
Class H high temperature magnetwire.
See page 3.200.1
E-Coil: Weight: 0.41 kg. (0.9 lbs.) Fully
encapsulated with rugged external metal
shell. Rated up to IP69K with integral
connectors. Note: See page 3.400.1 for
all E-Coil retrofi t applications.
TO ORDER
TS10-26
2.852.2
Piloted Spool
1.48
37.6
3.01
76.5
1.25
31.8
0.75
19.1
0.28
7.1
1.63
41.4
0.13
3.3
2.00
50.8*
*BSP BODY
55.9 mm
1.50
38.1
1.25
31.8
INCH
MILLIMETRE
1.25
31.8
ACROSS FLATS
TORQUE
25 ft-lbs
(33.9 Nm) max.
MANUAL
OVERRIDE
(3/16" HEX)
1.73
44.0
TORQUE
7–10 ft-lbs
(9.5–13.6 Nm) max.
INITIAL SETUP:
Before operating valve,
use the manual override
to manually set pressure
to 200 to 300 psi. Before
operating electrically,
back out manual override
(CCW using 3/16" hex key
wrench) until positive stop
is reached. Manual override
must be fully backed out
when operating electrically.
1.62
41.1
1.84
DIA.
46.7
E-Coil
View
Standard
Coil View
DIMENSIONS
TS10-26 __ __ - __ - __ - __ __ __ __
Porting
Cartridge Only 0
SAE 6 6T
SAE 8 8T
3/8 in. BSP* 3B
1/2 in. BSP* 4B
*BSP Body; U.K. Mfr. Only
Maximum
Relief Pressure
207 bar (3000 psi) A
159 bar (2300 psi) B
117 bar (1700 psi) C
Option
None
(Blank)
Manual Override M
Voltage
0 Less Coil
10 10 VDC (1.30 amps max.)
12 12 VDC (1.10 amps max.)
20 20 VDC (0.65 amps max.)
24 24 VDC (0.55 amps max.)
Coils with internal
diode are available.
Consult factory.
Termination Std. Coil
DS Dual Spades
DG DIN 43650
DL Leadwires (2)
DL/W Leads w/Weatherpak
®
Connectors
DR Deutsch DT04-2P
Termination E-Coil
ER Deutsch DT04-2P
(IP69K Rated)
EY Metri-Pack
® 150
(IP69K Rated)
Seals
Buna N (Std.) N
Fluorocarbon V
®
HYDRAFORCE
HYDRAFORCE
.com
®
Patent Pending
Blue rectangles are links to other catalog pages.