DESCRIPTION
A pressure-compensated electrically-variable three-port fl ow regulator that is a priority
(bypass) type control. This combination valve uses a PV70-33x proportional cartridge
and an EC12-40 compensator.
OPERATION
The PFR70-33x-J series will bypass all fl ow when de-energized at the pressure
compensator spring value. When energized, this proportional valve/compensator
package will regulate fl ow out of port
, regardless of system working pressure,
with an increasing current applied to the solenoid.
FEATURES
Excellent linearity and hysteresis.
Optional control orifi ce sizes.
Hardened spool and cage for long life.
Optional coil voltages and terminations.
Effi cient wet armature construction.
RATINGS
Operating Pressure: 207 bar (3000 psi)
Pressure Rise: Pressure at
begins to rise higher than the compensating pressure
differential when bypass fl ow exceeds 41.6 lpm (11 gpm).
Internal Leakage: 410 cc/min. (25 cu. in./min.) fully closed at 207 bar (3000 psi) out
port
.
Electrical: 2 standard voltage ratings
2.403.1
USASI/ISO:
SYMBOLS
PERFORMANCE CURVES
24 Volt coil used; 130 Hz dither; PWM controller
37.9/10
41.4
600
LOAD bar/psi
FLOW lpm/gpm
Priority Port Flow Rate Loss Under Load
PV70-33A with EC12-40 Typical
11 bar/160 psi compensator —
6.9 bar/100 psi compensator - - -
82.8
1200
124.1
1800
165.5
2400
206.9
3000
34.1/9
30.2/8
22.7/6
15.1/4
7.5/2
26.5/7
18.9/5
11.4/3
3.8/1
PFR70-33x-J Proportional Priority Flow Regulator,
37.9/10
CURRENT amp
FLOW lpm/gpm
Flow vs. Current (207 bar/3000 psi Load)
PV70-33B with EC12-40
11 bar/160 psi spring ——
6.9 bar/100 psi spring - - - -
100 Hz Dither
.1
34.1/9
22.7/6
18.9/5
11.4/3
3.8/1
7.5/2
15.1/4
26.5/7
30.2/8
.2 .3 .4 .5 .6 .7 .8 .9 1.0
37.9/10
CURRENT amp
FLOW lpm/gpm
Flow vs. Current (207 bar/3000 psi Load)
PV70-33C with EC12-40
11 bar/160 psi spring ——
6.9 bar/100 psi spring - - - -
100 Hz Dither
.1
34.1/9
22.7/6
18.9/5
11.4/3
3.8/1
7.5/2
15.1/4
26.5/7
30.2/8
.2 .3 .4 .5 .6 .7 .8 .9 1.0
Priority Port Flow Delivered Out Port :
37.9/10
CURRENT amp
FLOW lpm/gpm
Flow vs. Current (207 bar/3000 psi Load)
PV70-33A with EC12-40
11 bar/160 psi spring ——
6.9 bar/100 psi spring - - - -
100 Hz Dither
.1
34.1/9
22.7/6
18.9/5
11.4/3
3.8/1
7.5/2
15.1/4
26.5/7
30.2/8
.2 .3 .4 .5 .6 .7 .8 .9 1.0
Operation of Manual Override:
To Engage: Turn clockwise approximately 1 turn to reach start point. Continue
another approximately 5 turns to full shift.
To Disengage: Turn counterclockwise approximately 6 turns until positive stop
is found.
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1; Filtration: See page 9.010.1
For 12 volt coils, double the current (amp) values shown.
Attention Manifold Designers:
To obtain these high fl ow capabilities
using proportional fl ow controls and
compensators, optimized cavity drillings
are required. Please consult factory.
ELECTRO-PROPORTIONAL VALVES—FLOW CONTROLS
HYDRAFORCE
.com
®
Cartridges voltage interchangeable.
Unitized, molded coil design.
Coil waterproofi ng standard.
Screw-in manual override option.
Threshold
Current (mA)
A & B C
Range Range
300 ± 70 360 ± 70
150 ± 35 180 ± 35
Coil
Voltage
12 VDC
24 VDC
Max. Control
Current (mA)
A & B C
Range Range
1500 ± 200 1400 ± 200
750 ± 100 700 ± 100
Blue rectangles are links to other catalog pages.
DIMENSIONS
PFR70-33x-J
2.403.2
3-Port, Pressure Compensated
Ports 1 & 3: SAE 12
Port 2: SAE 10
®
HYDRAFORCE
HYDRAFORCE
.com
®
Cartridge: Steel with hardened
work surfaces. Zinc-plated
exposed surfaces.
Buna N O-rings and
back-ups standard.
Standard Ported Body:
Anodized high-strength
6061 T6 aluminum alloy,
rated to 207 bar (3000 psi).
Ductile iron bodies available;
dimensions may differ.
Consult factory.
Coil: D-Coil: See page 3.200.1
E-Coil: See page 3.400.1
Package Weight: 2.72 kg.
(6 lbs.)
Seal Kit: SK10-3x-MM (PV)
SK12-4x-TMB (EC)
MATERIALS TO ORDER
Override
Option
(Blank) None
M Screw Type
Voltage
0 Less Coil
12 12 VDC
24 24 VDC
*Compensator Spring
6.9 bar (100 psi) 100
11.03 bar (160 psi) 160
PFR70-33 __ - J __ - 10/12T - __ - __ __ __ __
NOTE: The normally
open PV70-35 may
not be substituted in
this manifold due
to port logic factors.
*Select Orifi ce Range and Compensator
Spring by referring to the Performance
Curves on the preceding page.
*PV Orifi ce Range
Orifi ce Range A
Orifi ce Range B
Orifi ce Range C
Coils with internal diode are
available. Consult factory.
Seals
Buna N (Std.) N
Fluorocarbon V
Terminations D-Coil
DS Dual Spades
DG DIN 43650
DL Leadwires (2)
DL/W Leads w/Weatherpak
®
Connectors
Terminations E-Coil
IP69K Rated
ER Deutsch DT04-2P
EY Metri-Pack
®
150
Blue rectangles are links to other catalog pages.