2.402.1
USASI/ISO:
SYMBOLS
PFR70-33x-F Proportional Priority Flow Regulator,
37.9/10
CURRENT amp
FLOW lpm/gpm
.1
34.1/9
22.7/6
18.9/5
11.4/3
3.8/1
7.5/2
15.1/4
26.5/7
30.2/8
.2 .3 .4 .5 .6 .7 .8 .9 1.0
Flow vs. Current (207 bar/3000 psi Load)
PV70-33B with EC10-40
11 bar/160 psi spring ——
5.5 bar/80 psi spring - - - -
2.8 bar/40 psi spring • • • • •
100 Hz Dither
37.9/10
FLOW lpm/gpm
34.1/9
22.7/6
18.9/5
11.4/3
3.8/1
7.5/2
15.1/4
26.5/7
30.2/8
CURRENT amp
.1 .2 .3 .4 .5 .6 .7 .8 .9 1.0
Flow vs. Current (207 bar/3000 psi Load)
PV70-33C with EC10-40
11 bar/160 psi spring ——
5.5 bar/80 psi spring - - - -
2.8 bar/40 psi spring • • • • •
100 Hz Dither
37.9/10
CURRENT amp
FLOW lpm/gpm
Flow vs. Current (207 bar/3000 psi Load)
PV70-33A with EC10-40
11 bar/160 psi spring ——
5.5 bar/80 psi spring - - - -
2.8 bar/40 psi spring • • • • •
100 Hz Dither
.1
34.1/9
22.7/6
18.9/5
11.4/3
3.8/1
7.5/2
15.1/4
26.5/7
30.2/8
.2 .3 .4 .5 .6 .7 .8 .9 1.0
Priority Port Flow Delivered Out Port ➁:
PERFORMANCE CURVES
24 Volt coil used; 130 Hz dither; PWM controller
DESCRIPTION
A pressure-compensated electrically-variable three-port fl ow regulator that is a priority
(bypass) type control. This combination valve uses a PV70-33x proportional cartridge
and an EC10-40 compensator.
OPERATION
The PFR70-33x-F series will bypass all fl ow out port ➂ when de-energized at the
pressure compensator spring value. When energized, this proportional valve/com-
pensator package will increase and regulate fl ow out of port
➁, regardless of system
working pressure, with an increasing current applied to the solenoid.
FEATURES
• Excellent linearity and hysteresis.
• Optional control orifi ce sizes.
• Hardened spool and cage for long life.
• Optional coil voltages and terminations.
• Effi cient wet armature construction.
RATINGS
Operating Pressure: 207 bar (3000 psi)
Pressure Rise: Pressure at
➀ begins to rise higher than the compensating pressure
differential when bypass fl ow exceeds 26.5 lpm (7 gpm).
Internal Leakage: 410 cc/min. (25 cu. in./min.) fully closed at 207 bar (3000 psi) out
port ➁.
Electrical: 2 standard voltage ratings
Operation of Manual Override:
To Engage: Turn clockwise approximately 1 turn to reach start point. Continue
another approximately 5 turns to full shift.
To Disengage: Turn counterclockwise approximately 6 turns until positive stop
is found.
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1; Filtration: See page 9.010.1
For 12 volt coils, double the current (amp) values shown.
37.9/10
41.4
600
LOAD bar/psi
FLOW lpm/gpm
Priority Port Flow Rate Loss Under Load
PV70-33B with EC10-40 Typical
11 bar/160 psi compensator —
5.5 bar/80 psi compensator - - -
2.8 bar/40 psi compensator • • •
82.8
1200
124.1
1800
165.5
2400
206.9
3000
34.1/9
30.2/8
22.7/6
15.1/4
7.5/2
26.5/7
18.9/5
11.4/3
3.8/1
Attention Manifold Designers:
To obtain these high fl ow capabilities
using proportional fl ow controls and
compensators, optimized cavity drillings
are required. Please consult factory.
ELECTRO-PROPORTIONAL VALVES—FLOW CONTROLS
HYDRAFORCE
.com
®
• Cartridges voltage interchangeable.
• Unitized, molded coil design.
• Coil waterproofi ng standard.
• Screw-in manual override option.
Threshold
Current (mA)
A & B C
Range Range
300 ± 70 360 ± 70
150 ± 35 180 ± 35
Coil
Voltage
12 VDC
24 VDC
Max. Control
Current (mA)
A & B C
Range Range
1500 ± 200 1400 ± 200
750 ± 100 700 ± 100
Blue rectangles are links to other catalog pages.