PV70-31 Proportional Flow Control Cartridge,
1
2
3
DESCRIPTION
A solenoid operated, electrically-variable, three-port, pressure-compensated, spool-
type, normally open when de-energized, proportional fl ow control valve. It can be used
as a priority-type fl ow regulator with pressure-compensated, regulated and bypass
ow. It can also be used as a restrictive-type two-way, pressure-compensated fl ow
regulator when the bypass line (port
) is blocked.
OPERATION
The PV70-31 will regulate fl ow out of port regardless of system working pressure.
With increasing current applied to the solenoid, the PV70-31 will decrease output fl ow.
Note: When used as a bypass fl ow control in applications where the priority fl ow port
will be blocked by external valving, bypass pressure drop will increase unless a small
amount of leakage is provided for the priority port. Consult factory.
Operation of Manual Override:
To Engage: Turn clockwise approximately 1 turn to reach start point. Continue
another approximately 5 turns to full shift.
To Disengage: Turn counterclockwise approximately 6 turns to positive stop.
FEATURES
Excellent linearity and hysteresis.
Hardened spool and cage for long life.
Optional coil voltages and terminations.
Effi cient wet armature construction.
RATINGS
Operating Pressure: Inlet: 240 bar (3500 psi); Ports and : 207 bar (3000 psi)
Regulated Flow Rate: Bypass Blocked, Range A: 26 lpm (7 gpm)
Bypass Blocked, Range B: 17 lpm (4.5 gpm)
Bypass Open, Range A: 30 lpm (8 gpm)
Bypass Open, Range B: 17 lpm (4.5 gpm)
Maximum Input Flow: Bypass Open, Range A: 50 lpm (13 gpm)
Bypass Open, Range B: 26 lpm (7 gpm)
Internal Leakage: 197 cc/min. (12 cu. in./min.) fully closed at 207 bar (3000 psi)
Electrical: 2 standard voltage ratings
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1.
Cavity: VC10-3; See page 9.110.1; Cavity Tool: CT10-3X-XX; See page 8.600.1
Seal Kit: SK10-3X-MM; See page 8.650.1 for seal kit options
and appropriate seals based on application temperature range.
USASI/ISO:
SYMBOLS
2.382.1
20
PERCENT OF MAX. CONTROL CURRENT
FLOW lpm/gpm
Flow vs. Current
207 bar/3000 psi; 12V Coil; 200 Hz PWM
32 cSt/150 ssu oil at 40°C
Range A, 2-Ported
Range A, 3-Ported
Range B, 2-Ported
Range B, 3-Ported
40 60 80 100
37.9/10
30.3/8
22.7/6
15.1/4
7.6/2
PERFORMANCE
Performance information continued
on following page.
Threshold Current
150 ± 70 mA
75 ± 35 mA
Coil Voltage
12 VDC
24 VDC
Max. Control Current
1400 ± 200 mA
700 ± 100 mA
ELECTRO-PROPORTIONAL VALVES—FLOW CONTROLS
HYDRAFORCE
.com
®
Cartridges voltage interchangeable.
Unitized, molded coil design.
Coil waterproofi ng standard.
Manual override option.
Recommended Electronic Controllers:
See page 2.001.1 or our Electronics catalog.
Blue rectangles are links to other catalog pages.
PV70-31
Normally Open
DIMENSIONS
2.382.2
C
I
E
C
R
O
F
A
R
D
Y
H
X
X
X
X
X
X
.
N
1.06
27.0
ACROSS FLATS
2.70
1.81
68.6
46.0
0.87 1.86
22.1 47.2
MILLIMETRE
INCH
1.13
28.6
ACROSS FLATS
18.8
53.8
66.5
34.5
7.1
50.86.4
63.5
31.8
31.8
1.36
2.00
0.25
2.62
2.12
0.74
2.50
1.25
1.25
0.28
2
3
1
TORQUE: 10–12 ft-lbs
(14–16 Nm)
TORQUE:
27 ft-lbs max.
(36.7 Nm)
1
2
44.1
1.74
3
.67
17.0
3.37
85.6
1.71
43.4
2.09
53.1
MANUAL
OVERRIDE
OPTION
"G"
MANUAL OVERRIDE
OPTION "M"
PERFORMANCE
(Continued)
69
1000
PRESSURE DROP bar/psi
FLOW lpm/gpm
Regulated Flow vs. Pressure Drop
2-Ported; Flow Range A
240 bar/3500 psi Inlet
12V Coil; 200 Hz PWM
32 cSt/150 ssu oil at 40°C
138
2000
207
3000
276
4000
37.9/10
30.3/8
22.7/6
15.1/4
7.6/2
0.0 AMP
0.5 AMP
0.8 AMP
1.1 AMP
69
1000
PRESSURE DROP bar/psi
FLOW lpm/gpm
Regulated Flow vs. Pressure Drop
2-Ported; Flow Range B
240 bar/3500 psi Inlet
12V Coil; 200 Hz PWM
32 cSt/150 ssu oil at 40°C
138
2000
207
3000
276
4000
18.9/5
3.8/1
11.4/3
22.7/6
15.1/4
7.6/2
0.0 AMP
0.5 AMP
0.7 AMP
0.9 AMP
1.1 AMP
®
HYDRAFORCE
HYDRAFORCE
.com
®
Porting
0 Cartridge
Only
6T SAE 6
8T SAE 8
2B 1/4 in. BSP*
3B 3/8 in. BSP*
Option(s)
None
(Blank)
Manual
Override M
Manual
Override
with Guard G
Cartridge: Weight: 0.19 kg. (0.42 lbs.)
Steel with hardened work surfaces.
Zinc-plated exposed surfaces. Buna
N O-rings and polyester elastomer
back-ups standard.
Standard Ported Body: Weight:
0.36 kg. (0.80 lbs.) Anodized high-
strength 6061 T6 aluminum alloy,
rated to 207 bar (3000 psi). Ductile
iron bodies available; dimensions
may differ. See page 8.010.1
70-Size “D” Coil: Weight: 0.32 kg.
(0.7 lbs.) Unitized thermoplastic
encapsulated, Class H high
temperature magnet-wire.
See page 3.200.7.
70-Size “E” Coil: Weight: 0.41 kg.
(0.9 lbs.) Fully encapsulated with
rugged external metal shell.
IP69K rated. See page 3.400.13.
MATERIALS
TO ORDER
PV70-31
__ __ - __ __ __ - __ - __ __ __ __
Flow Range
A
B
Voltage
0 Less Coil
12 12 VDC
24 24 VDC
Required. See
Performance
Curves.
Coils with internal diode are
available. Consult factory.
Seals
Buna N (Std.) N
Fluorocarbon V
*BSP Body;
U.K. Mfr. Only
Terminations D-Coil
DS Dual Spades
DG DIN 43650
DL Leadwires (2)
DL/W Leads w/Weatherpak
®
Connectors
Terminations E-Coil
IP69K Rated
ER Deutsch DT04-2P
EY Metri-Pack
®
150
Blue rectangles are links to other catalog pages.